Clinical Trials Logo

Clinical Trial Summary

Infants are typically fed in a cradled, upright position, however feeding specialists/SLPs often position infants in a side-lying position to promote safe, quality, and neurodevelopmentally protective feeding which is supported by currently available literature. Side-lying position is often recommended by feeding specialists to reduce the risk for aspiration and improve other components of infant swallow function. However, there is no literature directly assessing airway protection during the swallow with the infant in the side-lying versus upright positions. The goal of this study is to conduct an instrumental assessment (Modified Barium Swallow/Videofluoroscopic Swallow Study) in these different positions (upright versus side-lying) to determine if there is a difference in airway compromise. The target population are infants between post-menstrual ages of 38-56 weeks who are referred for a modified barium swallow study.


Clinical Trial Description

Infants are typically fed in a cradled, upright position. With at-risk infants, feeding specialists may adopt a side-lying position to promote safe, quality, and neurodevelopmentally protective feeding. Current literature to support this practice suggests that side-lying position improves physiologic stability during feeding as compared to the traditional cradled or upright position. Side-lying position has several theoretical benefits based on various mechanisms including its similarity to the natural breast-feeding position, reduced hydrostatic pressure of the bottle when it is held horizontally rather than vertically above the infant, increased ease of coordinating suck-swallow-breath due to decreased flow rate, and reduced work of breathing. Another possible reason that side-lying position is beneficial is improved swallow function including decreased incidence of penetration or aspiration, which is the term for food or liquid entering the airway. Aspiration can have devastating effects on infants, particularly premature infants, including respiratory illnesses, need for increased respiratory support, inability to maintain nutrition orally, long term lung damage, and even death. Side-lying position is often recommended by feeding specialists to reduce the risk for aspiration and improve other components of infant swallow function. However, there is no literature directly assessing airway protection during the swallow with the infant in the side-lying versus upright positions. Modified Barium Swallow Studies (MBS) are considered gold standard evaluations of swallowing function and are used to determine the safest bottle-feeding plan for medically-complex infants. MBS performed on infants typically assess multiple parameters, including suck-swallow-breathe coordination and sequencing, pharyngeal residue, timing of swallow initiation, upper esophageal sphincter opening, and presence of penetration (material entering the airway but remaining above the vocal folds) or aspiration (material entering the airway and passing below the vocal folds into the trachea). These studies have traditionally been completed in the upright/cradled position, despite the use of side-lying position clinically. However, this practice is changing, as some clinicians use side-lying during MBS to improve swallow safety and therefore inform feeding recommendations. This study aims to investigate whether there are changes in swallow function of infants fed in side-lying vs upright position during MBS. MBS will be analyzed to assess infant swallow function in side-lying position compared with swallow function in upright position. The following swallow parameters will be analyzed comparatively by position: airway invasion as defined by penetration and aspiration; location of the bolus at the time of swallow initiation, and suck-swallow-breathe coordination. Previous literature suggests that infants fed in side-lying position are better able to control bolus rate and direction of flow than when they are fed in an upright/cradled position; however, these studies use physiologic outcomes and do not actually confirm if this hypothesized benefit is true. Pilot data found that infants were better able to protect their airway during the pharyngeal swallow, as evidenced by reduced rates of penetration or aspiration. Penetration is defined as material entering the airway during feeding but remaining above the vocal folds, whereas aspiration denotes material passing below the vocal folds towards the lungs, as measured by the Penetration-Aspiration Scale. Side-lying position is hypothesized to reduce flow rate of liquid from the oral cavity into the pharynx, allowing the infant increased time to initiate the swallow and protect the airway. Previous literature suggests that infants fed in side-lying position are better able to control bolus rate and direction of flow than when they are fed in an upright/cradled position, leading to swallow initiation with the bolus higher in the pharyngeal cavity. Previous research suggests that infants fed in side-lying position demonstrate improved oxygenation, which may be due to the infants' ease of coordinating breathing and swallowing during feeding. Suck-swallow-breathe coordination may be easier when fed in side-lying position because of the reduced gravitational pull of the liquid into the infant's mouth, and the increased ability to control the flow rate. Pilot data revealed that infants demonstrated fewer swallows per breath when fed in a side-lying position, which may indicate a more coordinated swallow-respiration sequence. Pilot data revealed that airway invasion (penetration and aspiration) was statistically significantly reduced, location of the bolus at time of swallow initiation was statistically significantly higher, and number of swallows per breaths were statistically significantly lower when infants were fed in a side-lying position compared to an upright/cradled position. That pilot investigation validates the need for additional research to further define the mechanisms related to this improvement, and to determine how diagnosis and medical stability moderate these findings. If findings support that side-lying position decreases aspiration risk, it updates the standard of care for feeding, especially for at-risk infants who are not able to undergo instrumental swallow testing. Side-lying is a no-cost strategy with the potential to enhance infant and caregiver quality of life through safe and developmentally appropriate nutritional intake. Conversely, if results indicate side-lying increases swallowing risk in certain populations, this is also significant and directs the standard of care for hospitals that routinely advise side-lying in the absence of instrumental swallow testing. This work informs best practices for clinical practitioners (e.g., SLP, RN, MD, etc.) and infant caregivers (i.e., parents) to minimize the risk of aspiration and its possible health consequences. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05874102
Study type Interventional
Source Connecticut Children's Medical Center
Contact
Status Enrolling by invitation
Phase N/A
Start date January 13, 2023
Completion date December 2024

