Clinical Trials Logo

Clinical Trial Summary

Arterial stiffness is an important marker of cardiovascular risk. It is measured by pulse wave velocity. The reference device to measure pulse wave velocity is the Sphygmocor which uses applanation tonometry. It is used in adults and children. An easier method called pOpmètre using saturation sensors is validated in adults but not in children. The objective of this study is to compare the pulse wave velocity values measured with the pOpmètre® with those of the SphygmoCor® to validate the pOpmètre in children between 4 and 8 years old.


Clinical Trial Description

Prematurity is associated with an increased risk of developing cardio-vascular diseases in adulthood : a low birth weight linked to prematurity is correlated to a higher coronary disease mortality rate, a higher blood pressure level in adulthood, to abnormal glucose metabolism regulation, and to signs of nephron reduction. An independent marker of cardiovascular risk is arterial stiffness: it is associated with a higher risk of major cardiovascular events including stroke, acute coronary syndrome and complications of end-stage renal disease. It is measured by pulse wave velocity which is the gold standard in adulthood. Pulse wave velocity is also correlated to cardiovascular risk in childhood. National cohort EPIPAGE II is made of 4290 premature babies born in 2011. A study is scheduled at 5 years old and a half including a medical examination and a neuropsychological evaluation. An ancillary study lengthening medical consultation for 15 minutes is scheduled with 750 to 1000 of these children for a more precise vascular evaluation including pulse wave velocity. Different methods can be used to measure pulse wave velocity in children: these include applanation tonometry devices such as the SphygmoCor ® system. Its reference values are well known in adulthood and were determined more recently in childhood. It is the reference device but it is expensive, can be used only in expert health centres and time of measurement is long. In children, an easier-to-use and faster device would be more advantageous. The pOpmètre® uses 2 distal oxygen saturation sensors on finger and toe to deduce pulse wave velocity. This device has already been validated in adults. The aim of this study is to validate the pOpmètre in children between 4 and 8 years old. In that purpose, patients are installed in the supine position, at rest. The child's mensurations are measured. The two pOpmètre sensors are put on finger and toe. Blood pressure is measured by an armband on the right limb. Then another armband is put around the thigh and a tonometer is applied on the right carotid which allows pulse wave velocity measuring by the Sphygmocor. Pulse wave velocity is measured with the pOpmètre using the time delay between finger pulse signal and toe pulse signal. The values got with the two devices are compared using a Bland and Altman graph. The pOpmètre is considered to be validated if the 95% confidence interval of the bias is included between -0.5 m/sec and 0.5 m/sec that is about 10% of the normal value at that age (5.0 m/s +/-0.13). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02991703
Study type Interventional
Source Nantes University Hospital
Contact
Status Completed
Phase N/A
Start date December 14, 2016
Completion date July 6, 2017

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Recruiting NCT05650307 - CV Imaging of Metabolic Interventions
Recruiting NCT04515303 - Digital Intervention Participation in DASH
Completed NCT04056208 - Pistachios Blood Sugar Control, Heart and Gut Health Phase 2
Recruiting NCT04417387 - The Genetics and Vascular Health Check Study (GENVASC) Aims to Help Determine Whether Gathering Genetic Information Can Improve the Prediction of Risk of Coronary Artery Disease (CAD)
Not yet recruiting NCT06211361 - Cardiac Rehabilitation Program in Patients With Cardiovascular Disease N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04514445 - The BRAVE Study- The Identification of Genetic Variants Associated With Bicuspid Aortic Valve Using a Combination of Case-control and Family-based Approaches.
Enrolling by invitation NCT04253054 - Chinese Multi-provincial Cohort Study-Beijing Project
Completed NCT03273972 - INvestigating the Lowest Threshold of Vascular bENefits From LDL Lowering With a PCSK9 InhibiTor in healthY Volunteers N/A
Completed NCT03680638 - The Effect of Antioxidants on Skin Blood Flow During Local Heating Phase 1
Recruiting NCT04843891 - Evaluation of PET Probe [64]Cu-Macrin in Cardiovascular Disease, Cancer and Sarcoidosis. Phase 1
Completed NCT04083872 - Clinical Study to Investigate the Pharmacokinetic Profiles and Safety of Highdose CKD-385 in Healthy Volunteers(Fasting) Phase 1
Completed NCT04083846 - Clinical Study to Investigate the Pharmacokinetic Profiles and Safety of High-dose CKD-385 in Healthy Volunteers(Fed) Phase 1
Completed NCT03466333 - Postnatal Enalapril to Improve Cardiovascular fUnction Following Preterm Pre-eclampsia Phase 2
Completed NCT03693365 - Fluid Responsiveness Tested by the Effective Pulmonary Blood Flow During a Positive End-expiratory Trial
Completed NCT03619148 - The Incidence of Respiratory Symptoms Associated With the Use of HFNO N/A
Completed NCT04082585 - Total Health Improvement Program Research Project
Completed NCT05132998 - Impact of a Comprehensive Cardiac Rehabilitation Program Framework Among High Cardiovascular Risk Cancer Survivors N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)