Clinical Trial Details
— Status: Completed
Administrative data
NCT number |
NCT05209945 |
Other study ID # |
WBVTVR |
Secondary ID |
|
Status |
Completed |
Phase |
N/A
|
First received |
|
Last updated |
|
Start date |
November 27, 2021 |
Est. completion date |
December 31, 2021 |
Study information
Verified date |
January 2022 |
Source |
Istanbul Physical Medicine Rehabilitation Training and Research Hospital |
Contact |
n/a |
Is FDA regulated |
No |
Health authority |
|
Study type |
Interventional
|
Clinical Trial Summary
Whole-body vibration (WBV) has beneficial neuromuscular effects on muscle strength increase.
Supraspinal, spinal, and peripheral mechanisms have been proposed to explain these beneficial
effects. The most commonly proposed explanatory mechanism is spinal segmental reflexes.
However, the neuronal circuit and receptors of the reflex response have not been defined
precisely. A group of researchers found that the reflex system is the Tonic vibration reflex
(TVR) under the neuromuscular effects of WBV; Other researchers claim that WBV activates a
different spinal reflex than TVR. Tonic vibration reflex is a polysynaptic reflex that occurs
as a result of muscle spindle activation, in which more than 100 Hz vibrations are applied to
the belly or tendon of the muscle. A group of researchers argues that WBV activates the
spinal reflex response, but this reflex response is different from TVR. According to them,
WBV-induced reflex (WBV-IR) response latency is longer than TVR latency. WBV activates TVR at
very attenuated amplitude; WBV activates a different spinal reflex with longer latency at
medium and high amplitude vibration. They reported that although the H-reflex, T-reflex, and
TVR latency was longer in the spastic soleus muscle than normotonic soleus muscle, where the
muscle spindle and Ia afferent pathway were hyperactive. However, the WBV-IR latency was
similar in both spastic and normotonic soleus muscle. According to our hypothesis, the reflex
system activated by WBV changes depending on vibration frequency: if the high-frequency
(100-150 Hz) WBV is applied, the tonic vibration reflex is activated; if the low-frequency
(30-40 Hz) WBV is applied, the bone myoregulation reflex is activated. The purpose of this
research is to test this hypothesis.
Description:
Seven healthy recreationally active males between the ages of 26 and 35 volunteered to
participate in this study. All subjects received pre-study informed consent. All experimental
procedures were designed with the Helsinki declaration in mind and approved by the local
ethics committee. All subjects performed a familiarization trial to acclimate subjects to the
WBV stimulus. WBV-IR and TVR latency of soleus muscle were then measured in the quiet
standing position. The vibrations (WBV or tendon) sequence were applied randomly to negate
any order/time effect. The subject rested for five minutes between the WBV and tendon
vibration. The WBV application was delivered using a PowerPlate Pro5 device (PowerPlate
International, Amsterdam, The Netherlands). First, 30 Hz, low amplitude (1 mm) vibration with
a duration of 30 seconds was applied to each subject for familiarization purposes. After
three minutes of rest, low-amplitude (1 mm) WBV testing was performed in random order in
quiet standing positions. In a WBV set, three different vibration frequencies (30, 35, and 40
Hz), each lasting for 30 s with 3-s rest intervals, were delivered. The local vibration was
applied to the mid-point of the right Achilles tendon by using a custom-made vibrator. The
head of the tendon vibrator was in light contact with the underlying skin. Tendon vibrations
were applied by the same researcher. Three different vibration frequencies (100, 135, and 150
Hz) were delivered, lasting for 30 s with 3-s rest intervals. A local vibration was applied
to the right heel using the same custom-made vibrator. Tendon vibrations were applied by the
same researcher. Three different vibration frequencies (100, 135, and 150 Hz) were delivered,
lasting for 30 s with 3-s rest intervals.
The surface electromyography (SEMG) recorded from the soleus and acceleration data were
collected simultaneously using data acquisition and analysis system (PowerLab ® software,
ADInstruments, Oxford, UK). Disposable self-adhesive bipolar Ag/AgCl (Covidien Kendall,
Dublin, Ireland) surface electrodes were placed on the right soleus belly 4 cm apart. The
skin overlying the muscle was shaved, light abrasion was applied, and the skin was cleaned
with alcohol to reduce the skin resistance. To determine TVR latency, a light (2.9 g)
piezoelectric accelerometer (LIS344ALH, ECOPACK®, Mansfield, TX, USA) was firmly fixed using
adhesive tape on the skin overlying the right Achilles tendon. To determine WBV-IR latency,
an identical accelerometer was firmly mounted on the WBV platform. The acceleration and SEMG
signals were recorded at a sampling frequency of 20 kHz. Accelerometer recordings were
filtered with a high-pass filter set at 5 Hz. SEMG data obtained during WBV were bandpass
filtered at 80-500 Hz to reduce vibration-induced movement artifacts and then full-wave
rectified. Similarly, SEMG data obtained during tendon vibration were bandpass filtered at
160-500 Hz and then full-wave rectified. WBV-IR and TVR latencies were then calculated by
using the cumulative average method.
An electronic reflex hammer (Elcon, Germany) was used to determine T-reflex latency. All
latencies were normalized to the body height of each participant.
Latency was expressed as milliseconds (ms).