View clinical trials related to Unstable Angina Pectoris.
Filter by:The introduction of drug-eluting stents (DES) in the treatment of coronary artery disease has led to a significant reduction in morbidity. However, the first generation of these devices had no positive impact on the mortality after PCI (compared to bare metal stents), which was greatly attributed to a somewhat increased incidence of late and very late stent thrombosis. Concerns about the role of durable polymers as a potential trigger of inflammation and finally adverse events also led to the development of DES with bioresorbable coatings, which leave after degradation of the coating only a bare metal stent in the vessel wall that does not induce an inflammatory response. While such bioresorbable polymer DES are increasingly used in clinical practice, data from head-to-head comparisons between bioresorbable polymer DES with a contemporary highly flexible new generation permanent polymer coated DES.
Rationale: The introduction of drug-eluting stents (DES) in the treatment of coronary artery disease has led to a significant reduction in morbidity but there are further demands on DES performance. Such demands are an optimized performance in very challenging coronary lesions; third generation DES were developed in an effort to further improve DES performance in such challenging lesions. Two CE-certified third generation DES (Resolute Integrity and Promus Element stents) are currently available; there are no data that indicate an advantage of one of these DES over the other. Objective: To investigate whether the clinical outcome is similar after implantation of the Promus Element versus the Resolute Integrity stent (non-inferiority hypothesis). Study design: Multicenter, prospective, randomized single-blinded study. Study population: Patients who require percutaneous coronary interventions (PCI) for the treatment of coronary stenoses with an indication for DES use, according to current guidelines and/or the operators clinical judgement. All clinical syndromes will be included. Intervention: In patients who are eligible for DES implantation, the type of DES implanted will be randomized (Resolute Integrity stent versus Promus Element stent). At the start of the study, both DES will also be used in routine clinical practice. Main study endpoints: The primary endpoint is the incidence of target vessel failure at one year follow-up. Target vessel failure (TVF) is a composite endpoint consisting of cardiac death, target vessel MI, or clinically driven target vessel revascularization. Further secondary clinical and angiographic endpoints will be investigated, defined in accordance with suggestions of the Academic Research Consortium (ARC). Of note, the angiographic assessment is based on clinically indicated projections only and results in no additional x-ray exposure. There is no routine angiographic follow-up. If angiographic data are available in patients who undergo symptom-driven re-catheterization, we will analyze these data to get insight into the mechanisms of potential DES restenosis. Nature and extent of the burden and risks associated with participation, benefit and group relatedness: Patients will receive the routine clinical treatment. As a consequence, the risks of this trial do not exceed the risks of any routine PCI procedure.