View clinical trials related to Wrist Fractures.
Filter by:Distal Radius End Fracture (DRC) is one of the most common fractures among all extremity fractures and wrist fractures . Pain, edema and functional loss are common findings in patients, and the physiotherapy program should be well planned from an early time. However, although there are different physiotherapy and rehabilitation applications in the treatment of DRC, there is not enough information about the effectiveness of the applications when the evidence-based studies are examined. The aim of this study is to investigate the effect of motor imagery added to conventional treatment versus conventional treatment with telerehabilitation in patients with distal radius end fracture. Motor imagery is defined as the mental presentation of voluntary movement without body movement. It is an application that does not require cost and it is a training that can be easily applied in rehabilitation programs. Telerehabilitation is important in the management of patients in the acute phase of the disease, as well as in the remote management of individuals with chronic health problems. Cases who applied to Istanbul University-Cerrahpaşa Medical Faculty Orthopedics and Traumatology Clinic and were referred to Istanbul University-Cerrahpaşa Physiotherapy and Rehabilitation Department will be included in the study. Few studies have examined the effects of motor imagery on pain, kinesiophobia, and functionality in musculoskeletal injuries. Studies on the effects of motor imagery on different patient groups are needed. Therefore, in our study, the effect of motor imagery training applied with the telerehabilitation method on pain, kinesiophobia and functionality in patients with distal radius end fracture will be examined. Sociodemographic data form of all subjects who volunteered to participate in the study; Age, gender, height, weight, pain, dominant extremity, and the type of fracture will be questioned. In addition, pain intensity is measured with a visual analog scale, normal joint movement measurement (wrist flexion, extension, ulnar and radial deviation, and forearm supination and pronation) with goniometer, hand grip strength with "Hydraulic hand dynamometer" , finger grip strength "Hydraulic Finger Dynamometer", kinesiophobia Tampa Kinesiophobia Scale, functionality "Arm, Shoulder and Hand Injury Questionnaire in Turkish (Disabilities of Arm, Shoulder and Hand-Turkish - DASH-T and The Patient-Based Wrist Assessment Questionnaire (HBEBD), with the fine dexterity Moberg Pick Up test, the motor imagery ability with the Recognize™ phone app and the Kinesthetic and Visual Imagery Questionnaire, quality of life will be evaluated with SF-12. After the initial evaluation, the treatment program was started. Advances in the treatment method specific to the groups they belong to are explained in detail below. Treatment: After the distal radius end fracture, after 6 weeks of plaster application, after the first evaluation to be made in the clinic after the plaster was removed, in the next session, after patient education, conventional treatment was applied to the cases in Group 1, 3 days a week as stated below. Group 2: Conservative Treatment + Motor Imagery Program Patients in this group will have motor imagery in addition to conservative treatment. The patients in this group will first be given a motor imagery introductory session. According to the results of the observation and evaluation made by the physiotherapist before the treatment, the function of the patients
The purpose of this study is to determine if the use of Virtual Reality as an intervention for patients following specific hand injuries will positively affect patients with decreased hand function and reduce pain and improve outcomes. Participants will be recruited from 3 different clinics in central Kentucky.
Non-invasiveness, avoidance of complications and comfort are important issues in the clinical management of conservatively treated distal radius and scaphoid fractures. To date, applying a plaster cast for approximately 6 weeks of immobilization is the gold standard. However, new 3D-technologies such as the design of Patient Specific Anatomical Braces (PSAB) will lead to a new paradigm of treatment. Swibrace has developed such anatomical, light, elegant and yet resistant braces. First, the fractured limb is scanned, the data then sent to a specifically designed software, printed in a 3D-printer and finally sent to the hospital for the patient's fitting. As these PSAB have not yet been tested on patients, the primary purpose of this study is to evaluate whether patient satisfaction with a 3D-printed PSAB differs from the one of traditionally treated patients in a plaster cast. (A pre-clinical study will be conducted with 10 healthy volunteers testing the 3D splint for 72h. Only if splint satisfaction will be ≥ 70% as measured by the self-designed "Adult Rated Splint Evaluation Questionnaire" (ARSEQ), the 3D splint will be tested in patients. Otherwise, adjustments to the splint will be made based on the healthy volunteers' feedback prior to its testing in patients.)
The study is designed to assess the use of intraoperative dexamethasone on postoperative analgesia and stiffness after open reduction and internal fixation of distal radius fractures. The idea is that the dexamethasone will aid in reducing postoperative swelling which will then improve pain control as well as overall function.
Non-steroidal anti-inflammatory drugs (NSAIDs), such as ibuprofen, are excellent medications for providing pain control in certain patients. There is some data to suggest that NSAIDs can be used to reduce postoperative pain and narcotic use in patients who had undergone carpal tunnel release. There are mixed results about the effect of bone healing in adult patients with broken bones. The investigators hypothesize that NSAID administration in the acute phase of distal radius fracture healing will be non-inferior for pain control and decrease the use of opioid analgesics compared to patients who take acetaminophen for pain control during this same time period. Furthermore, the investigators hypothesize that patients will have similar or better patient reported outcomes, range of motion, and strength with the administration of NSAIDs.
