Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT05222880
Other study ID # CR-6477
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date January 6, 2022
Est. completion date February 28, 2022

Study information

Verified date April 2023
Source Johnson & Johnson Vision Care, Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This is a single-masked, single-arm, dispensing clinical trial that will evaluate vision, eye health and fit acceptance.


Recruitment information / eligibility

Status Completed
Enrollment 140
Est. completion date February 28, 2022
Est. primary completion date February 28, 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 40 Years to 70 Years
Eligibility Inclusion Criteria: Potential subjects must satisfy all of the following criteria to be enrolled in the study: 1. Read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form. 2. Appear able and willing to adhere to the instructions set forth in this clinical protocol. 3. Be at least 40 years of age and not greater than 70 years of age at the time of consent. 4. Own a wearable pair of spectacles if required for their distance vision. 5. Be an adapted soft contact lens wearer in both eyes (i.e. worn lenses a minimum of 2 days per week for at least 6 hours per wear day, for 1 month or more duration). 6. Either already be wearing a presbyopic contact lens correction (e.g., reading spectacles over contact lenses, multifocal or monovision contact lenses, etc.) or if not respond positively to at least one symptom on the "Presbyopic Symptoms Questionnaire". 7. The subject's distance spherical equivalent refraction (vertex corrected if =-4.25 D) must be in the range of -1.25 D to -5.75 D or +0.75 D to +3.25 D in each eye. 8. The subject's refractive cylinder must be =0.75 D in each eye. 9. The subject's ADD power must be in the range of +0.75 D to +2.50 D. 10. The subject must have distance best corrected visual acuity of 20/20-3 or better in each eye. Exclusion Criteria: Potential subjects who meet any of the following criteria will be excluded from participating in the study: 1. Be currently pregnant or lactating. 2. Have any active or ongoing ocular or systemic allergies that may interfere with contact lens wear. 3. Have any active or ongoing systemic disease, autoimmune disease, or use of medication, which may interfere with contact lens wear. This may include, but not be limited to, diabetes, hyperthyroidism, Sjögren's syndrome, xerophthalmia, acne rosacea, Stevens- Johnson syndrome, and immunosuppressive diseases or any infectious diseases (e.g. hepatitis, tuberculosis). 4. Have any previous, or planned, ocular or intraocular surgery (e.g. radial keratotomy, PRK, LASIK, lid procedures, dacryocystorhinostomy, peripheral iridotomy/iridectomy, cataract surgery, retinal surgery, etc.). 5. Have a history of amblyopia, strabismus or binocular vision abnormality. 6. Use of any of the following medications within 1 week prior to enrollment: oral retinoid, oral tetracyclines, anticholinergics, oral phenothiazines, oral/inhaled corticosteroids. See section 9.1 for further examples. 7. Use of any ocular medication, with the exception of rewetting drops. 8. Have a history of herpetic keratitis. 9. Have a history of irregular cornea. 10. Have a history of pathological dry eye. 11. Have Participated in any contact lens or lens care product clinical trial within 30 days prior to study enrollment. 12. Be and employee or immediate family member of an employee of clinical site (e.g., Investigator, Coordinator, Technician). 13. Have any known hypersensitivity or allergic reaction to non-preserved rewetting drop solutions or sodium fluorescein. 14. Have clinically significant (Grade 2 or greater) corneal edema, corneal vascularization, corneal staining, tarsal abnormalities or bulbar injection, or any other corneal or ocular abnormalities which would contraindicate contact lens wear. 15. Have any current ocular infection or inflammation. 16. Have any current ocular abnormality that may interfere with contact lens wear.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
JJVC Investigational Multifocal Contact Lenses manufactured in senofilcon A C3
TEST Lens

Locations

Country Name City State
United States Birmingham Vision Care Bloomfield Hills Michigan
United States Vision Optique Houston Texas
United States Stam & Associates Eye Care Jacksonville Florida
United States Vue Optical Boutique Jacksonville Florida
United States Maitland Vision Center - North Orlando Ave Maitland Florida
United States Eye Associates of New York Manhattan New York
United States Optometry Group, LLC Memphis Tennessee
United States Kannarr Eye Care Pittsburg Kansas
United States Tallahassee Eye Center Tallahassee Florida
United States Tyler Eye Associates Tyler Texas
United States Sacco Eye Group Vestal New York
United States Dr. David W. Ferris & Associates Warwick Rhode Island

Sponsors (1)

Lead Sponsor Collaborator
Johnson & Johnson Vision Care, Inc.

