Background It is known from previous research that in patients with complete AV (atrioventricular) block and pacemaker stimulation stroke volume and cardiac output are higher with AV-synchronous than with AV-dyssynchronous pacing. However, the extent to which patients profited from AV-synchronous stimulation varied substantially.

Aim of the study Aim of this study is to systematically analyze the impact of diastolic function and other echo parameters on the difference of stroke volumes/cardiac output between AV-synchronous and AV-dyssynchronous pacing modes.

Methods Patients fulfilling the entry criteria will be enrolled (two-chamber pacemaker of any vendor eligible) in this monocentric, prospective, interventional study. Baseline data will be collected with a standardized questionnaire. During an echo examination, parameters of diastolic, systolic and atrial function will be assessed. Then, the stroke volume/cardiac output will be measured twice in each patient, once with AV-synchronous and once with AV-dyssynchronous pacing. Therefore, each patient will represent their own control. It will be randomized (coin tossing) which stimulation mode is first and which is second (sonographer and patient will be blinded). Descriptive statistics will be applied and regression models will be fitted to explore the data.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT04068233
Study type Interventional
Source Kepler University Hospital
Contact
Status Completed
Phase N/A
Start date June 26, 2019
Completion date February 5, 2020

See also
  Status Clinical Trial Phase
Recruiting NCT04604886 - The Consistency of Cardiac Output Measured by Pulmonary Artery Catheter and LiDCO in Cardiac Surgical Patients N/A
Completed NCT04044157 - Cardiac Output in Children During Anesthesia
Not yet recruiting NCT01678066 - A Prospective Study to Bilaterally Compare a Non-Invasive Cardiac Output Monitor N/A
Completed NCT01001533 - Assess the Ability of Electrical Cardiometry to Trend Hemodynamic Variables During Dexmedetomidine Sedation N/A
Recruiting NCT04926220 - Dynamic Estimation of Cardiac Output in the Operating Room
Not yet recruiting NCT06007196 - Evaluation of Non-invasive Continuous Hemodynamic Measurement From Task Force CORE
Recruiting NCT05648279 - Personalized Hemodynamic Management in High-risk Major Abdominal Surgery N/A
Recruiting NCT06090396 - Non-invasive Cardiac Index in Children
Completed NCT05508711 - Comparability of Transesophageal Echocardiography and FloTrac/Vigileo System Three Different Positions
Completed NCT02438228 - Cardiac Output by Nine Different Pulse Contour Algorithms N/A
Completed NCT00996190 - Best Regimen for Phenylephrine Administration During Cesarean Section Phase 4
Withdrawn NCT00783679 - The Feasibility and Accuracy of Exhaled CO2 to Measure Cardiac Output in Ventilated Patients Without Tracheal Intubation N/A
Active, not recruiting NCT04465201 - The Smart Pump Study N/A
Completed NCT05779683 - Caretaker in the Cardiovascular Intensive Care Unit (CVICU)
Completed NCT04112719 - Assessing Effects of Lateral Tilt on Cardiac Output Using a Non-invasive Technique
Recruiting NCT02156856 - Stroke Volume Analysis During Aortic Valve Replacement Trial N/A
Recruiting NCT01781260 - Effect of Prone Position on Liver Blood Flow and Function N/A
Terminated NCT00920569 - Recirculation, Oxygenator Blood Volume and Cardiac Output Measurements During Extracorporeal Membrane Oxygenation N/A
Recruiting NCT06114147 - Cardiac Flow Measurements in Pregnant Women by Non Invasive Techniques N/A
Completed NCT05365113 - Comparison of Hemodynamic Effects of Two Modalities of Alveolar Recruitment Maneuvers in Major Abdominal Surgery Patients N/A