Clinical Trials Logo

Clinical Trial Summary

Background Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right ventricular outflow tract dysfunction in patients with congenital heart diseases. Long-term outcomes following this procedure using the new generation SAPIEN 3 valve is little known. Purpose This study aims to report mid-term outcomes in a large cohort of patients who had TPVI using the SAPIEN 3 valve. Methods We designed a retrospective multicentre observational registry of patients undergoing TPVI with the SAPIEN 3 valve across centres in Europe, Middle-east and Canada. Patient-related, procedural, and mid-term outcomes data will be characterized.


Clinical Trial Description

1. INTRODUCTION Percutaneous pulmonary valve implantation (PPVI) is effective to treat right ventricle outflow (RVOT) dysfunction. First reported by Bonhoeffer et al. in 2000, PPVI extends the lifespan of an existing RVOT revision and delays the need for repeat surgical intervention. First limited to patients with dysfunctional right-ventricle to pulmonary artery conduit, its feasibility was extended to patients with bioprosthesis, small expandable conduits and native RVOT. In select patients, it is nowadays a first-line approach to PV replacement. With longer follow-up, some issues arose such as the incidence of infective endocarditis (IE). It remains highly debatable if the risk of IE varied according to the type of implanted valve. Tricuspid valve injuries were also reported while advancing a valve without covering along the right heart cavities. However, most of the current evidence has been gathered using the early generation Melody (Medtronic Inc., Minneapolis, MN) or Edwards SAPIEN valves (Edwards Lifesciences, Irvine, CA). Ongoing prosthesis improvement programmes have led to the availability of the SAPIEN 3 (S3), a bovine pericardial valve mounted on a fatigue-resistant cobalt chromium alloy stent with inclusion of an outer polyethylene terephthalate skirt, available in 20, 23, 26 and 29 mm in diameter. First implanted in 2014 in pulmonary position and subsequently described in preliminary multicentre reports, PPVI with the S3 valve appears to be safe and feasible in a wide range of patients with congenital heart defects, including those with large native RVOT. Use of this valve and its smooth deflectable Commander delivery system has been shown to facilitate PPVI, together with the use of a long introducer delivery sheath. The procedures resulted in good short-term haemodynamic and functional outcomes, with very few adverse events, paving the way for worldwide implantation of the S3 valve in the pulmonic position. Furthermore, while prestenting is systematically recommended before implanting a Melody valve to decrease the risk of stent fracture during follow-up, S3 design and radial strength resulted in a modification of implantation method with decreased prestenting indications. However, positive safety and efficacy outcomes remains to be demonstrated over the longer term. There is currently little formal data on S3 implantation in the pulmonic position over few months. The objective of the present multicentre registry analysis was to explore safety, feasibility, and haemodynamic outcomes of PPVI using the S3 to up to five years. 2. METHODS We designed a retrospective multicentre cohort study including all consecutives PPVI of a S3 valve between 2014 and decembre 2021 in European, Canadian and middle-east centres. The study was approved by an ethical committees (GERM IRB 00012157, reference 543, 27 October 2021) and performed in accordance with the Declaration of Helsinki and its amendments. 2.1 Centres These centres are situated in Europe (France, United-Kingdom, Germany, Italy, Spain, Switzerland, Poland), the Middle East (Turkey, Israel), and Canada. No minimum requirements pertaining to number of implants or operator experience are specified. 2.2 Patients Inclusion criteria were a clinical indication for PPVI and a prior implantation of the S3 in the pulmonic position, with the decision to perform the procedure taken independently. So as to represent the broadest possible spectrum of patients undergoing PPVI, no further inclusion/exclusion criteria were stipulated. PPVI is usually indicated in symptomatic patients or those with evidence of RV or left ventricular systolic dysfunction, severe RV enlargement with an indexed RV end-diastolic volume of greater than 160 mL/m2, or an indexed RV end-systolic volume of greater than 80 mL/m2 and those with decreases in exercise capacity. PPVI was performed using SAPIEN 3 valve in all cases. The SAPIEN 3 valve is characterized by a trileaflet valve crafted from bovine pericardium treated with the same ThermaFix process as Carpentier-Edwards surgical valves. The valve is sutured to a cobalt-chromium stent frame with optimized cell design to minimize profile and improve radial strength. Additionally, the SAPIEN 3 has an outer polyethylene terephthalate skirt which decreases the incidence of paravalvular leak. The SAPIEN 3 valve is available in 20- 23-, 26-, and 29-mm sizes and is introduced using the Commander delivery system (14 and 16-Fr expandable sheaths). It has obtained CE mark in 2021. 