Clinical Trials Logo

Clinical Trial Summary

Since its first clinical introduction by Alan Cribier in 2002, transcatheter aortic valve implantation has become the treatment of choice for severe aortic stenosis in high-risk and elderly patients. In such a population, cardiac surgery after TAVI is seldom performed (<1%), and only in cases of life-threatening complications such as device embolization, heart rupture, aortic dissection, endocarditis, etc. - State-of-the-art Nowadays, patients submitted to TAVI are getting younger, with lower surgical risk and longer life-expectancy, and their number is continuously increasing . As a consequence, the number of patients treated with TAVI who will require subsequent cardiac surgery will also expand, both acutely (due to the above-mentioned complications) and during follow-up (due to late endocarditis, valve degeneration and other non-aortic indications). - Previous informations Despite cardiac surgery after TAVI has been already performed several times across the world without documented issues in regard to aortic cross-clamp and aortotomy, it has been long debated whether the presence of TAVI devices with a tall stent frame in the ascending aorta may theoretically jeopardize the ability of surgeons to clamp and open the aorta. No specific data is yet available in regard to the existence and the incidence of such issue. - Ethical issues Not present. Aim of the study The aim of this study was to assess the anatomical feasibility of surgical aortic cross-clamp and aortotomy after TAVI based on post-TAVI computed tomographies (CT). Study design This study enrolled patients who underwent TAVI in three high-volume centers (San Raffaele University Hospital in Milan - Italy, Rigshospitalet Univeristy Hospital in Copenhagen - Denmark, Semmelweiss University in Budapest - Hungary) between October 2008 and May 2017. 117 CT acquired after TAVI procedures that were cardiac-gated and included the aortic arch into the field of view were retrospectively reviewed. 11 patients of San Raffaele Hospital will be involved. Reasons for post-TAVI acquisition were: participation into a clinical study with a previous Ethical Committee approval (91.4% n = 107); residual aortic regurgitation assessment for Valve-in-Valve evaluation (6.0% n = 7); TAVI complication assessment (ventricular septum defect 1.7% n = 2, left ventricular outflow tract obstruction 0.9% n = 1). Median time of CT acquisition after TAVI was 451 [290-780] days. As per study design, only TAVI devices with a long stent were assessed: CoreValve (Medtronic Inc., MN, USA) n = 82 (size 26 n = 23; size 29 n = 48; size 31 n = 11); CoreValve Evolut R (Medtronic Inc., MN, USA) n = 19 (size 23 n = 1; size 26 n = 7; size 29 n = 10; size 34 n = 1); Portico (Abbott, IL; USA) n = 16 (size 25 n = 9; size 27 n = 4; size 29 n = 3). Acurate Neo device (Boston Scientific, MA, USA, former Symetis) presents three stabilization arches in the ascending aorta which differ this prosthesis from the circular tubular stent of other self-expandable valves. To limit the introduction of possible confounding factors in the analysis, the investigators decided on purpose not to include the Acurate in the present study. Indication for TAVI respects international guidelines (EACTS 2017 Guidelines for Treatment of Valvular Heart Disease). A transthoracic examination is performed before the procedure at hospital admission. The in-hospital pathway pf examination is equal to every other patient treated in the participating centers.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT05721820
Study type Observational
Source Ospedale San Raffaele
Contact
Status Completed
Phase
Start date October 5, 2019
Completion date October 16, 2019

See also
  Status Clinical Trial Phase
Recruiting NCT04310046 - Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial N/A
Recruiting NCT06008080 - Post-Market Clinical Follow Up Study With Navitor Valve
Recruiting NCT06055751 - Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
Active, not recruiting NCT04815785 - Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis N/A
Terminated NCT02202434 - Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement N/A
Recruiting NCT03029026 - The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
Active, not recruiting NCT02903420 - A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan) N/A
Completed NCT02629328 - CardioCel Tri-leaflet Repair Study N/A
Completed NCT02306226 - Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
Withdrawn NCT01648309 - Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation N/A
Completed NCT01676727 - ADVANCE Direct Aortic Study
Completed NCT01422044 - Risk Prediction in Aortic Stenosis N/A
Withdrawn NCT00774657 - Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography N/A
Terminated NCT00535899 - Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) N/A
Terminated NCT05070130 - OpSens PRIME CLASS
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT04157920 - Impact of Predilatation Between Self-expanding Valves N/A
Enrolling by invitation NCT06212050 - Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
Recruiting NCT05893082 - Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR N/A
Completed NCT03250806 - Early Detection of Aortic Stenosis in the Community During Flu Vaccination