The purpose of this study is to make the proof of concept and to evaluate the safety of fetoscopic endoluminal tracheal occlusion (FETO) using Smart-TO device in fetuses with congenital diaphragmatic hernia and moderate to severe pulmonary hypoplasia


Clinical Trial Description

Congenital diaphragmatic hernia (CDH) leads to lung hypoplasia and impaired lung vasculature. Fetal lung growth may be stimulated by fetal endoscopic tracheal occlusion (FETO). In severe CDH, FETO may improve survival. In the moderate cases, the prematurity induced by the plug-unplug strategy limits the benefit from the lung growth induced by tracheal occlusion. One of the main drawbacks of FETO is the need for in-utero reversal of tracheal occlusion by the balloon, as the current procedure involves re-establishment of patent airways either electively at 34 weeks' gestation or earlier if required, ideally at least 24 h before birth. Unfortunately, removal of the balloon is a difficult, invasive, and risky procedure. Furthermore, it requires a specialist team to be able to reverse the occlusion at all times. As a result, it is recommended that the patient stays close to a FETO center during the whole duration of the occlusion, which may limit the acceptability of FETO. The Smart-TO balloon allows an easy, remotely controlled, and non-invasive reversal occlusion, so it allows to overcome issues related to the airway reestablishment. The technology solution is based on a magnetic valve that opens under the influence of the peripheral magnetic field around a magnetic resonance (MR) scanner. The opening of the valve induces the deflation of the balloon, which is then washed out by the fluid coming out from the lungs. The purpose of this study is to make the proof of concept and to evaluate the safety of fetoscopic endoluminal tracheal occlusion (FETO) using Smart-TO device in fetuses with congenital diaphragmatic hernia and moderate to severe pulmonary hypoplasia. Secondary objectives include evaluation of prematurity, preterm premature rupture of membranes, lung growth, and survival at discharge in case of FETO with Smart-TO balloon. FETO with Smart-TO balloon will be performed between 27 and 31wks + 6 days depending on the severity of pulmonary hypoplasia, according to the same technique that is used with the balloon usually used for FETO procedure. The unplug procedure will be performed between 34 and 34wks + 6 days or earlier if required. The patient will be asked to make a peripheral course around the MR scanner in order to open the magnetic valve and induce the deflation of the balloon. Ultrasound scan will be performed before and after the unplug procedure, in order to check the balloon did not deflate spontaneously at the time of the unplug, and to check the balloon deflates thanks to the magnetic fringe field of the MR scan. Expelling of the Smart-TO balloon outside the airways will be check at birth by a thorax X-ray. Patients will be monitored during the whole duration of the study so serious unexpected or adverse reactions can be recorded. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04931212
Study type Interventional
Source Assistance Publique - Hôpitaux de Paris
Contact Alexandra BENACHI, MD, PhD
Phone 01 45 37 44 76
Email alexandra.benachi@aphp.fr
Status Recruiting
Phase N/A
Start date August 4, 2021
Completion date October 2024

See also
  Status Clinical Trial Phase
Recruiting NCT05100693 - Smart Removal for Congenital Diaphragmatic Hernia N/A
Recruiting NCT05450653 - Trial of FETO for Severe Congenital Diaphragmatic Hernia N/A
Terminated NCT04140669 - Automated Myocardial Performance Index Using Samsung HERA W10
Recruiting NCT05201144 - A Trial of Phosphodiesterase-5 Inhibitor in Neonatal Congenital Diaphragmatic Hernia (TOP-CDH) Phase 2
Recruiting NCT04429750 - Intact Cord Resuscitation in CDH N/A
Recruiting NCT03750266 - 3D Animation and Models to Aid Management of Fetal CDH
Completed NCT01243229 - Genetic Analysis of Congenital Diaphragmatic Disorders
Recruiting NCT04583644 - Pilot Trial of Fetoscopic Endoluminal Tracheal Occlusion (FETO) in Severe Left Congenital Diaphragmatic Hernia (CDH) N/A
Completed NCT03314233 - Delayed Cord Clamping for Congenital Diaphragmatic Hernia N/A
Recruiting NCT04114578 - Exploratory Observational Prospective Study in Neonatal and Pediatric Congenital Diaphragmatic Hernia
Completed NCT03666767 - Management and Outcomes of Congenital Anomalies in Low-, Middle- and High-Income Countries
Recruiting NCT02986087 - Feto-Endoscopic Tracheal Occlusion (FETO) for Left Congenital Diaphragmatic Hernia N/A
Recruiting NCT03674372 - Fetoscopic Endoluminal Tracheal Occlusion N/A
Active, not recruiting NCT05839340 - Neurally Adjusted Ventilatory Assist for Neonates With Congenital Diaphragmatic Hernias N/A
Enrolling by invitation NCT05962346 - Fetal Endoscopic Tracheal Occlusion for Congenital Diaphragmatic Hernia N/A
Withdrawn NCT04186039 - Functional Evaluation of the Fetal Lung by Functional Magnetic Resonance Imaging - Blood Oxygenation Level Dependent (MRI-BOLD), in Congenital Diaphragmatic and Parietal Malformations N/A
Unknown status NCT01302977 - Fetal Tracheal Occlusion in Severe Diaphragmatic Hernia: a Randomized Trial Phase 2
Recruiting NCT03179371 - Proteomic Profiling for Congenital Diaphragmatic Hernia
Recruiting NCT03138863 - Fetal Endoscopic Tracheal Occlusion for Congenital Diaphragmatic Hernia (FETO) N/A
Active, not recruiting NCT04484441 - Maternal-fetal Immune Responses to Fetal Surgery