2.3 Data collection Given the wide range of patients represented in the study, the Pulmonic S3 electronic case report form (eCRF) was designed to accommodate the broadest possible spectrum of clinical settings in which PPVI may be indicated. As such, the data collected reflects the site's standard procedures, including but not limited to physical assessments, ECGs, laboratory testing, and cardiac imaging. Data entry was performed by the treating physician or study nurse through retrospective appraisal of medical records. Data regarding patient demographics, underlying diagnoses and RVOT anatomies were collected for the period prior to PPVI, with peri-procedural details and outcomes also documented. Follow-up time points for the assessment of adverse events and functional outcomes were 30 days, six months, one and two years. Data were subjected to regular automatic and manual checks for plausibility and completeness. 2.4 Outcomes and definitions Key haemodynamic and functional outcomes included changes in the peak systolic gradient over RVOT; degree of pulmonary regurgitation following PPVI. Feasibility was assessed according to procedural success (defined as successful implantation of a single valve at the intended location and retrieval of the delivery catheter), while safety outcomes included the rates of periprocedural technical complications (device malfunction [defined as failure to meet performance specifications or otherwise perform as expected]; valve dislocation requiring surgical intervention; and stent dislocation), periprocedural adverse events (significant bleeding; arrhythmia requiring pacing, drugs or cardioversion; conduit/RVOT rupture requiring emergency stenting or surgery; significant neurological impairment [based on clinical assessment; coronary compression; myocardial infarction; pulmonary embolism; and periprocedural death). 2.5 Statistics Data are presented as descriptive data summaries. Categorical variables are expressed as absolute numbers and frequencies (%), while continuous variables are expressed as means with standard deviations (SD) and minimum-maximum data ranges. 3. RESULTS 3.1 Patient characteristics will be displayed 3.2 Procedural characteristics will be displayed 3.3 Periprocedural outcomes and safety will be reported - What is known: Percutaneous pulmonary valve implantation is safe and effective to treat right ventricle outflow tract dysfunction in patients with congenital heart diseases A wide spectrum of devices are being used currently. The new-generation SAPIEN 3 valve has recently been labelled for percutaneous pulmonary valve implantation. • What the Study will Add: SAPIEN 3 Three and Five-years freedom from secondary pulmonary valve replacement will be reported SAPIEN 3 Annualized Incidence of infective endocarditis will be reported. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05264181
Study type Observational
Source Centre Chirurgical Marie Lannelongue
Contact Sebastien Hascoet, MD, PhD
Phone 0140942429
Email s.hascoet@ghpsj.fr
Status Recruiting
Phase
Start date September 1, 2021
Completion date August 1, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Recruiting NCT04992793 - Paediatric Brain Injury Following Cardiac Interventions
Recruiting NCT05213598 - Fontan Associated Liver Disease and the Evaluation of Biomarkers for Disease Severity Assessment
Completed NCT04136379 - Comparison of Home and Standard Clinic Monitoring of INR in Patients With CHD
Completed NCT04814888 - 3D Airway Model for Pediatric Patients
Recruiting NCT04920643 - High-exchange ULTrafiltration to Enhance Recovery After Pediatric Cardiac Surgery N/A
Completed NCT05934578 - Lymphatic Function in Patients With Fontan Circulation: Effect of Physical Training N/A
Recruiting NCT06041685 - Effect of Local Warming for Arterial Catheterization in Pediatric Anesthesia N/A
Recruiting NCT05902013 - Video Laryngoscopy Versus Direct Laryngoscopy for Nasotracheal Intubation N/A
Not yet recruiting NCT05687292 - Application of a Clinical Decision Support System to Reduce Mechanical Ventilation Duration After Cardiac Surgery
Not yet recruiting NCT05524324 - Cardiac Resynchronization Therapy in Adult Congenital Heart Disease With Systemic Right Ventricle: RIGHT-CRT N/A
Completed NCT02746029 - Cardiac Murmurs in Children: Predictive Value of Cardiac Markers
Completed NCT03119090 - Fontan Imaging Biomarkers (FIB) Study
Completed NCT02537392 - Multi-micronutrient Supplementation During Peri-conception and Congenital Heart Disease N/A
Recruiting NCT02258724 - Swiss National Registry of Grown up Congenital Heart Disease Patients
Completed NCT01966237 - Milrinone Pharmacokinetics and Acute Kidney Injury
Terminated NCT02046135 - Sodium Bicarbonate to Prevent Acute Kidney Injury in Children Undergoing Cardiac Surgery Phase 2
Recruiting NCT01184404 - Bosentan Improves Clinical Outcome of Adults With Congenital Heart Disease or Mitral Valve Lesions Who Undergo CArdiac Surgery N/A
Completed NCT01548950 - Drug Therapy and Surgery in Congenital Heart Disease With Pulmonary Hypertension N/A
Completed NCT01178710 - Effect of Simvastatin on Cardiac Function N/A