Clinical Trials Logo

Clinical Trial Details — Status: Enrolling by invitation

Administrative data

NCT number NCT03461978
Other study ID # OPHT - 010616
Secondary ID
Status Enrolling by invitation
Phase N/A
First received
Last updated
Start date July 12, 2017
Est. completion date October 2023

Study information

Verified date April 2022
Source Medical University of Vienna
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The development of optical coherence tomography (OCT) and its application for in vivo imaging has opened entirely new opportunities in ophthalmology. The technology allows for both noninvasive visualization of the morphology and measurement of functional parameters within ocular tissues to a depth of a few millimetres even in nontransparent media. Until now the resolution of commercially available OCT systems is, however, much lower than that provided by light microscopy. Recently, an ultrahigh-resolution OCT system was developed by our group providing resolutions of 1.7 and 17 µm in axial and lateral direction, respectively. This axial resolution is about four times better than that provided by standard OCT systems. It allows to perform in vivo imaging with a resolution close to biopsy of tissue and to visualize structures of the anterior eye segment with a remarkable richness of detail. The prototype was applied for in vivo imaging of the cornea including the precorneal tear film. The goal of the planned pilot study is to apply this innovative imaging modality for visualization of the ultrastructure of the different parts of the anterior eye segment structures in diseased subjects, as well as in patients who underwent minimally invasive glaucoma surgery (MIGS). The obtained in vivo cross sectional images and three-dimensional data sets are hoped for contributing to the knowledge about the anatomy and physiology of the corresponding tissues. This could allow for a better interpretation of clinical features and findings obtained in slit lamp examination.


Recruitment information / eligibility

Status Enrolling by invitation
Enrollment 60
Est. completion date October 2023
Est. primary completion date September 2023
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - For patients with meibomian gland dysfunction (MGD): MGD as evidenced by clinical features and gland expression (MGD Grading Scheme, Appendix I (Opitz, Harthan et al. 2015)) - For cataract patients: Cataract as evidenced from slit lamp examination, stage range between NII-NIII, CII-CIV, PII-PIII according to The Lens Opacity Classification System II (LOCS II) (Chylack, Leske et al. 1989) (Appendix II) - For patients after minimally invasive glaucoma surgery (MIGS): Patients with history of MIGS secondary to glaucoma - For patients with demodicosis: Demodicosis as evidenced from slit lamp examination and presence of Demodex confirmed by microscopic examination of the eye lashes (Liu, Sheha et al. 2010) - For patients with conjunctival pathologies (cyst, naevus, pterygium): Conjunctival pathologies with a clinical diagnosis of the respective - For patients with Acanthamoeba keratitis: Acanthamoeba keratitis as evidenced from slit lamp examination and confirmed by polymerase chain reaction (PCR) analysis of corneal epithelial and tear samples and culture isolation (Lehmann, Green et al. 1998) - For aniridia patients: Anirida as evidenced from slit lamp examination Exclusion Criteria: - Presence of any abnormalities preventing reliable measurements as judged by the investigator - Pregnancy, planned pregnancy or lactating

Study Design


Intervention

Device:
Ultrahigh resolution Spectral Domain OCT
A spectrometer based ultrahigh resolution Spectral Domain OCT (SDOCT) system operating at 800 nm for the anterior chamber will be employed in the present study. The spectrum of the Ti:Sapphire laser light source is centered at 800 nm. With a full width at half maximum bandwidth of 170 nm, the axial resolution is 1.3 µm in the cornea. The transverse resolution of the employed OCT system is 21 µm at the front surface of the cornea. For measurement, patients will place their head in a modified slit lamp head rest. During the measurement period, patients will be asked to look straight forward onto an internal fixation target and to avoid blinking. Different scattering patterns, e.g. raster, circular and spiral scans will be employed.

Locations

Country Name City State
Austria Medical University Vienna, Department of Clnical Pharmacology Vienna

Sponsors (1)

Lead Sponsor Collaborator
Medical University of Vienna

Country where clinical trial is conducted

Austria, 

References & Publications (3)

Drexler W, Liu M, Kumar A, Kamali T, Unterhuber A, Leitgeb RA. Optical coherence tomography today: speed, contrast, and multimodality. J Biomed Opt. 2014;19(7):071412. doi: 10.1117/1.JBO.19.7.071412. Review. — View Citation

Werkmeister RM, Alex A, Kaya S, Unterhuber A, Hofer B, Riedl J, Bronhagl M, Vietauer M, Schmidl D, Schmoll T, Garhöfer G, Drexler W, Leitgeb RA, Groeschl M, Schmetterer L. Measurement of tear film thickness using ultrahigh-resolution optical coherence tomography. Invest Ophthalmol Vis Sci. 2013 Aug 15;54(8):5578-83. doi: 10.1167/iovs.13-11920. — View Citation

Wojtkowski M, Kaluzny B, Zawadzki RJ. New directions in ophthalmic optical coherence tomography. Optom Vis Sci. 2012 May;89(5):524-42. doi: 10.1097/OPX.0b013e31824eecb2. Review. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Measurement of corneal layers in ultrahigh-resolution OCT Measurement of corneal layers in ultrahigh-resolution OCT of eyes with pathological changes in structures of the anterior eye segment. 60 minutes
See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A