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04083677 - Routine Point of Care Ultrasound (POCUS) Assessment of Antral Gastric Contents in Traumatic Surgical Patients for Prevention of Aspiration Pneumonitis
Terminated NCT05101668 - Safety and Efficacy of Intracranial Thrombus Aspiration Catheter in the Treatment of Acute Large-vessel Occlusive Stroke N/A
Completed NCT02588495 - Accuracy of Gastric Ultrasound to Diagnose a "Full Stomach". A Bayesian Framework N/A
Completed NCT02576756 - Retrospective Study in Patients Who Have Had a Difficult Intubation. N/A
Completed NCT01777672 - Effect of Afferent Oropharyngeal Pharmacological and Electrical Stimulation on Swallow Response and on Activation of Human Cortex in Stroke Patients With Oropharyngeal Dysphagia Phase 2
Completed NCT05033041 - Gastric Volumes by US in Term Parturients Undergoing CS With and Without Metoclopramide Phase 4
Recruiting NCT05079620 - Early Antibiotics After Aspiration in ICU Patients Phase 4
Completed NCT01011803 - Correlation of Phonation With Deglutition and Aspiration Risk in the ICU Patients - an Exploratory Study N/A
Recruiting NCT06137976 - Surgeon Perception of Gastric Decompression at Time of Gynecologic Laparoscopy N/A
Completed NCT04645043 - Ultrasound Guided Esophageal Pressure N/A
Completed NCT01807884 - Comparison of Two Strategies of Oropharyngeal and Tracheal Suctioning in Mechanically Ventilated Patients N/A
Completed NCT03573609 - Evaluation of the Effectiveness and Safety of Supratube Device N/A
Completed NCT03555604 - Evaluation of the Effect of Body Mass Index on Gastric Volume With Ultrasound in Term Pregnant Women
Enrolling by invitation NCT04411290 - Malignancy Predictors, Bethesda and TI-RADS Scores Correlated With Final Histopathology in Thyroid Diseases
Completed NCT05734937 - Ultrasound Evaluation of Gastric Volume in Pediatric Patients Undergoing Adenotonsillectomy Surgery N/A
Recruiting NCT05330351 - Gastric Ultrasound in Pediatric Trauma Patients
Terminated NCT02437513 - NewBreez for Airway Protection in Head and Neck Cancer Patients With Chronic Aspiration N/A
Completed NCT04786691 - How do You Take Your Coffee Before Anesthesia N/A
Completed NCT05434442 - Caregivers Tracheal Aspiration Training N/A
Completed NCT03305757 - Seroma Reduction After Mastectomy Phase 4