Clinical Trials Logo

Ventilation-Associated Pneumonia clinical trials

View clinical trials related to Ventilation-Associated Pneumonia.

Filter by:
  • Completed  
  • Page 1

NCT ID: NCT02534974 Completed - Clinical trials for Ventilation-associated Pneumonia

Impact of the Addition of a Device Providing Continuous Pneumatic Regulation of Tube Cuff Pressure to an Overall Strategy Aimed at Preventing Ventilator-associated Pneumonia in the Severe Trauma Patient. A Multicentre, Randomised, Controlled Study.

AGATE
Start date: July 31, 2015
Phase: N/A
Study type: Interventional

Ventilation-associated pneumonia is the main site of healthcare-associated infections in the severe trauma patient, with a mean incidence rate of 35%. Ventilator-associated pneumonia increases morbi-mortality, length of stay in intensive care and overall management costs. As was recalled by the jury of the 2008 SFAR-SRLF consensus conference on the prevention of nosocomial infections contracted in intensive care, success in this preventive endeavour depends on a number of measures: orotracheal intubation route, maintaining tube cuff pressure between 25 and 30 cm H2O, maintaining a semi-seated position ≥30°, nasal and oropharyngeal care at regular intervals, striving to avoid unscheduled extubation, and use of a written sedation-analgesia algorithm allowing for early weaning from ventilation. Devices ensuring continuous pneumatic control of tube cuff pressure are more efficient in maintaining tracheal balloon pressure than intermittent adjustments using a hand-held manometer. In one study, these devices clearly facilitated diminution of microaspiration of gastric contents and of ventilator-associated pneumonia incidence density (9.7 vs. 22 VAP/1000 days of mechanical ventilation; p = 0.005). The investigators are putting forward the hypothesis that by adjoining a device providing continuous pneumatic regulation of tube cuff pressure to an overall strategy aimed at ventilator-associated pneumonia prevention (including semi-recumbent position ≥30°, oro-nasal-pharyngeal care at regular intervals and reduced risk exposure) can decrease VAP incidence by 50% in severely traumatised patients whose condition necessitates mechanical ventilation of an expected duration exceeding 48h. Ours is the first large-scale study to evaluate the interest of an innovative technology bundle on decrease of ventilator-associated pneumonia incidence in one of the intensive care populations the most at risk, namely severe trauma patients, a population presently benefiting from the other recommended preventive measures.

NCT ID: NCT01137487 Completed - Clinical trials for Ventilation-Associated Pneumonia

Study of Impact of Not Measuring Residual Gastric Volume on Nosocomial Pneumonia Rates

NUTRIREA1
Start date: May 2010
Phase: N/A
Study type: Interventional

Early enteral feeding is a key component of the management of critically ill patients receiving mechanical ventilation. However, enteral feeding has been associated with serious complications such as aspiration followed by ventilator-associated pneumonia (VAP). Many critically ill patients experience poor tolerance of early enteral nutrition because of impaired gastric motility, which leads to a sequence of delayed gastric emptying, increased gastric volume, gastroesophageal reflux, vomiting, aspiration, and VAP. Routine monitoring of residual gastric volume (RGV) to minimize the risk of aspiration is standard practice. RGV is assumed to reflect gastric content, with high RGVs indicating impaired gastric emptying that requires discontinuation of enteral feeding in order to prevent aspiration.However, RGV measurement is neither standardized nor validated. The cut-off value that may indicate an increased risk of aspiration and therefore a need for discontinuing enteral feeding has not been determined, and cut-offs used in studies have ranged from 150 to 500 ml. No data are available to support a correlation between RGV and the rates of adverse events. In experimental studies, RGV failed to correlate with vomiting, aspiration, or VAP. The investigators hypothesize that RGV monitoring fails to decrease the risk of VAP and leed to inappropriate interruptions in enteral feeding with a risk of underfeeding. To assess the effects of not measuring RGV on VAP and enteral feeding delivery, the investigators designed a prospective randomized controlled study.