Clinical Trials Logo

Clinical Trial Summary

1. Evaluated Patients: 5 patients (Convenience sample: non-blinded, non-randomised) Selection follows documented hospital protocols for routine catheterisation 2. Measured Patients: 30 patients (Convenience sample: non-blinded and non-randomised) - 20 who receive the M4D coated catheter. - 10 who receive the standard uncoated catheters used in routine patient care.


Clinical Trial Description

1. Evaluated Patients: 5 patients (Convenience sample: non-blinded, non-randomised) Selection follows documented hospital protocols for routine catheterisation 2. Measured Patients: 30 patients (Convenience sample: non-blinded and non-randomised) - 20 who receive the M4D coated catheter. - 10 who receive the standard uncoated catheters used in routine patient care. 1) Evaluation (5 patients, coated catheter) A convenience sample of patients will be selected to receive the Camstent coated catheter for their routine care. These enrolments are drawn from among those recommended for routine catheterisation, for up to 28 days and in accordance to existing hospital protocols. There is no change to the routine protocols for insertion, maintenance, withdrawal, or documentation of the patient's catheterisation. Following use, the catheter is discarded according to the hospital's procedures. Staff questionnaires will be completed to capture general use information. These will document the opinions of the nurse inserting and withdrawing the catheter, and may include questions for the patient, to record their experience. There will be no collection of patient information, and no analysis of the discarded catheter. 2) Measurement (10 patients receiving uncoated catheters, 20 patients receiving coated catheters) The data collection will include 10 patients who have received the standard hospital issued uncoated catheter and 20 patients who have received the Camstent coated catheter. There will be no randomisation and no blinding. The first 10 patients needing routine urinary catheterisation to drain their bladder for up to 28 days whilst in hospital will receive the routine hospital issued catheter and will looked after by hospital and staff as standard practice. The next 20 patients needing routine urinary catheterisation to drain their bladder whilst in hospital will receive a coated catheter. There will be no change to the intended use of the catheter for patients where it is deemed medically necessary to drain urine from the urinary bladder via the urethra using the catheter device for up to 28 days. There will be no change to any patient care or catheterisation procedures. All 30 catheters will be sent to a laboratory for surface examination rather than immediately disposed of as medical waste. Harvested catheters will be bagged in an airtight plastic bag and tagged with a record identifier. A record identifier will be used to establish catheter traceability and duration, and will not compromise patient anonymity. The catheter will be kept refrigerated and transported to the analysis laboratory at Nottingham University within two days. At the Nottingham Laboratory, the catheters will be subjected to qualitative and quantitative analysis to determine the percentage of biofilm coverage on the surface. This will initially be achieved using staining followed by microscopic visual examination of the catheter surface, and images taken of any surface encrustation. For Fluorescence Microscopy, the procedure will be: 1. Cut the catheter into segments then wash three times in ~15 ml of PBS with gentle agitation. 2. Transfer the washed catheter segments into the wells of a sterile 24 well plate and stain with SYTO17 Red Fluorescent Nucleic Acid Stain. 3. Segments will be imaged using a laser scanning confocal microscope using a 10 X objective lens over a 1024 μm x 1024 μm area. 4. A z-section will be imaged (each section is 4μm apart with 36 images taken over 140μm) such that the entire curved surface is imaged. The coverage data will then be taken from a maximum intensity z-projection. 5. Data analysis will be carried out in ImageJ using the maximum intensity z-projection images. 6. Images will be converted to 8-bit greyscale images, a threshold applied to select the data correctly and the biofilm coverage measured. 7. The percentage of coverage for each sample will be computed as (Light) / (Light + Dark) * 100%. Aggregate descriptive statistics will be calculated, and biofilm coverage will be plotted against the duration of catheterisation as a scattergram. The study is not powered to permit statistical analysis. Prior laboratory experiments predict that the difference in biofilm coverage could exceed 80%. If larger differences are seen in harvested catheters, then a Total Cell Count assay, in which the biofilm is sonicated free of the surface and then assessed through serial dilution, may be substituted for Fluorescence Microscopy. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05513677
Study type Interventional
Source Camstent Ltd.
Contact
Status Completed
Phase N/A
Start date August 14, 2018
Completion date December 30, 2021

See also
  Status Clinical Trial Phase
Recruiting NCT04495699 - Asymptomatic Renal Calculi in Recurrent Urinary Tract Infections
Terminated NCT05254808 - EXtended Use of FOsfomycin for the Treatment of CYstitis in Primary Care Phase 3
Completed NCT03680612 - Cefepime/AAI101 Phase 2 Study in Hospitalized Adults With cUTI Phase 2
Completed NCT03282006 - Treating Pyelonephritis an Urosepsis With Pivmecillinam Phase 4
Completed NCT03526484 - The Utility of Urinalysis Prior to In-Office Procedures N/A
Completed NCT05397782 - Effects of Flourish on Recurrent Urinary Tract Infection N/A
Completed NCT05018546 - Safety and Efficacy of Different Irrigation System in Retrograde Intrarenal Surgery N/A
Completed NCT03687255 - Safety and Efficacy Study of Cefepime-AAI101 in the Treatment of Complicated Urinary Tract Infections Phase 3
Recruiting NCT05227937 - Single Dose Amikacin for Uncomplicated Cystitis in the ED: A Feasibility Study
Completed NCT02864420 - Hospitalization at Home: The Acute Care Home Hospital Program for Adults N/A
Completed NCT03131609 - Avoiding Bacterial Contamination of Clean Catch Urine Cultures in Ambulatory Patients in the Emergency Department
Completed NCT01911143 - A Retrospective, Blinded Validation of a Host-response Based Diagnostics N/A
Completed NCT01333254 - A Trial of Different Methods for Bladder Drainage in Hip Surgery Patients N/A
Terminated NCT00594594 - Adjuntive Probiotic Therapy in Treating Urinary Tract Infections in Spinal Cord Injury Phase 1
Completed NCT00216853 - A Study of Vaginal MicroFlora and Immune Profiles of Patients With Recurrent Urinary Tract Infection N/A
Completed NCT00787085 - The Significance of Funguria in Hospitalized Patients N/A
Completed NCT05719753 - The Effectiveness of a Bacteriophobic Coating on Urinary Catheters N/A
Recruiting NCT05415865 - The Effect of Local Anesthetic Solution in the Bladder Prior to Botox Injections in the Bladder Phase 3
Not yet recruiting NCT05880329 - DIagnoSing Care hOme UTI Study
Recruiting NCT04615065 - Acutelines: a Large Data-/Biobank of Acute and Emergency Medicine