Clinical Trials Logo

Clinical Trial Summary

The objective of this trial is to compare the total and regional deposition of aerosol in the lungs and oropharynx of patients with COPD and known poor MDI inhalation technique following inhalation of Berodual delivered via the Respimat inhaler and Berodual delivered via an HFA-metered dose inhaler achieved with their "natural" inhalation technique compared with taught "optimal" technique.


Clinical Trial Description

This is a single dose, randomised, active-controlled, four period, open-label cross-over trial in adult patients with COPD who have demonstrated a poor MDI technique. Berodual (fenoterol hydrobromide 50 μg + ipratropium bromide 20 μg) will be delivered via the Respimat inhaler on two test days and via the MDI on two test days. Test days with no instruction on correct usage will occur prior to the test days with taught technique, so that the patient's own technique will not be influenced by recent instruction. Each device will thus first be used with no instructions on correct device use provided. On these no instruction test days each device will be demonstrated and patients will be allowed time to practice on their own with a placebo device. The second time each device is used full instructions will be provided on the correct usage with patients practicing with placebo either from the Respimat inhaler or from the MDI until they are judged competent. On these two test days the Respimat or MDI inhalers will be fired by the investigator one second after the patient has started to inhale. Thus on Test Days 1 and 2 patients will use their own natural inhalation technique without receiving any instruction on correct usage. On Test Days 3 and 4 patients will use a supervised optimal technique having received instruction on correct usage and with the investigator firing the device. The primary analysis will be carried out using the Sign Test. This is a non-parametric analysis in which no assumptions are made about the shape of the distribution of the responses from the Respimat inhaler and from the MDI under the null hypothesis. Study Hypothesis: The null hypothesis is that poor technique has the same effect on the Respimat and MDI devices. The alternative hypothesis is that poor technique has a different effect on the Respimat inhaler than on the MDI. This means that under the null hypothesis the median of the differences between the Respimat inhaler and MDI pairs is zero i.e. the differences are equally likely to be positive or negative. Under the alternative hypothesis the median of the differences between the Respimat inhaler and MDI pairs is not zero i.e. the frequencies of the positive and negative signs are different. Comparison(s): Baseline comparability will be achieved by the use of a cross-over trial design with every patient receiving all four treatments and by ensuring at each test day that baseline lung function is within 15% of the value obtained at the first test day, pre-dose FEV1 is < 65% of predicted value and patients have abstained from inhaled bronchodilators for at least 4 hours prior to the visit. Treatment sequence will not be fitted as a term in the analysis of variance models. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT00267917
Study type Interventional
Source Boehringer Ingelheim
Contact
Status Completed
Phase Phase 4
Start date January 17, 2006
Completion date February 27, 2006

See also
  Status Clinical Trial Phase
Terminated NCT04410523 - Study of Efficacy and Safety of CSJ117 in Patients With Severe Uncontrolled Asthma Phase 2
Completed NCT04624425 - Additional Effects of Segmental Breathing In Asthma N/A
Active, not recruiting NCT03927820 - A Pharmacist-Led Intervention to Increase Inhaler Access and Reduce Hospital Readmissions (PILLAR) N/A
Completed NCT04617015 - Defining and Treating Depression-related Asthma Early Phase 1
Recruiting NCT03694158 - Investigating Dupilumab's Effect in Asthma by Genotype Phase 4
Terminated NCT04946318 - Study of Safety of CSJ117 in Participants With Moderate to Severe Uncontrolled Asthma Phase 2
Completed NCT04450108 - Vivatmo Pro™ for Fractional Exhaled Nitric Oxide (FeNO) Monitoring in U.S. Asthmatic Patients N/A
Completed NCT03086460 - A Dose Ranging Study With CHF 1531 in Subjects With Asthma (FLASH) Phase 2
Completed NCT01160224 - Oral GW766944 (Oral CCR3 Antagonist) Phase 2
Completed NCT03186209 - Efficacy and Safety Study of Benralizumab in Patients With Uncontrolled Asthma on Medium to High Dose Inhaled Corticosteroid Plus LABA (MIRACLE) Phase 3
Completed NCT02502734 - Effect of Inhaled Fluticasone Furoate on Short-term Growth in Paediatric Subjects With Asthma Phase 3
Completed NCT01715844 - L-Citrulline Supplementation Pilot Study for Overweight Late Onset Asthmatics Phase 1
Terminated NCT04993443 - First-In-Human Study to Evaluate the Safety, Tolerability, Immunogenicity, and Pharmacokinetics of LQ036 Phase 1
Completed NCT02787863 - Clinical and Immunological Efficiency of Bacterial Vaccines at Adult Patients With Bronchopulmonary Pathology Phase 4
Recruiting NCT06033833 - Long-term Safety and Efficacy Evaluation of Subcutaneous Amlitelimab in Adult Participants With Moderate-to-severe Asthma Who Completed Treatment Period of Previous Amlitelimab Asthma Clinical Study Phase 2
Completed NCT03257995 - Pharmacodynamics, Safety, Tolerability, and Pharmacokinetics of Two Orally Inhaled Indacaterol Salts in Adult Subjects With Asthma. Phase 2
Completed NCT02212483 - Clinical Effectiveness and Economical Impact of Medical Indoor Environment Counselors Visiting Homes of Asthma Patients N/A
Recruiting NCT04872309 - MUlti-nuclear MR Imaging Investigation of Respiratory Disease-associated CHanges in Lung Physiology
Withdrawn NCT01468805 - Childhood Asthma Reduction Study N/A
Recruiting NCT05145894 - Differentiation of Asthma/COPD Exacerbation and Stable State Using Automated Lung Sound Analysis With LungPass Device