Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01665261
Other study ID # KY2011-366-1
Secondary ID
Status Completed
Phase N/A
First received August 9, 2012
Last updated March 10, 2015
Start date July 2012
Est. completion date February 2013

Study information

Verified date March 2015
Source Children's Hospital of Fudan University
Contact n/a
Is FDA regulated No
Health authority China: Ministry of Health
Study type Observational

Clinical Trial Summary

The purpose of this study is to test the accuracy of 7 indicators in screening congenital heart defects (CHD) in all newborns (symptomatic or asymptomatic) to determine whether these indicators could be applied in the nationwide newborn CHD screening. The investigator's hypothesis is that 7 indicators are effective in neonate CHD screening with the acceptable accuracy.


Description:

Congenital heart defects (CHD) are among the most common major congenital anomalies, and they occur worldwide with an incidence of about 8-12/1,000 live births , Most of these defects are mild or moderate. They either do not need treatment or treatment is needed only after infancy. Other defects are severe and require early treatment in infancy, which are the primary objectives of screening, because they are at risk of adverse or irreversible outcomes as a consequence of congenital heart defects. However, about half the neonates in the nursery have no distinctive clinical signs (symptoms, abnormal murmurs or cyanosis).So it's necessary to develop a screening strategy for neonatologist and pediatrician, especially physicians in community. Screening strategy in our study consists of 7 indicators: Family history of CHD, tachypnea, heart murmurs(≥ 2 grade), cyanosis, other non-cardiac malformations,special face feature(relating to chromosomal or non-chromosomal syndromes), subnormal Pulse Oximetry reading (Oxygen saturation of less than 95% in either limb or more than 3% difference)。The newborn babies with any of these 7 indicators positive will be considered positive-screened and echocardiography will performed.

The whole study (screening for CHDs with 7 indicators and performing the echocardiography for diagnosis) will be conducted by one single investigator (Quming Zhao from Children's Hospital of Fudan University). The new generation Pulse Oximetry has been proved to have low intraobserver and interobserver variability, but the interobserver variability in clinical evaluation (especially murmurs and cyanosis) remain unknown, the investigator will also assess the interobserver variability by comparing Quming Zhao and other two pediatricians (from the participating Hospital)(blind to each other).


Recruitment information / eligibility

Status Completed
Enrollment 6730
Est. completion date February 2013
Est. primary completion date September 2012
Accepts healthy volunteers No
Gender Both
Age group N/A to 72 Hours
Eligibility Inclusion Criteria:

- all consecutive live newborn infants

- between 6-72hours of age

Exclusion Criteria:

- declining the screening;

- early discharge before the screening;

- missing

Study Design

Observational Model: Cohort, Time Perspective: Prospective


Locations

Country Name City State
China Songjiang District Central Hospital ShangHai Shanghai
China Songjiang Maternal and Child Health Hospital Shanghai Shanghai

Sponsors (1)

Lead Sponsor Collaborator
Children's Hospital of Fudan University

Country where clinical trial is conducted

China, 

References & Publications (3)

de-Wahl Granelli A, Wennergren M, Sandberg K, Mellander M, Bejlum C, Inganäs L, Eriksson M, Segerdahl N, Agren A, Ekman-Joelsson BM, Sunnegårdh J, Verdicchio M, Ostman-Smith I. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009 Jan 8;338:a3037. doi: 10.1136/bmj.a3037. — View Citation

Ewer AK, Furmston AT, Middleton LJ, Deeks JJ, Daniels JP, Pattison HM, Powell R, Roberts TE, Barton P, Auguste P, Bhoyar A, Thangaratinam S, Tonks AM, Satodia P, Deshpande S, Kumararatne B, Sivakumar S, Mupanemunda R, Khan KS. Pulse oximetry as a screening test for congenital heart defects in newborn infants: a test accuracy study with evaluation of acceptability and cost-effectiveness. Health Technol Assess. 2012;16(2):v-xiii, 1-184. doi: 10.3310/hta16020. — View Citation

Mahle WT, Newburger JW, Matherne GP, Smith FC, Hoke TR, Koppel R, Gidding SS, Beekman RH 3rd, Grosse SD; American Heart Association Congenital Heart Defects Committee of the Council on Cardiovascular Disease in the Young, Council on Cardiovascular Nursing, and Interdisciplinary Council on Quality of Care and Outcomes Research; American Academy of Pediatrics Section on Cardiology and Cardiac Surgery, and Committee on Fetus and Newborn. Role of pulse oximetry in examining newborns for congenital heart disease: a scientific statement from the American Heart Association and American Academy of Pediatrics. Circulation. 2009 Aug 4;120(5):447-58. doi: 10.1161/CIRCULATIONAHA.109.192576. Epub 2009 Jul 6. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Diagnostic accuracy of the 7 indicators for detection of all CHDs and major CHDs Sensitivity, specificity, negative and positive predictive value, negative and positive likelihood ratio of 7 indicators for the detection of all CHDs and major CHDs as gold standard the echocardiography. The goldstandard for CHD diagnosis is the echocardiography performed within 1 hour from the screening completed. No
See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Recruiting NCT04992793 - Paediatric Brain Injury Following Cardiac Interventions
Recruiting NCT05213598 - Fontan Associated Liver Disease and the Evaluation of Biomarkers for Disease Severity Assessment
Completed NCT04136379 - Comparison of Home and Standard Clinic Monitoring of INR in Patients With CHD
Completed NCT04814888 - 3D Airway Model for Pediatric Patients
Recruiting NCT04920643 - High-exchange ULTrafiltration to Enhance Recovery After Pediatric Cardiac Surgery N/A
Completed NCT05934578 - Lymphatic Function in Patients With Fontan Circulation: Effect of Physical Training N/A
Recruiting NCT06041685 - Effect of Local Warming for Arterial Catheterization in Pediatric Anesthesia N/A
Recruiting NCT05902013 - Video Laryngoscopy Versus Direct Laryngoscopy for Nasotracheal Intubation N/A
Not yet recruiting NCT05687292 - Application of a Clinical Decision Support System to Reduce Mechanical Ventilation Duration After Cardiac Surgery
Not yet recruiting NCT05524324 - Cardiac Resynchronization Therapy in Adult Congenital Heart Disease With Systemic Right Ventricle: RIGHT-CRT N/A
Completed NCT02746029 - Cardiac Murmurs in Children: Predictive Value of Cardiac Markers
Completed NCT02537392 - Multi-micronutrient Supplementation During Peri-conception and Congenital Heart Disease N/A
Completed NCT03119090 - Fontan Imaging Biomarkers (FIB) Study
Recruiting NCT02258724 - Swiss National Registry of Grown up Congenital Heart Disease Patients
Completed NCT01966237 - Milrinone Pharmacokinetics and Acute Kidney Injury
Terminated NCT02046135 - Sodium Bicarbonate to Prevent Acute Kidney Injury in Children Undergoing Cardiac Surgery Phase 2
Recruiting NCT01184404 - Bosentan Improves Clinical Outcome of Adults With Congenital Heart Disease or Mitral Valve Lesions Who Undergo CArdiac Surgery N/A
Completed NCT01548950 - Drug Therapy and Surgery in Congenital Heart Disease With Pulmonary Hypertension N/A
Completed NCT01821287 - Nutritional Failure in Infants With Single Ventricle Congenital Heart Disease N/A