BACKGROUND: Wrist fractures are a common upper extremity injury treated by hand therapists. Currently, there is a dearth of published literature supporting the use Fluidotherapy® to improve pain and range of motion (ROM) in wrist fracture patients. \OBJECTIVE: This pilot study was conducted to determine the effects of one 15-minute bout of performing active range of motion (AROM) exercises in Fluidotherapy® (EXFT) versus AROM exercises (EX) alone on pain levels and AROM in wrist fracture subjects. METHODS: Eight subjects diagnosed with a wrist fracture (distal radius fracture, distal radius/ulna fractures, or distal ulna fracture) and referred to outpatient rehabilitation/occupational therapy were recruited upon his/her initial therapy evaluation. RESULTS: There were no significant differences between EX and EXFT groups in all outcome variables except for self-reported numeric pain scores (p=0.03*) and a trend towards significance in pronation AROM (p=0.06**). Even with a small sample size (n=8) there were significant differences in self-reported pain between the two groups. CONCLUSION: This study confirms that even after one 15-minute bout of AROM exercises in Fluidotherapy® treatment, patients report improved pain tolerance and may be useful in pain management techniques after a wrist fracture.
The occurrence of distal radius fractures is well known to be a sentinel event as these fractures are associated with 2 to 4 times increased risk of subsequent hip fractures in elderly patients. Studies have shown a significantly increased degree of postural sway in these patients, which is strongly associated with recurrent falls. The latest Cochrane systematic review also shows a lack of evidence on the effectiveness of current rehabilitation interventions. Low-magnitude high-frequency vibration (LMHFV) is a biophysical intervention that provides non-invasive, systemic mechanical stimulation and has been shown to improve muscle strength and balancing abilities in healthy, independent and active elderly women in our previous clinical study. Our animal studies have also shown LMHFV promoting myogenic proliferation and hypertrophy, muscle contractibility, and increased fast-fiber switching to muscle fiber type IIA.Previous rehabilitation studies have used clinical functional performance tests, which lack sensitivity and specificity in predicting impaired postural control. The Biodex Balance System SD consists of a dynamic balance platform interfaced with computer software, which offers objective and reliable tests for postural stability and fall risk. This study is a single-blinded, prospective randomized controlled trial to investigate the effect of 6 months of LMHFV after a distal radius fracture in elderly patients. Patients will be recruited and randomized to control or LMHFV group by envelope drawing of computer-generated random numbers. The intervention group will undergo LMHFV at 35Hz, 0.3g (peak to peak magnitude), displacement of <0.1mm, 20 min/day, at least 3 days/week for 6 months in community centres. Control group will remain in their habitual life style and no vibration used. Outcome assessments will be performed at baseline 0 days, 6 weeks, 3 months and 6 months. Outcome assessor and statistician will be blinded to group allocation. The primary outcome is the effect of LMHFV on postural stability. The Biodex Balance System SD is used to measure the static and dynamic ability of the subjects to maintain the center of balance. Secondary outcomes are the occurrence of fall for the patients in both groups, the health-related quality of life (SF-36), and Timed Up and Go test for basic mobility skills.
BACKGROUND. Distal radius fractures (FRD) are up to 17% of all diagnosed fractures and are the most commonly treated fractures in adult orthopedic patients. The management could be either conservative or surgical, depending on AO bone fracture classification. The principles of good treatment involves an anatomical reduction with a proper immobilization that keep the reduction. OBJECTIVE. Determine if percutaneous pinning for six weeks versus three has major complications in distal radius fractures.
The present collaboration study on the treatment of distal radius fractures is aimed to: (i) to compare non-operative treatment to volar plating in the treatment of initially malaligned distal radius fractures in patients aged 65 and older in terms of functional outcome measured with PRWE (ii) to compare non-operative treatment to volar plating in the treatment of distal radius fractures with early instability during follow-up, i.e., loss of reduction at 1 week (range 5 to 10 days) in patients aged 65 and older in terms of functional outcome measured with PRWE (iii)to compare pain, disability, quality of life, grip strength, and the number of complications after non-operative treatment and the initial and delayed operative treatment of distal radius fracture (iv) to assess the effect of pain catastrophizing score (PCS) on the functional outcome of non-operatively and operatively treated distal radius fracture (v) to assess the association between physical activity and the number of wrist movements measured with Axivity accelerometer and functional outcome measured with PROMs of non-operatively and operatively treated distal radius fractures (vi) to assess the effect of initial as well as the final radiological parameters on the functional outcome (vii) to assess the correlation of probability of radiological malalignment estimated by clinical prediction rule (EWC) with functional outcome measured with PRWE and PASS
The purpose of this study is to investigate patient related factors that contribute to increased risk of recurrent fractures and to investigate patient adherence to prescribed anti-osteoporotic drugs.