Clinical Trials Logo

Clinical Trial Details — Status: Terminated

Administrative data

NCT number NCT02735096
Other study ID # ICTP216
Secondary ID
Status Terminated
Phase N/A
First received
Last updated
Start date July 2016
Est. completion date October 2016

Study information

Verified date March 2018
Source Innervo Technology LLC
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The human body uses vestibular feedback in coordination with visual and somatosensory information to maintain balance and posture. However, various inner-ear disorders due to aging, drug toxicity, viral infections, and injury, etc., may result in loss of vestibular feedback, which makes it difficult for an individual to maintain balance. This study investigates the use of a hidden and noninvasive balance device EquiCue™ V1 developed by Innervo Technology for vestibular substitution. EquiCue™ V1 is a retainer-like intraoral electronic balance aid entirely worn inside the oral cavity and provides in-situ sensory feedback of head tilting and motion on the roof of the mouth. The feedback is delivered by applying small and controlled electrical pulses at precise locations on the palatal surface according to an encoded pattern. This pilot study is to determine how this alternative sensory feedback on the roof of the mouth can be used to improve balance for patients with vestibular loss.


Description:

Background

Vestibular imbalance is prevalent in the United States and around the world. According to NIDCD, 4% (8 million) of American adults report a chronic problem with balance (visit vestibular.org for more information). The leading cause of imbalance is vestibular dysfunction. Various vestibular disorders due to aging, diseases, ototoxicity, and injuries, etc. can cause damage or degradation of the vestibular system, resulting in loss of vestibular feedback. Symptoms associated with vestibular loss include: difficulty maintaining straight posture; stumbling or unable to walk straight; lose balance on uneven surfaces or under dim lighting; floating sensation and tendency to look downward to confirm the location of the ground. Vestibular imbalance greatly increases risk of falling and has such disabling effects ranging from reduced activity levels to total loss of mobility.

Vestibular rehabilitation therapies (VRT) may help vestibular patients to compensate with vision and proprioception. However, such compensation is not adequate because the brain often needs a reliable reference in order to use visual and somatosensory information for perception of self-motion and spatial orientation. Consequently, many patients with vestibular imbalance fail to compensate, especially those with profound vestibular loss. Even those who respond to VRT may experience constant physical and mental stress due to overreliance on vision and proprioception that can be misleading in busy environments.

EquiCue™ Intraoral Balance Aid

The intraoral balance aid EquiCue™ V1 is a hidden and noninvasive balance device that vestibular patients can use in various indoor and outdoor activities. It is a retainer-like device entirely worn inside the oral cavity, with no need of surgical implantation, and can be removed when not in use. The device provides in-situ sensory feedback of head tilt and motion by applying small electrical pulses on the roof of the mouth. By sensing the feedback from the device, an individual with vestibular loss can have better judgment of the tilt and motion of the head and make physical adjustment accordingly for better balance of the body. Since the device does not cause alteration to the appearance of the user, patients may use it in public places such as shopping malls, supermarkets, and metro stations, while offering balance assistance and improved postural stability and gait in these busy environments.

Human Subject Study

The current study is an initial stage of a clinical trial on the use of EquiCue™ for patients with vestibular imbalance. The hypothesis is that EquiCue™ can at least partially substitute the lost vestibular function and therefore helps a vestibular patient to achieve better postural stability in daily activities. The basic questions regarding the technology are: 1) How to represent head movement using electrical pulses on the palate; 2) Whether the electrotactile presentation on the palate can be reliably recognized and used for balance control. The study also helps to understand the role of multisensory integration on balance, especially the impact of alternative sensory feedback on the balance system.

Subjects participating in the study will be expected to wear a custom-made retainer-like device and perform movements to test their balance. If a patient is determined to be a suitable subject, the sensitivity profile on the palate of the patient will be measured. After an EquiCue™ intraoral device is custom made, the patient will be asked to fit the device inside the mouth, and verify the basic functionality of the device by identifying direction, perceived intensity, and sensory characteristics of stimuli from the device. The subject will then go through 3-4 sessions of training and testing in which the subject tries to associate the feedback with head movement and to integrate the feedback with other senses to achieve a better spatial orientation and balance. The improvement in balance and gait with the device will be evaluated by using standard tests on balance platforms (Computerized Dynamic Posturography) and Dynamic Gait Index. Tests will be made without wearing the device at the beginning and wearing the device at the end of each training session.


Recruitment information / eligibility

Status Terminated
Enrollment 4
Est. completion date October 2016
Est. primary completion date October 2016
Accepts healthy volunteers No
Gender All
Age group 18 Years to 85 Years
Eligibility Inclusion Criteria:

1. English speaking adults with ages between 18-85.

2. Patients with imbalance resulted from vestibular loss or vestibulopathy.

3. Priority given to those who took vestibular rehabilitation therapy but without satisfactory improvement.

Exclusion Criteria:

1. Inability to follow instructions.

2. Any visible abnormalities on the hard palate that prevent use of the palatal device.

3. Any mental or physical illness beyond the secondary effects of vestibular loss that prevent recognition or effective use of the alternative feedback.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
EquiCue (Intraoral Electronic Balance Aid)
When the device is worn, a subject will receive small electrical pulses on roof of the mouth as alternative feedback of head tilting or movement.