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Binocular logMAR Visual Acuity Binocular visual acuity was measured on a logMAR (Logarithm of Minimal Angle of Resolution) scale under high luminance high contrast condition. At distance (4 meters), VA is assessed using ETDRS (Early Treatment Diabetic Retinopathy Study) charts; while near (40 cm) and intermediate (64 cm) assessments were made using reduced Guillon-Poling charts. Letter-by-letter results calculated the visual performance score for each chart read. LogMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20. 1-Week Follow-up
Primary CLUE Vision Score Subjective vision was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE vision score for each sphere stratum (Hyperope and Myope) was reported. 1-Week Follow-up
Primary Proportion of Eyes With Unacceptable Lens Fitting Contact lens fitting acceptance was assessed for each subject eye using a biomicroscope post lens insertion, the 1-week follow-up and any unscheduled visits. Lens fit was a binary variable where acceptable lens fit=1 and unacceptable lens fit=0. The proportion of eyes with unacceptable lens fit was reported. Up to 1-Week Follow-up
Primary Proportion of Eyes With Grade 3 or Higher Slit Lamp Findings Slit Lamp Findings (SLF) were assessed using a biomicroscope and was graded using the FDA grading scale (Grade: 0, 1,2, 3 and 4) with grade 0 represents the absence of findings and 1 to 4 representing successively worse findings (i.e. Grade 1 = trace, Grade 2 = Mild, Grade 3 = moderate and Grade 4 = severe). This was performed on each subject eye at every study visit (baseline, unscheduled visits and 1-week follow-up). The data was then dichotomized into two groups. Those with grade 3 or higher and those with grade 2 or lower. The proportion of eyes with SLF with grade 3 or higher was reported. Up to 1-Week Follow-up
Secondary CLUE Vision Score Subjective vision was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE vision score for each sphere stratum (Hyperope and Myope) was reported. 1-Week Follow-up
Secondary CLUE Comfort Score Subjective comfort was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE comfort score was reported. The pre-specified aim was not to compare comfort between the hyperope and myope subgroups, therefore, comfort scores were reported for both groups combined. 1-Week Follow-up
Secondary CLUE Handling Score Subjective Handling was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE handling score was reported. The pre-specified aim was not to compare comfort between the hyperope and myope subgroups, therefore, comfort scores were reported for both groups combined. 1-Week Follow-up
Secondary Proportion of Subject Achieving Optimal Lens Pair in 4 Lenses or Less The number of lenses to achieve the optimal pair for each subject was calculated as the original pair (2) plus all the required modifications to reach the optimal pair. In this study the minimum number of lenses per subject used was 2 where the maximum possible number of lenses used was 10. The data was dichotomized as Y=1 if the subject was able to achieve optimal lens pair in 4 lenses or lenses or less and 0 otherwise. A lens modification was performed if the subject reports unsatisfactory vision or was unable to obtain 20/30 distance visual acuity in both eyes. If the subject reported satisfactory vision with the lenses a modification was not required. However, based upon the investigator's findings on the measured visual acuity and/or over- refraction a modification may have been performed. Up to 1-Week Follow-up
See also
  Status Clinical Trial Phase
Completed NCT06019806 - Effects of Forward Head Posture Correction on Visual Acuity in Low Level Visually Impaired University Students N/A
Completed NCT04567186 - Evaluation of a Daily Disposable Novel Multifocal Contact Lens in a Hyperopic Population N/A
Completed NCT02568254 - Evaluation of Three Daily Disposable Contact Lenses N/A
Completed NCT01951703 - Senofilcon A Investigational Manufacturing Process N/A
Terminated NCT00637468 - EAGLE - Multicenter Study of the European Assessment Group for Lysis in the Eye Phase 3
Recruiting NCT04632901 - A New Parameter for the Assessment of Distance Visual Capacity: the Critical Visual Acuity (CVA)
Active, not recruiting NCT03747601 - Temporal Interference Brain Stimulation N/A
Completed NCT06131476 - Clinical Investigation of Visual Acuity in Contact Lens Wearers After Instillation of a Lipid- Based Lubricating Eye Drop Phase 1
Recruiting NCT05414565 - Post-Market Study of Alcon Intraocular Lenses
Completed NCT05056870 - Clinical Evaluation of Spherical Soft Contact Lenses, Toric Soft Contact Lenses and Spectacles in Low Astigmats N/A
Completed NCT04615507 - Evaluation of a Daily Disposable Novel Multifocal Contact Lens in a Myopic Population; Part 2 N/A
Completed NCT05099380 - Validation of Senofilcon A With New UV / HEV Filter N/A
Completed NCT03713281 - Evaluation of a Toric Multifocal Contact Lens Manufactured in Etafilcon Material in a Low ADD Hyperopic Population
Completed NCT05582304 - Role of Glare and Spectral Filtering on Contrast Sensitivity: A Pilot Study N/A
Completed NCT03742271 - Evaluation of Senofilcon A With New UV-blocker on a Neophyte Population N/A
Completed NCT04995055 - Evaluation of Multifocal Contact Lens Designs With and Without an HEV Blocker on Visual Function N/A
Completed NCT05554640 - Clinical Performance of Two Daily Disposable Silicone Hydrogel Contact Lenses N/A
Completed NCT01926704 - MTF Image Modifications N/A
Completed NCT04649606 - Dynamic Characterisation of Meibomian Gland Structure
Completed NCT05101252 - Comparison of a Daily Disposable Multifocal Contact Lens to a Marketed Product N/A