Clinical Trials Logo

Clinical Trial Summary

Background: Transcatheter aortic valve replacement (TAVR) is a non-surgical alternative to standard surgical aortic valve replacement. Not all patients are eligible for TAVR using standard access through the artery in the groin, because the artery is too small or too diseased. In this study, TAVR is performed using a new technique called transcaval access. The catheter is placed in the artery deep in the body by crossing through the wall of a deep vein. The connection between that vein and the aorta is closed with a new metallic device they are testing. This is called a transcaval closure device (TCD). Objective: To test the safety and early feasibility of closure of transcaval aortic access sites using the TCD after TAVR. Eligibility: Adults ages 21 and older undergoing TAVR for whom the procedure cannot be performed safely by the standard artery approach Design: Participants will be assessed by heart experts including cardiologists and surgeons. Participants will have TAVR by the transcaval approach. A small catheter will be passed between the largest vein in the body and the nearby largest artery (aorta), inside the abdomen. Through this catheter, the TAVR will be implanted in the usual way. After, doctors will implant the TCD by catheter to close the hole made in the aorta. Participants will be X-rayed. A dye will be injected to view the TCD device. Participants will get standard TAVR care afterwards. They will have physical exams, blood tests, and scans. Participants will have a follow-up scan within 1 month and after 12 months. Participants will have follow-up visits and phone calls 6 and 12 months after the procedure.


Clinical Trial Description

Transcaval access to the abdominal aorta from the neighboring inferior vena cava (IVC) enables transcatheter aortic valve replacement (TAVR) in patients not eligible for femoral artery access. Currently the procedure is performed using devices, off-label, designed and marketed to close holes inside the heart and great vessels, manufactured by Abbott St Jude (Amplatzer Duct Occluder and Amplatzer Muscular VSD Occluder). Because these Amplatzer occluders are not designed to close transcaval access sites, they may not completely prevent bleeding. This is an early feasibility study (EFS) evaluation of a purpose-built closure device for transcaval access. The device, the Transcaval closure device (TCD) will be evaluated for safety and performance to close transcaval access sites in patients ineligible for femoral artery access for TAVR. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03432494
Study type Interventional
Source National Institutes of Health Clinical Center (CC)
Contact
Status Terminated
Phase N/A
Start date February 7, 2018
Completion date April 29, 2019

See also
  Status Clinical Trial Phase
Recruiting NCT04310046 - Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial N/A
Recruiting NCT06008080 - Post-Market Clinical Follow Up Study With Navitor Valve
Recruiting NCT06055751 - Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
Active, not recruiting NCT04815785 - Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis N/A
Terminated NCT02202434 - Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement N/A
Recruiting NCT03029026 - The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
Active, not recruiting NCT02903420 - A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan) N/A
Completed NCT02629328 - CardioCel Tri-leaflet Repair Study N/A
Completed NCT02306226 - Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
Withdrawn NCT01648309 - Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation N/A
Completed NCT01676727 - ADVANCE Direct Aortic Study
Completed NCT01422044 - Risk Prediction in Aortic Stenosis N/A
Withdrawn NCT00774657 - Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography N/A
Terminated NCT00535899 - Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) N/A
Terminated NCT05070130 - OpSens PRIME CLASS
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT04157920 - Impact of Predilatation Between Self-expanding Valves N/A
Enrolling by invitation NCT06212050 - Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
Recruiting NCT05893082 - Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR N/A
Completed NCT03250806 - Early Detection of Aortic Stenosis in the Community During Flu Vaccination