Clinical Trials Logo

Clinical Trial Summary

This is a prospective single center Cardiology department observational study. The study aim is to better understand the predictors of high grade conduction abnormalities associated with TAVR such that a more robust evidence-based and universal strategy to manage cardiac conduction disturbances in these patients, which has been elusive, can be developed.


Clinical Trial Description

TAVR is a very commonly performed procedure throughout the world; it has become standard of care as the treatment for aortic stenosis and is performed in hundreds of thousands of patients annually. TAVR affords patients therapies that prolong life and improve quality of life; furthermore, these therapies afford certain patients who are not candidates for surgical options hope for the future. Adults undergoing TAVR may suffer the complication of requiring a pacemaker after the procedure, in up to 30% of cases. Interventionalists still don't understand how to best predict this complication; in fact some patients that ultimately need a pacemaker don't get one after the procedure and some that get a pacemaker are found to ultimately not have really needed it. A better understanding of which patients do and do not need pacemakers will help prevent complications of high grade block in those without pacemaker (death, syncope and trauma) and also the complications of unnecessary pacemaker implantation (infection, tricuspid regurgitation). Primary hypothesis: EP studies (EPS), when performed before and after TAVR adds independent incremental value, above and beyond other parameters, for the prediction of high-grade heart block after TAVR. The goal is to understand conduction disease changes before and after TAVR, coupled with other patient and procedural factors that can help create a management algorithm for conduction disease after TAVR. Primary endpoint: to find correlation coefficients between a) absolute and delta values of various EPS findings, and b) clinical endpoint of high-grade conduction disease as diagnosed clinically, by ECG, by event monitor, or by interrogation of permanent pacemaker implanted after TAVR. Methods: Patients will receive EPS immediately before and after TAVR (while on the catheterization lab table for TAVR procedure) and then again the next day; this information will help determine whether the patient gets a pacemaker, a 30-day event monitor, or neither. The investigators will study which parameters obtained during the EPS, in addition to other known/suspected predictors of conduction disease after TAVR, best correlate with serious problems with the heart's electrical conduction system as determined by clinical follow-up. Anticipated findings: that the EPS findings add incremental and independent value in predicting which patients will develop high grade conduction disease. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04489095
Study type Interventional
Source Henry Ford Health System
Contact
Status Completed
Phase N/A
Start date July 16, 2020
Completion date August 1, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT04310046 - Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial N/A
Recruiting NCT06008080 - Post-Market Clinical Follow Up Study With Navitor Valve
Recruiting NCT06055751 - Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
Active, not recruiting NCT04815785 - Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis N/A
Terminated NCT02202434 - Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement N/A
Recruiting NCT03029026 - The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
Active, not recruiting NCT02903420 - A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan) N/A
Completed NCT02629328 - CardioCel Tri-leaflet Repair Study N/A
Completed NCT02306226 - Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
Withdrawn NCT01648309 - Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation N/A
Completed NCT01676727 - ADVANCE Direct Aortic Study
Completed NCT01422044 - Risk Prediction in Aortic Stenosis N/A
Withdrawn NCT00774657 - Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography N/A
Terminated NCT00535899 - Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) N/A
Terminated NCT05070130 - OpSens PRIME CLASS
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT04157920 - Impact of Predilatation Between Self-expanding Valves N/A
Enrolling by invitation NCT06212050 - Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
Recruiting NCT05893082 - Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR N/A
Completed NCT03250806 - Early Detection of Aortic Stenosis in the Community During Flu Vaccination