Clinical Trials Logo

Clinical Trial Summary

The goal of this study is to compare two FDA approved distal colonoscope attachment devices, in order to identify which device can increase adenoma detection rate the most without increasing procedure time or risk.


Clinical Trial Description

Although mortality from colon cancer is decreasing, it remains the second leading cause of cancer related death in the United States. There are multiple factors contributing to this decrease, such as increased awareness, improving screening techniques, etc.

Of the available modalities approved for colon cancer screening in the United States, colonoscopy is considered the gold standard. Colonoscopy has the advantage of being both diagnostic and therapeutic, allowing the removal of pre-cancerous polyps, before the polyps can transform into cancer. Colonic polyps can occur at any location from the rectum to the cecum. Colonoscopy has been shown to be more effective in decreasing incidence of cancer in the left colon but remains limited in the detection of right sided polyps /lesions 2. This difference based on location is thought to be due to several reasons. Typically the right side of the colon is less clean than the left side during colonoscopy, thereby impairing visualization of polyps. This problem has been overcome by incorporating a "split bowel preparation", which has not become standard of care. However, the problem of not being able to visualize polyps behind folds seen in the colon persists despite improvements in the quality of cleansing of the colon. Various endoscopic technologies have been introduced with the goal of assisting with the manipulation of such colonic folds, and thereby reducing chances of missing polyps behind fold. Two such colonoscope assisted devices including the distal transparent cap and the Endocuff endoscopic overtube.

The Endocuff overtube is a small device with flexible arms arranged in 2 rows. Each row has 8 short, soft arms projecting away from the device. These arms are used to peel back the colonic folds without causing physical damage to enable visualization behind colonic folds. The use of Endocuff overtube has shown promising results in terms of cecal intubation rate and time as well as adenoma detection rates 3.

The transparent cap attachment is a clear plastic device that fits at the end of the colonoscope and extends a short distance past the tip of the colonoscope. It aids in the manipulation of folds and in maintaining a suitable distance from the mucosa, with the goal of improving visualization. Although some studies comparing cap fitted colonoscopy to standard (non- attachment) colonoscopies have shown improved adenoma detection 4, others have shown no significant benefit 5.

Although, these devices have been compared with conventional colonoscopies (i.e without any distal attachment), to the investigator's knowledge, there are currently no studies that have compared these two distal colonoscope attachment devices head-to-head, and none has specifically evaluated effects on detection of right sided adenomas. Also, here at UCDavis, these devices are being used specifically in diagnostic colonoscopies for removal of large polyps and the choice of which specific device is used depends on level of comfort of the advanced endoscopist. The endoscopists participating in the investigators' study do not currently use these devices as part of their routine colonoscopies, thus it is important to provide head to head comparison of these devices to help guide management practice.

Therefore, the investigators' goal is to compare the Endocuff overtube assisted, transparent cap fitted, and non-cap fitted (standard) colonoscopy in patients presenting to UC Davis Medical Center for screening colonoscopies.

In addition, 2 of the 3 investigators will employ the water exchange method during for all arms of the trial, while the other investigator will employ the conventional air method of colonoscopy. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02665741
Study type Interventional
Source University of California, Davis
Contact
Status Completed
Phase N/A
Start date January 2016
Completion date February 2017

See also
  Status Clinical Trial Phase
Not yet recruiting NCT01214031 - Prospective Study for Evaluating Colon Polyp Histology With in Vivo Probe Based Confocal Laser Endomicroscopy N/A
Unknown status NCT01704820 - Right Sided Colon Polyp Miss Rate: Impact Of Retroflexion In The Right Colon N/A
Completed NCT01483040 - PeerScope B Systemâ„¢ Clinical Protocol N/A
Recruiting NCT01211132 - Cap Assisted Colonoscopy for the Detection of Colon Polyps N/A
Completed NCT00209573 - A Study of AQUAVAN® Injection Versus Midazolam HCl for Sedation in Patients Undergoing Elective Colonoscopy Phase 3
Completed NCT04666194 - A Pilot Randomized Trial of Polypectomy Techniques for 4-6 mm Colonic Polyps N/A
Completed NCT00417001 - Reduction of Conscious Sedation Requirements by Olfactory Stimulation N/A
Active, not recruiting NCT03735953 - Retroflexion in the Entire Colon for the Detection of Colon-related Diseases N/A
Recruiting NCT02332785 - Prospective Study of Colon Serrated Polyps
Completed NCT02325635 - A Prospective Trial of an Endoscopic Quality Improvement Project N/A
Completed NCT01487356 - Factors Associated With Short Withdrawal Time and Polyp Detection Rate During Colonoscopy N/A
Completed NCT00467922 - An Assessment of Goal-Directed Intraoperative Fluid Management in Hand Assisted Laparoscopic Colectomy Phase 3
Completed NCT05273697 - Clinical Study to Compare Cold Snare Underwater Polypectomy to Cold Snare Conventional Polypectomy for Colon Polyps [COLDWATER Study] N/A
Completed NCT01986699 - Laparascopic Assisted Colonoscopic Polypectomy N/A
Completed NCT02156557 - Study of KCC Peptide Application in the Colon Phase 1
Enrolling by invitation NCT02097394 - The Clinical Study on Combizym and Bifidobacteri to Prevent the Recurrence of Colon Polyps Phase 4
Completed NCT00492193 - Early Post-Op Recovery After Partial Large Bowel Resection N/A
Completed NCT00825292 - Detection and Classification of Colon Polyps Phase 2
Completed NCT02635217 - Same Day Bidirectional Endoscopies - Does the Sequence of Procedures or Choice of Insufflator Matter? N/A
Completed NCT02665299 - Plasma ctDNA in Patients Undergoing Diagnostic Colonoscopy N/A