Clinical Trials Logo

Clinical Trial Summary

Background: Artificial Intelligence (AI) in cardiac imaging has previously been shown to provide highly reproducible and accurate results, outperforming clinical experts. Cardiac magnetic resonance (CMR) imaging represents the gold standard for assessment of myocardial structure and function. However, measurements of more sensitive markers of early left (LV) and right ventricular (RV) function, such as global longitudinal shortening (GLS), mitral annular plane systolic excursion (MAPSE), and tricuspid annular plane systolic excursion (TAPSE), are frequently not performed due to the lack of automated analysis. Objectives: The investigators aim to evaluate whether AI-based measurements of ventricular structure and function convey important prognostic information in patients with severe aortic stenosis (AS) beyond LV and RV ejection fraction (EF) and represent early markers of adverse cardiac remodeling. Materials & Methods: This large-scale international, multi-center, observational study will recruit ~1500 patients with severe AS scheduled for aortic valve replacement (AVR). Patients are invited to undergo CMR imaging prior to AVR and at 12-months post-AVR. An AI-based algorithm, developed in the UK, will be used for fully automated assessment of parameters of cardiac structure (end-diastolic volume, end-systolic volume, LV mass, maximum wall thickness) and function (EF, GLS, MAPSE, TAPSE). Application of the AI-model allows to capture these parameters for large patient cohorts within seconds (as opposed to the current practice of time-consuming manual post-processing). Association of AI-based CMR parameters with clinical outcomes post-AVR will be analyzed. The composite of all-cause mortality and heart failure hospitalization will serve as the primary endpoint. Trajectories of AI-based parameters from pre- to post-AVR will be assessed as a secondary endpoint. Future Outlook: In severe AS, a novel AI-based algorithm allows immediate and precise measurements of ventricular structure and function on CMR imaging. Our goal is to identify early markers of cardiac dysfunction indicating adverse prognosis post-AVR. This has guideline-forming potential as the optimal timepoint for AVR in patients with AS is currently a matter of debate.


Clinical Trial Description

Artificial Intelligence (AI) and Machine Learning are reshaping our daily clinical practice, which has the potential to be more efficient, precise, and personalized. Adopting these technologies in cardiac imaging does not only affect decision making by improved accuracy and risk stratification but also significantly reduces scan times and post-imaging workup. Current guidelines acknowledge cardiac magnetic resonance (CMR) imaging as gold standard for assessment of myocardial structure and function. Although of fundamental importance in various cardiac diseases, measurements of size, mass, and ejection fraction (EF) are flawed by the inherent variability and subjectivity of human analysis. Recent developments in deep learning using convolutional neural networks (CNNs) allow for automated segmentation of the ventricular blood pool and myocardium using pre-existing CMR datasets. Importantly, these tools are integrated into CMR scanners generating real-time measurements without the need of time-consuming image post-processing. AI-based models have previously shown superior precision in ventricular contouring, volumetry, and maximum wall thickness measurements, outperforming clinical experts. In patients with aortic stenosis (AS), changes in EF more often occur late in the disease process. Longitudinal shortening represents an earlier and more sensitive marker of left ventricular (LV) dysfunction. However, these measurements remain subjective, time-consuming, and are therefore not routinely performed due to the lack of automated analysis. Recently, AI-measured global longitudinal shortening (GLS) and mitral annular plane systolic excursion (MAPSE) have been demonstrated to provide more reproducible and accurate results, when compared to human experts. The investigators hypothesize that AI-based GLS and MAPSE could convey important prognostic information beyond LVEF in severe AS and represent early markers of adverse cardiac remodeling. Furthermore, the investigators could previously demonstrate that right ventricular (RV) dysfunction on CMR, rather than conventional parameters assessed by echocardiography, was independently associated with outcome in individuals with AS undergoing transcatheter aortic valve implantation. The investigators aim to extend on our findings and investigate whether AI-based RV GLS and tricuspid annular plane systolic excursion (TAPSE) represent early markers of RV dysfunction indicating adverse prognosis. Finally, the assessment of reverse cardiac remodeling by CMR requires high precision (=reproducibility). AI has been proven to outperform humans in both precision and accuracy, and therefore has great potential for the comprehensive evaluation of longitudinal structural changes in AS following valve replacement. The investigators aim to analyze reverse cardiac remodeling in patients with AS using novel AI technology. Aims With significant previous contributions in cardiac imaging and valvular heart disease being made in the past, the investigators aim to expand the knowledge in this field by exploring the following: - Association of AI-measured LV and RV structural and functional markers on CMR in patients with severe AS with clinical outcomes following aortic valve replacement (AVR). - Reverse cardiac remodeling at baseline to 12-months after AVR as determined by AI-based CMR methods. - The ultimate goal is to provide automated, precise, and time-saving algorithms to identify patients at risk undergoing AVR. Methods This is a large-scale international, multi-center, multi-cohort, observational study. Patients with severe degenerative AS scheduled for valvular treatment discussion in an interdisciplinary Heart Team will be invited to participate. Enrollment will be performed prospectively at seven university-affiliated tertiary care centers in Continental Europe, the UK, and Asia. Baseline evaluation consists of medical history, physical examination, routine blood tests, electrocardiogram, echocardiography, and CMR imaging. Patients will be prospectively followed up by an ambulatory visit at 12 months. In addition, CMR will be repeated at 1 year. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06128876
Study type Observational
Source Medical University of Vienna
Contact
Status Not yet recruiting
Phase
Start date March 1, 2024
Completion date February 28, 2026

See also
  Status Clinical Trial Phase
Recruiting NCT04310046 - Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial N/A
Recruiting NCT06008080 - Post-Market Clinical Follow Up Study With Navitor Valve
Recruiting NCT06055751 - Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
Active, not recruiting NCT04815785 - Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis N/A
Terminated NCT02202434 - Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement N/A
Recruiting NCT03029026 - The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
Active, not recruiting NCT02903420 - A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan) N/A
Completed NCT02629328 - CardioCel Tri-leaflet Repair Study N/A
Completed NCT02306226 - Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
Completed NCT01676727 - ADVANCE Direct Aortic Study
Withdrawn NCT01648309 - Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation N/A
Completed NCT01422044 - Risk Prediction in Aortic Stenosis N/A
Withdrawn NCT00774657 - Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography N/A
Terminated NCT00535899 - Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) N/A
Terminated NCT05070130 - OpSens PRIME CLASS
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT04157920 - Impact of Predilatation Between Self-expanding Valves N/A
Enrolling by invitation NCT06212050 - Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
Recruiting NCT05893082 - Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR N/A
Completed NCT03250806 - Early Detection of Aortic Stenosis in the Community During Flu Vaccination