View clinical trials related to Bradycardia.
Filter by:Surgery of large cerebellopontine angle (CPA) tumors (>2 x 2 cm diameter), with compression of the pons exposes the patient to inadvertent parasympathetic nerve stimulation (IPNS) leading to bradycardia and asystole. The analgesia nociception index (ANI) monitor assesses the balance between analgesia and nociception through the detection of parasympathetic tone. ANI >80 generally denotes excessive analgesia (EA). The main objective of this study was to determine whether ANI values for IPNS are different or the same as ANI values for EA. This study also aims at calculating the number of patients with IPNS and EA during surgery of large CPA tumours.
The purpose of the study is to confirm the safety and the electrical performances of the XFINE passive pacing leads, for both right ventricular (RV) straight models and right atrial (RA) J-shape models, up to 12 months follow-up post implant.
When newborn babies are born without a heartbeat the clinical team has to provide breathing and chest compressions (what is call cardiopulmonary resuscitation) to the newborn baby. Cardiopulmonary resuscitation is an infrequent event in newborn babies (~1% of all deliveries), approximately one million newborn babies die annually due to lack of oxygen at birth causing being born without a heartbeat. Outcome studies of newborn babies receiving cardiopulmonary resuscitation in the delivery room have reported high rates of death and neurological impairment. This puts a heavy burden on health resources since these infants require frequent hospital re-admission and long-term care. The poor prognosis raises questions as improve cardiopulmonary resuscitation methods and specifically adapt them to newborn babies to improve outcomes. Currently a 3:1 ratio, which equals 3 chest compressions to one rescue breath to resuscitate a newborn baby. This means that chest compressions are stopped after every 3rd compression to give one rescue breath. The investigators believe that this interruption of chest compressions is bad for the newborn baby and that chest compressions should be continued without interruption while rescue breaths are given continuously. The investigators believe that this approach will allow us to reduce death and long-term burdens in newborn babies born without a heartbeat. Furthermore, it is not known if rescue breaths given with 100% oxygen or 21% oxygen (room air) is better for newborn babies. Using continuous chest compressions and rescue breaths without interruptions, this study will compare 21% with 100% oxygen.
Temporary transcutaneous cardiac pacing is a life-saving procedure in patients with unstable bradycardia. The American Heart Association (AHA) guidelines for the management of unstable bradycardia recommend initiating transcutaneous pacing in patients unresponsive to atropine while addressing the primary cause of the bradycardia. The two most commonly described pacer pad application sites are the anterior-posterior (A-P) position (positive pad placed under the left scapula and negative pad placed on the left anterior lower chest wall) and the anterior-lateral (A-L) position (positive pad placed on the right anterior chest wall and negative pad placed on the left lower axilla). Major resuscitation organization (AHA, European, Australian) guidelines and text books of emergency medicine recommendations for pacer pad placement do not address the issue of which set of positions are preferred. There are no published human studies addressing ideal pacer pad placement. This study's objective is to assess if there is a significant difference in the pacing threshold (mA) between these two pacer pad positions. The study hypothesis is that the anterior-posterior position will require a lower current and cause less involuntary muscle contraction. The investigators plan to enroll volunteer human subjects undergoing elective cardioversion in the electrophysiology laboratory for atrial fibrillation/flutter. After successful cardioversion to a sinus rhythm, each subject will be transcutaneously paced to mechanical capture in both pacer pad positions. Optimal placement will be determined by the pad position with the lowest current required for capture. The conclusions of this study will provide evidence for the optimal choice regarding pacer pad placement, which can be used in future resuscitation guidelines.
The aim of this study is to compare the effects of Ivabradine and metoprolol to reduce heart rate prior to coronary CT angiography in patients with advanced heart failure.
The interest of the CAPRI study is to confirm the safety and the efficacy of the ENO/TEO/OTO pacing system when used under 1.5 or 3 Tesla MRI environment and in accordance with the MRI solutions guideline.
Oculocardiac reflex (OCR) is usually happening in pediatric strabismus surgery and observed just when the surgent pulls the ocular muscles. The reflex is one of the trigemino-vagal reflexes, and causes bradycardia, arrhythmia, and even cardiac arrest during eye surgery. Premedication for relaxation with drugs like hydroxyzine dihydrochloride or midazolam before surgery of the pediatric population is often used in Turkey, although it is not recommended in foreign countries. Some recent studies showed that when midazolam and hydroxyzine dihydrochloride used together not only, they lessen agitation before surgery but also they prevent emergence agitation. The primary aim of this prospective observational study is to show the effect of hydroxyzine dihydrochloride on preventing the pediatric patient from Oculocardiac reflex related to strabismus surgery.
Heart rate (HR) is not routinely assessed during newborn resuscitations in low- and lower-middle income countries (LMICs). Many non-breathing newborns classified as fresh stillbirths have a heartbeat and are live born. The effect of a low-cost monitor for measuring HR on the problem of misclassification of stillbirths in LMICs is unknown. Knowledge of HR during newborn resuscitation might also result in timely administration of appropriate interventions, and improvement in outcomes. Helping Babies Breathe (HBB), a resuscitation algorithm developed by the American Academy of Pediatrics (AAP), is widely accepted as the standard of care for newborn resuscitation in low-resource settings. In keeping with the International Liaison Committee on Resuscitation (ILCOR) recommendations that HR be measured during newborn resuscitation, HBB calls for HR assessment after 1 minute of positive-pressure ventilation with good chest movement (or sooner if there is a helper who can palpate/auscultate heart rate). However, given the frequent reality of a single provider attending deliveries in LMICs, as well as the currently available methods for assessing HR (i.e. palpitation or auscultation), assessment of HR is challenging to perform without delaying or stopping the provision of other life-saving interventions such as bag and mask ventilation. The effect of low-cost, continuous HR monitoring to guide resuscitation in these settings is unknown. NeoBeat is a low-cost, battery-operated device designed by Laerdal Global Health for the measurement of newborn HR. The device can be placed rapidly on a newborn by a single provider, and within 5 seconds, displays HR digitally. A preliminary trial of NeoBeat in 349 non-breathing newborns in Tanzania detected a HR in 67% of newborns classified as stillbirths, suggesting up to two thirds of fresh stillbirths may be misclassified in similar settings. This trial will evaluate: 1) the effectiveness of HBB in combination with NeoBeat for vital status detection on reduction of reported stillbirths, and 2) the effectiveness of HR-guided HBB on effective breathing at 3 minutes. The primary hypothesis is that implementation of HBB with measurement of HR using NeoBeat will decrease the reported total stillbirth rate by 15% compared to standard care. The secondary hypothesis is that implementation of HR-guided HBB will increase the proportion of newborns not breathing well at birth who are effectively breathing at 3 minutes by 50% compared to HBB with NeoBeat.
The objective of this study is to assess the accuracy of the Apple Watch 4 Series watch in generating an ECG that is suitable for determination of heart rhythm compared to rhythms monitored via telemetry. Secondary objective is to assess the accuracy of the Apple Watch 4 series watch in identifying atrial fibrillation when it is present.
The objective of this post-market, clinical follow up (PMCF) study, is to confirm the long-term safety of the Tendril STS and Isoflex leads, implanted with the Assurity MRI™ or Endurity MRI™ pacemakers, in patients undergoing a clinically indicated 3T MRI (3 Tesla Magnetic Resonance Imaging) scan.