Clinical Trials Logo

Clinical Trial Summary

Patient Specific Instrumentation (PSI) is thought to quicken joint arthroplasty surgery by shortening the operation time and improving alignment. Studies about the learning curve of PSI for total ankle replacement (TAR) are lacking because it was only introduced in 2014. The investigators believe that PSI could give a beginning ankle surgeon, or surgeons new to TAR, an advantage since PSI facilitates the complex TAR procedure. As such, the availability of TAR in Dutch patients with end-stage ankle osteoarthritis could be extended. To estimate this potential of PSI for TAR, the investigators aim (1) to compare the alignment accuracy of TAR performed using PSI between a beginning and an experienced orthopedic surgeon, and (2) to determine the learning curve of TAR performed using PSI for a beginning foot and ankle specialist by comparing the operative time, complications, and patient-reported outcomes with those of an experienced specialist.


Clinical Trial Description

Total ankle replacement (TAR) as treatment of end-stage osteoarthritis of the ankle is gaining popularity past few years, resulting in a growing number of TAR placed each year. This is an important progression because osteoarthritis of the ankle is suggested to be as disabling as chronic kidney injury or heart failure. Though TAR is proposed to be superior to ankle arthrodesis (AA) with regard to patient quality of life, it is not commonly available in the Netherlands. Merely 149 TARs were registered nationally in 2020. Patient Specific Instrumentation (PSI) is thought to quicken the process by shortening the operation time and improving alignment. Though the literature is submerged in studies about the learning curves of PSI and TAR, research about the learning curve of PSI TAR is lacking because it was only introduced in 2014. Preliminary results showed that the use of PSI resulted in lower average pain scores and earlier recovery compared to TAR using standard instrumentation. Yet the absolute advantage of PSI was not established because of limited research. Furthermore, all previous studies were performed by skilled surgeons to eliminate the bias of inexperience. The investigators believe that PSI could give a beginning ankle surgeon, or surgeon new to TAR, an advantage since PSI facilitates the complex TAR procedure. As such, the availability of TAR in Dutch patients with end-stage ankle osteoarthritis could be extended. To estimate this potential of PSI for TAR, the investigators aim (1) to compare the alignment accuracy of TAR performed using PSI between a beginning and an experienced orthopedic surgeon, and (2) to determine the learning curve of TAR performed using PSI for a beginning foot and ankle specialist by comparing the operative time, complications, and patient-reported outcomes with those of an experienced specialist. It is hypothesized that the alignment of PSI TAR performed by a beginning orthopedic surgeon does not significantly differ from one performed by an experienced surgeon. Furthermore, it is hypothesized that the operative time, complications, and patient-reported outcomes do not significantly differ between a beginning and an experienced orthopedic surgeon. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05729958
Study type Observational
Source Centre for Orthopaedic Research Alkmaar
Contact
Status Not yet recruiting
Phase
Start date April 2024
Completion date December 2025

See also
  Status Clinical Trial Phase
Completed NCT02508233 - Cross-cultural Adaptation and Validation of the Ankle Osteoarthritis Scale (AOS) for Use in French-speaking Populations N/A
Completed NCT01504438 - Prospective Randomized Evaluation of a Two and Three Piece Total Ankle Replacement N/A
Active, not recruiting NCT03440008 - Improving the Detection, Classification and Treatment of Misaligned Arthritic Ankles
Active, not recruiting NCT06404801 - Development of Stance Control Orthotic Knee Joint For Improvement of KAFO Users
Active, not recruiting NCT04405297 - A Disease-based Treatment Study for Diagnosed Osteoarthritis Utilizing Adipose-derived Regenerative Cells
Completed NCT01760577 - Effects of Intraarticular Botulinum Toxin A in Ankle Osteoarthritis N/A
Active, not recruiting NCT04998162 - Injections of SVF in Ankle Osteoarthritis N/A
Completed NCT03356951 - Gait Analysis Following Total Ankle Replacement and Subtalar Fusion N/A
Completed NCT02489188 - Gait Asymmetry Assessed Using Portable Gait Analysis System
Completed NCT01986244 - Total Ankle Replacement for Ankle Arthritis
Withdrawn NCT05562154 - Lateral Approach Versus Anterior Approach in Total Ankle Replacement N/A
Active, not recruiting NCT03567187 - Cryoneurolysis for Improvements in Pain, ADL and QOL in Patients With Ankle Osteoarthritis N/A
Completed NCT05868759 - Assessment of Preoperative and Postoperative Ankle Kinematics N/A
Recruiting NCT06193057 - Comparison of Customized and Standard Total Ankle Prostheses N/A
Recruiting NCT06028763 - Development of Biomedical Technology for the Treatment of Ankle Cartilage Using Injectable Biocomposite Hydrogel N/A
Not yet recruiting NCT03573245 - Tranexamic Acid in Major Orthopedic Surgery: Comparison of 3 Dosage Regimen
Completed NCT04022928 - A Single Intraarticular Injection of Platelet-Rich Plasma on Pain and Physical Function in Patients With Ankle OA N/A
Active, not recruiting NCT02629731 - Orthotic Dose Response Study N/A
Recruiting NCT03157141 - Ankle Osteoarthritis N/A
Active, not recruiting NCT03524729 - Do Rocker Bottom Shoes and Ankle-Foot Orthoses Reduce Pain and Improve Mobility for Ankle Osteoarthritis Patients N/A