NCT ID: NCT05943236 Recruiting - X-ray Clinical Trials

Assessment of the Ankle Joint Axis Using a Long Ankle View Radiograph

LAVIEW
Start date: June 1, 2023
Phase:
Study type: Observational

The study is a reliability (reproducibility) study on a single measurement procedure. Reliability (reproducibility) will be assessed by repeating the whole measurement procedure twice. The measurement procedure studied is the generation of a long ankle view image based on a radiographic assessment followed by a manual assessment of the medial-distal tibial angle.

NCT ID: NCT03286270 Completed - Bone Fracture Clinical Trials

A mRUS Validation Study for Nail-treated Fractures of Long Bones and a TUS Exploratory Study for Nail and Plate-treated Fractures of Long Bones

mRUSTUS
Start date: September 1, 2017
Phase:
Study type: Observational

Early intervention attempts to shorten protracted delayed union (DU) or prevent non-union (NU) fractures are hampered by lack of validated quantitative assessment tools for bone fracture healing during normal and delayed healing processes. In actual practice, sequential X-rays usually follow a pre-determined time interval in patients with fractures.They constitute the best available state of the art used by surgeons to assess the fracture healing course. In an attempt to improve between raters reliability of radiographic assessment of healing, studies have explored a novel radiographic assessment for tibial shaft fractures, the Radiographic Union Scale for Tibial Fractures (RUST). The RUST assesses the presence of bridging callus and a fracture line on each of four cortices (seen on anterior-posterior and lateral views). This callus based scoring system has been since extended to other bones than the tibia in a retrospective case series. It has been renamed modified radiological union score (mRUS) and has shown potential value in bone healing measurement. Based on an initial retrospective study in nail-treated fractures, the first objective of the present investigation is to prospectively validate mRUS as a tool to identify patients at increased risk of DU and NU within the first 75-110 days after fracture occurrence. This prospective validation will be performed on a retrospective cohort of patients having sustained long bone fractures, including both upper and lower extremities. A further objective of the present investigation is to apply the scoring system to tomographic imaging in case of nail/plate treated fractures, deriving a tomographic union score (TUS) and first assess its potential value in bone healing for fractures treated by nails/plates.

NCT ID: NCT00059137 Completed - X-Ray Clinical Trials

Breathing Cycle Biofeedback During Computed Tomography Procedures

Start date: April 2003
Phase: N/A
Study type: Observational

This study will evaluate the effectiveness of a flexible belt device in guiding patient breathing during computed tomography (CT)-guided needle biopsy. When patients undergo CT scanning to help guide the physician during a tissue biopsy, they are usually asked to hold their breath while the scan is taken of certain parts of the body. When the first scan is completed, the patients are allowed to breathe, and are then asked to hold their breath again while the needle is advanced towards the tissue to be biopsied. Since body organs and tissues move with breathing, this study will try to stop the patient's breathing at the same place in the breathing cycle to ensure that the biopsy target stays still and in the same place. This study will see if the flexible belt, used with a computer screen that charts the patient's breathing, will improve the patient's ability to stop breathing at the same place in the breathing cycle before and during the biopsy. Patients 18 years of age and older who have a lesion requiring a needle biopsy in the chest or abdominal area may be eligible for this study. The biopsy procedure must require CT scan guidance. Participants will undergo the following procedures: - Breathing exercise: A flexible, loose-fitting belt is placed around the patient's abdomen and the patient is asked to stop breathing in the following ways: 1) take a deep breath in and hold; 2) breathe deeply out and hold; and 3) breathe regularly and hold. - Needle biopsy: The patient is positioned in a CT scanner and is asked to hold his or her breath while an initial scan is taken. Then the patient is taken out of the scanner and the place the needle entry site for the biopsy is marked on the skin. A local anesthetic is applied to the site and the patient is asked to hold his or her breath the same way as before. During this breath hold, the patient may or may not be shown a computer screen displaying a graph of the patient's breathing and the point in the cycle of the previous breath hold. The biopsy is then performed with CT guidance. While the CT pictures are being taken, the patient is again asked to breathe and hold his or her breath as before. When the biopsy is completed, the belt device is removed.