Clinical Trials Logo

Clinical Trial Summary

To evaluate whether T Wave Alternans can predict ventricular arrhythmias and sudden cardiac death (SCD) in a prospective epidemiologic natural history study.

The prospective epidemiologic pilot study included 550 patients that had left ventricular dysfunction and no history of sustained ventricular arrhythmias. The primary hypothesis tested was whether there was an increased risk of having an arrhythmic event when T Wave Alternans was present in the patient. The secondary aims included comparing risk due to T Wave Alternans between the ischemic patients and non-ischemic patients and assessing whether T Wave Alternans remained an independent predictor of risk upon adjustment for other known risk factors for arrhythmic events such as ejection fraction, ventricular ectopy, NSVT, average NN interval, and RR interval variability.

The study approach was a standard epidemiologic surveillance technique. The subject population consisted of individuals with Class I to III heart failure who will underwent a TWA and Holter monitor test and then were followed for up to two years or until arrhythmic events occured.


Clinical Trial Description

Sudden cardiac death accounts for approximately 400,000 deaths each year in the United States and remains a health problem of epidemic proportions. Most sudden cardiac deaths are caused by fatal ventricular arrhythmias. An effort aimed at the primary prevention of sudden cardiac death requires efficient identification of patients who are at high enough risk for having these arrhythmias to warrant aggressive prophylactic therapy. A number of recently completed, randomized clinical trials have demonstrated that an implantable cardiac defibrillator (ICD) can prevent sudden cardiac death in a highly selected group of high-risk patients. When these trials are viewed together, the only patients in whom the prophylactic implantation of an ICD has proven benefit are those patients identified by documented, spontaneous or inducible, sustained ventricular arrhythmias.

Two randomized treatment trials (MADIT II, SCD-HEFT) tested the hypothesis that implantation of an ICD would reduce mortality in patients with congestive heart failure (CHF) and left ventricular dysfunction without any further risk tratification. However, the implications of these two trials-implantation of an ICD in every patient with CHF-were unlikely to be accepted either by the medical community or by health care payers. More efficient methods of risk stratification were necessary to identify those patients with CHF who were most likely to benefit from prophylactic treatment with an ICD.

T Wave Alternans is a subtle every-other-beat variation in electrocardiographic T waves that is prognostic of patients at high risk for life-threatening cardiac arrhythmias and sudden cardiac death. It has recently been shown that T Wave Alternans (TWA) measured during exercise is strongly associated with inducible monomorphic CVT and with subsequent spontaneous arrhythmic events. This preliminary data suggest that TWA may be an efficient and non-invasive surrogate for electrophysiologic testing to screen patients who may be at high-risk for sudden cardiac death. ;


Study Design

Observational Model: Cohort, Time Perspective: Prospective


Related Conditions & MeSH terms


NCT number NCT00006501
Study type Observational
Source Columbia University
Contact
Status Completed
Phase N/A
Start date January 2003
Completion date February 2012

See also
  Status Clinical Trial Phase
Completed NCT04624412 - Different Intensities of Continuous Aerobic Exercises in Cardiac Rehab Phase 2 N/A
Completed NCT05563701 - Evaluation of the LVivo Image Quality Scoring (IQS)
Recruiting NCT04561908 - Transcatheter Microguidewire Drilling for Transseptal Left Atrial Access N/A
Active, not recruiting NCT06190743 - Perception of Cardiovascular Risk
Completed NCT04562636 - Evaluating a Messaging Campaign in the United States N/A
Completed NCT04580095 - Artificial Intelligence for Improved Echocardiography N/A
Recruiting NCT03277365 - MyGeneRank: A Digital Platform for Next-Generation Genetic Studies N/A
Active, not recruiting NCT05553106 - Evaluation of Cognitive Status, Kinesiophobia, Physical Activity Level, and Functional Performance in Coronary Intensive Care
Completed NCT03429920 - Effect of Fermented Soy Based Product on Cardiometabolic Risk Factors N/A
Recruiting NCT04390672 - Multivessel TALENT N/A
Enrolling by invitation NCT03314818 - Natural History of Carotid Plaque as Determined by 3D Ultrasound N/A
Withdrawn NCT03289104 - Improving Sternal Healing After Cardiac Surgery: Sternal Wire vs ZIPFIX N/A
Completed NCT02917213 - Imaging Silent Brain Infarct And Thrombosis in Acute Myocardial Infarction
Completed NCT02046902 - Developing and Testing a Personalized Evidence-based Shared Decision-making Tool for Stent Selection
Completed NCT01944254 - The Precision of Pulmonary Artery Cardiac Output-measurements in Spontaneously Breathing Patients N/A
Completed NCT01909349 - Web-based Aftercare Intervention for Cardiac Patients N/A
Recruiting NCT01457586 - Hemoderivative Imputable Complications in Initial Uncomplicated Heart Surgery Phase 4
Recruiting NCT01207167 - Mediators of Atherosclerosis in South Asians Living in America
Recruiting NCT01541163 - Heart and Ischemic STrOke Relationship studY N/A
Terminated NCT00968383 - Cardiovascular Magnetic Resonance for the Occluded Infarct-Related Artery Treatment N/A