Clinical Trials Logo

Blood Pressure Determination clinical trials

View clinical trials related to Blood Pressure Determination.

Filter by:
  • None
  • Page 1

NCT ID: NCT05781256 Recruiting - Clinical trials for Arterial Hypertension

Novel BP Monitoring Methods to Study the Association Between Sleep BP Patterns and BP Values in Daily Life

CABER-NET
Start date: June 1, 2022
Phase:
Study type: Observational

Out-of-office blood pressure (BP) measurement by means of ambulatory BP monitoring (ABPM) or home BP monitoring (HBPM) is recommended for the diagnosis and management of hypertension in the latest guidelines. Ambulatory BP values are more strongly associated with target organ damage and cardiovascular (CVD) events than office values. In particular, nocturnal blood pressure level and reduction of BP during the night (dipping) have been recognised as predictors of cardiovascular complications. However, in current clinical practice, these parameters are derived from ABPM. HBPM represents an inexpensive alternative to ABPM, is preferred by patients and provides a more realistic assessment of BP during an individual's daily life. However, until recently, HBPM did not offer the possibility to measure nocturnal BP or dipping. The development and validation of new BP devices, such as the NightView (OMRON Healthcare, HEM9601T-E3) could overcome this limitation, offering the possibility of home night-time BP measurements with minimal sleep disturbance. On the other hand the use of wearable devices such as HeartGuide (OMRON Healthcare, HEM-6411T-MAE) could provide BP values in daily life conditions. Compared with conventional HBP, typically measured in resting conditions at home, values obtained with wearable devices might be closer to daytime ABP values. Combining nocturnal HBP, with daytime BP from wearable device could therefore allow the estimation of dipping status comparable with that provided by ABPM. In order to compare HBP-derived dipping estimate with the gold standard ABPM-derived value, it is aimed to enrol patients with hypertension, assess their blood pressure profile with ABPM and provide them with both NightView and HeartGuide devices for 7 days. Then diurnal and nocturnal BP and dipping derived from standard 24-hour ABPM will be compared and the combination of NightView/HeartGuide in order to understand whether the latter can offer a reliable assessment of 24h BP pattern. For a better phenotypization of nocturnal BP and dipping status the following determinants of nocturnal BP and dipping status will be also investigated: sleep quality, sleep duration, the presence of sleep disorders, salt consumption, catecholamine phenotype. This study will offer the unique opportunity to understand whether such new HBP devices can be offered in alternative to ABPM in the assessment of 24h BP profile in patients with hypertension.

NCT ID: NCT05496322 Recruiting - Clinical trials for Postoperative Complications

Continuous Vs Intermittent Non Invasive Blood Pressure Monitoring in Preventing Post Operative Organ Failure

NiMon
Start date: January 26, 2023
Phase: N/A
Study type: Interventional

Continuous non-invasive arterial pressure monitoring has the potential to decrease the duration of intraoperative hypotension and hypertension compared to conventional intermittent blood pressure monitoring. Chen et al. demonstrated using continuous non-invasive arterial pressure devices for every hour of surgery it is possible to identify an average of 14 minutes of potentially treatable hypotensive and hypertensive time(12). Whether the ability to detect more hypotension events by continuous non-invasive arterial pressure monitoring use can improve patient outcomes, is still an open research question

NCT ID: NCT04789642 Completed - Clinical trials for Blood Pressure Determination

Nurses Education Using Virtual Social Network

Start date: March 15, 2021
Phase: N/A
Study type: Interventional

Regardless of the method used to measure BP, initial and ongoing training of technicians and healthcare providers and the use of validated and calibrated devices are critical for obtaining accurate BP measurements.