Clinical Trials Logo

Clinical Trial Summary

Using an investigational CT scanner which uses a new type of detector to capture X-rays, (a photon counting CT detector), the goal of this experimental study is to compare conventional CT images to CT images using the photon counting detector in patients undergoing CT scans for clinically indicated reasons. The main question it aims to answer is whether the images produced using the new detectors are superior in quality. Participants will undergo the clinically indicated CT images and the photon counting detector CT images of a limited area during the same examination time.


Clinical Trial Description

NIH develops new imaging techniques as one of its priorities for accelerating science, including methods for non-invasive patient assessments. Computed tomographic (CT) imaging is a mainstay of diagnostic imaging. The latest major technological advance is photon counting CT (PCCT) which uses a new x-ray detector that measures x-ray penetration of the body and the energy of each x-ray photon. NIH Clinical Center will use a prototype Siemens PCCT CounT systems built for clinical investigational use. The scanner can perform standard CT and PCCT imaging. In this protocol, NIH patients already enrolled in a clinical research protocol and who are referred to Radiology for diagnostic CT as part of that research may be enrolled in this study of PCCT. The diagnostic CT scan requested by their medical care team will be performed on the CounT scanner, providing the clinically indicated imaging, along with a single abbreviated PCCT exam of an organ or body part to support PCCT feasibility of the PCCT to provide better images in several small groups of patients with selected medical conditions. The data will be used to characterize quality of the PCCT images and to develop testable hypotheses and new diagnostic applications using PCCT capabilities. Current CT systems, such as the Siemens SOMATOM Flash, have two x-ray tubes, each paired with an x-ray detector that measures total x-ray penetration of the patient and uses that information to create the images. The CounT scanner is a modified version of the Flash in which one of the two standard detectors has been replaced with a PCCT detector. The two imaging modes for the CounT scanner are (i) standard detector study as in a Flash scanner and (ii) PCCT scan. The patient scan will thus include clinically indicated radiation exposure with the standard detector and research radiation over a limited field with the PCCT detector. The CounT system is sited at the Clinical Center under a CRADA (Cooperative research and development agreement) with Siemens Medical Solutions. Compared to current scanners, PCCT is expected to offer four major advantages: - lower radiation dose - greater spatial resolution - reduced imaging noise - x-ray energy discrimination As a translational development protocol, all imaging studies are open-label and data may be analyzed as they are collected. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03878134
Study type Interventional
Source National Institutes of Health Clinical Center (CC)
Contact
Status Completed
Phase N/A
Start date October 1, 2019
Completion date January 18, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT05346796 - Survivorship Plan HEalth REcord (SPHERE) Implementation Trial N/A
Recruiting NCT05094804 - A Study of OR2805, a Monoclonal Antibody Targeting CD163, Alone and in Combination With Anticancer Agents Phase 1/Phase 2
Completed NCT04867850 - Effect of Behavioral Nudges on Serious Illness Conversation Documentation N/A
Enrolling by invitation NCT04086251 - Remote Electronic Patient Monitoring in Oncology Patients N/A
Completed NCT01285037 - A Study of LY2801653 in Advanced Cancer Phase 1
Completed NCT00680992 - Study of Denosumab in Subjects With Giant Cell Tumor of Bone Phase 2
Completed NCT00062842 - Study of Irinotecan on a Weekly Schedule in Children Phase 1
Active, not recruiting NCT04548063 - Consent Forms in Cancer Research: Examining the Effect of Length on Readability N/A
Completed NCT04337203 - Shared Healthcare Actions and Reflections Electronic Systems in Survivorship N/A
Recruiting NCT04349293 - Ex-vivo Evaluation of the Reactivity of the Immune Infiltrate of Cancers to Treatments With Monoclonal Antibodies Targeting the Immunomodulatory Pathways N/A
Terminated NCT02866851 - Feasibility Study of Monitoring by Web-application on Cytopenia Related to Chemotherapy N/A
Active, not recruiting NCT05304988 - Development and Validation of the EFT for Adolescents With Cancer
Completed NCT04448041 - CRANE Feasibility Study: Nutritional Intervention for Patients Undergoing Cancer Surgery in Low- and Middle-Income Countries
Completed NCT00340522 - Childhood Cancer and Plexiform Neurofibroma Tissue Microarray for Molecular Target Screening and Clinical Drug Development
Recruiting NCT04843891 - Evaluation of PET Probe [64]Cu-Macrin in Cardiovascular Disease, Cancer and Sarcoidosis. Phase 1
Active, not recruiting NCT03844048 - An Extension Study of Venetoclax for Subjects Who Have Completed a Prior Venetoclax Clinical Trial Phase 3
Completed NCT03109041 - Initial Feasibility Study to Treat Resectable Pancreatic Cancer With a Planar LDR Source Phase 1
Completed NCT03167372 - Pilot Comparison of N-of-1 Trials of Light Therapy N/A
Terminated NCT01441115 - ECI301 and Radiation for Advanced or Metastatic Cancer Phase 1
Recruiting NCT06206785 - Resting Energy Expenditure in Palliative Cancer Patients