Locations

Country Name City State
United States MU ENT Hearing and Balance Center Columbia Missouri
United States Blue Ridge Physical Therapy Independence Missouri

Sponsors (3)

Lead Sponsor Collaborator
Innervo Technology LLC Blue Ridge Physical Therapy, University of Missouri-Columbia

Country where clinical trial is conducted

United States, 

References & Publications (7)

Agrawal Y, Carey JP, Della Santina CC, Schubert MC, Minor LB. Disorders of balance and vestibular function in US adults: data from the National Health and Nutrition Examination Survey, 2001-2004. Arch Intern Med. 2009 May 25;169(10):938-44. doi: 10.1001/archinternmed.2009.66. Erratum in: Arch Intern Med. 2009 Aug 10;169(15):1419. — View Citation

Brown KE, Whitney SL, Wrisley DM, Furman JM. Physical therapy outcomes for persons with bilateral vestibular loss. Laryngoscope. 2001 Oct;111(10):1812-7. — View Citation

Danilov YP, Tyler ME, Skinner KL, Hogle RA, Bach-y-Rita P. Efficacy of electrotactile vestibular substitution in patients with peripheral and central vestibular loss. J Vestib Res. 2007;17(2-3):119-30. — View Citation

Dozza M, Horak FB, Chiari L. Auditory biofeedback substitutes for loss of sensory information in maintaining stance. Exp Brain Res. 2007 Mar;178(1):37-48. Epub 2006 Oct 5. — View Citation

Tang H, Beebe DJ. An oral tactile interface for blind navigation. IEEE Trans Neural Syst Rehabil Eng. 2006 Mar;14(1):116-23. — View Citation

Tang H; Beebe DJ. Design and microfabrication of a flexible oral electrotactile display. Journal of Microelectromechanical Systems. 2003 Feb;12(1):29-36.

Wall C 3rd, Merfeld DM, Rauch SD, Black FO. Vestibular prostheses: the engineering and biomedical issues. J Vestib Res. 2002-2003;12(2-3):95-113. Review. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Equilibrium Score Equilibrium scores for each trial for each condition from Sensory Organization Test (EquiTest). Conditions: 1-6; with or without using EquiCue intraoral balance aid. Equilibrium scores were generated from the EquiTest CDP (computerized dynamic posturography) platform to assess standing balance of a patient ranging from 0 (all falls) to 100 (perfect balance with no sway), with higher scores indicating better balance performance. An equilibrium score of 70 and above is considered normal. July 2016 - October 2016 (~ 4 months)
Secondary Perceived Intensity Level The perceived Intensity level (from 0 to 5) as judged by a patient in response to pulsed stimuli applied on the palatal surface after adjustment of device settings for that patient. 1 - barely perceptible, 2 - weak, 3 - good, 4 - strong, 5 - painful. July 2016 - October 2016 (~ 4 months)
Secondary Dynamic Gait Index A subject's gait is evaluated by a physical therapist when no device is worn and when alternative sensory feedback of head movement is presented to the patient using the device. 7 walking exercises were administrated for each DGI test, with a score in the range of 0 - 3 (0 for severely impaired and 3 for normal gait) for each exercise, and a total score in the range of 0 - 21 for each test. July 2016 - October 2016 (~ 4 months)
Secondary Analog Visual Scale for the Perceived Frequency of Stimulation Pulses A patient's assessment of the speed of pulses to quantify perceptual difference in the pulse frequencies of the feedback on the palatal surface. July 2016 - October 2016 (~ 4 months)
See also
  Status Clinical Trial Phase
Enrolling by invitation NCT04196933 - Analysis of Vestibular Compensation Following Clinical Intervention for Vestibular Schwannoma N/A
Completed NCT04894929 - Comprehensive Geriatric Assessment in the Monitoring of Functional Improvement N/A
Recruiting NCT04353115 - A Serious Game to Rehabilitate Gaze Stability in Children With Vestibular Deficit
Recruiting NCT04053829 - Feasibility and Acceptability of HOLOBalance Compared to Standard Care in Older Adults at Risk for Falls N/A
Completed NCT03163901 - The Effect of OMT on Functional Outcomes and Anti-inflammatory Biomarkers in Mild to Moderate Traumatic Brain Injury N/A
Active, not recruiting NCT04479761 - Sensory Integration of Auditory and Visual Cues in Diverse Contexts N/A
Recruiting NCT03624283 - Interventions for Residual Dizziness After Successful Repositioning Maneuvers in Patients With BPPV N/A
Recruiting NCT03690817 - Hearing Loss, Vestibular Loss and Cognitive Performance
Completed NCT03555370 - Vestibular Treatment in Adolescents Following Sport Related Concussion N/A
Not yet recruiting NCT05322538 - Menier's Disease - Bone Density Study N/A
Completed NCT05795530 - Vestibular Function in Cochlear Implants
Completed NCT03330262 - Head-Mounted Vibrotactile Prosthesis for Patients With Chronic Postural Instability N/A
Not yet recruiting NCT06177132 - Vestibular Infant Screening - Rehabilitation N/A
Completed NCT03952936 - Vestibular Rehabilitation for Chronic Central Vestibular Deficits: A Case Study N/A
Recruiting NCT05436067 - Individualized Vestibular Rehabilitation for Elderly With Self-Management and Gaming Elements N/A
Not yet recruiting NCT06350669 - App-supported Vestibular Rehabilitation (RCT) N/A
Completed NCT03951584 - Prognosis of Vestibular Dysfunction in Patients With Idiopathic Sudden Sensorineural Hearing Loss
Active, not recruiting NCT05793216 - VestibulOTherapy: Vestibular Impact on Learning N/A
Recruiting NCT05741515 - Vestibular Balance Therapy Intervention for Children N/A
Recruiting NCT04851184 - Dose of Vestibular Rehabilitation for Vestibular Hypofunction N/A