Clinical Trials Logo

Clinical Trial Summary

Currently, aortic stenosis (AS) is considered a "surgical disease" with no medical therapy available to improve any clinical outcomes, including symptoms, time to surgery, or long-term survival. Thus far, randomized studies involving statins have not been promising with respect to slowing progressive valve stenosis. Beyond the valve, two common consequences of aortic stenosis are hypertrophic remodeling of the left ventricle (LV) and pulmonary venous hypertension; each of these has been associated with worse heart failure symptoms, increased operative mortality, and worse long-term outcomes. Whether altering LV structural abnormalities, improving LV function, and/or reducing pulmonary artery pressures with medical therapy would improve clinical outcomes in patients with AS has not been tested. Animal models of pressure overload have demonstrated that PDE5 inhibition influences NO-cGMP signaling in the LV and favorably impacts LV structure and function, but this has not been tested in humans with AS. Studies in humans with left-sided heart failure and pulmonary venous hypertension have shown that PDE5 inhibition improves functional capacity and quality of life, but patients with AS were not included in those studies. The investigators hypothesize that PDE5 inhibition with tadalafil will upregulate NO-cGMP signaling, reduce oxidative stress, and have a favorable impact on LV structure and function as well as pulmonary artery pressures and quality of life. In this pilot study, the investigators anticipate that short-term administration of tadalafil to patients with AS will be safe and well-tolerated.


Clinical Trial Description

Patients with severe symptomatic AS who will undergo elective aortic valve replacement will be eligible for this randomized, double-blind, placebo-controlled, pilot study. Prior to randomization, subjects will have testing including: 6 minute walk, quality of life questionnaire, blood draw, and an echocardiogram. If an initial monitored dose of tadalafil is tolerated, participants will be randomized 2:1 to tadalafil vs. placebo. After 4 weeks on drug or placebo, subjects will have the same baseline testing repeated. At the time of aortic valve replacement surgery, the aortic valve and a small piece of LV myocardium will be taken for several analyses. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01272388
Study type Interventional
Source Washington University School of Medicine
Contact
Status Terminated
Phase Phase 4
Start date January 2011
Completion date April 2012

See also
  Status Clinical Trial Phase
Recruiting NCT04310046 - Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial N/A
Recruiting NCT06008080 - Post-Market Clinical Follow Up Study With Navitor Valve
Recruiting NCT06055751 - Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
Active, not recruiting NCT04815785 - Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis N/A
Terminated NCT02202434 - Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement N/A
Recruiting NCT03029026 - The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
Active, not recruiting NCT02903420 - A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan) N/A
Completed NCT02629328 - CardioCel Tri-leaflet Repair Study N/A
Completed NCT02306226 - Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
Completed NCT01676727 - ADVANCE Direct Aortic Study
Withdrawn NCT01648309 - Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation N/A
Completed NCT01422044 - Risk Prediction in Aortic Stenosis N/A
Withdrawn NCT00774657 - Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography N/A
Terminated NCT00535899 - Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) N/A
Terminated NCT05070130 - OpSens PRIME CLASS
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT04157920 - Impact of Predilatation Between Self-expanding Valves N/A
Enrolling by invitation NCT06212050 - Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
Recruiting NCT05893082 - Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR N/A
Completed NCT03250806 - Early Detection of Aortic Stenosis in the Community During Flu Vaccination