Clinical Trials Logo

Clinical Trial Summary

For nearly half a century, supraglottic airway devices (SGA) have been used in pediatric patients, which are more practical than face masks, facilitate oxygenation and ventilation without the need for endotracheal intubation, and less invasive than endotracheal tubes. I-Gel is a supraglottic airway management device introduced in 2007, made of a medical grade thermoplastic elastomer, designed to create a non-inflatable, anatomical seal in the pharyngeal, laryngeal and perilaryngeal structures that prevents compression trauma. Recently, the use of I-Gel has become popular in children undergoing surgery that does not require muscle relaxation. It is important to place an I-Gel in the most appropriate position in order to provide adequate ventilation and prevent complications such as mucosal injury, glottic ptosis, and gastric insufflation with potential aspiration. Successful placement is usually clinically assessed by a capnogram with endtidal carbon dioxide (ETCO2) value, visual examination and auscultation with appropriate chest elevation, absence of oropharyngeal leakage at 20 cm H2O peak inspiratory pressure. Although Fiberoptic Bronchoscope (FOB) is accepted as the preferred verification tool for direct visualization, some studies on I-Gel position using FOB reported that I-Gel placement should be repositioned in some children (12.8-49%). Ultrasonography (USG), which has recently entered the practice of upper airway examination, has become a valuable, non-invasive, simple and portable technology for evaluating airway management even in upper airway anatomy impaired by pathology or trauma. The aim of this study is to compare the use of USG with the FOB to evaluate I-Gel placement in pediatric patients. The primary endpoint is to compare the incidence of for I-Gel malposition between USG and FOB. Secondary endpoints are to find the correlation between I-Gel's USG and FOB-detected malposition and to determine the diagnostic performance of the USG.


Clinical Trial Description

The population of the study was created from the parents of pediatric patients who were scheduled for elective pediatric surgery under general anesthesia between December 2020 and February 2021 at Selcuk University Department of Anesthesiology and Reanimation. All patients were monitored with standard monitoring (ECG, non-invasive blood pressure, SpO2, ETCO2, Ppeak), after a minimum of 2 minutes of preoxygenation, mask ventilation was performed with 6-7% sevoflurane at the beginning of general anesthesia induction. Intravenous vein access was provided, and according to standard procedures; propofol 3.5 mg.kg 1, fentanyl 1 mg.kg 1 iv and remifentanil 0.1 mcg kg min 1 infusion was administered, but neuromuscular blocker was not used. The choice of the size of the I-Gel was selected according to the manufacturer's recommendations (size 1: 2-5 kg, size 1.5: 5 to 12 kg, size 2: 10 to 25 kg). Adequate anesthesia depth was confirmed by loss of eyelash reflex, symmetrical small pupils and absence of swallowing, and was guided gently along the hard palate by the 1st anesthesiologist until resistance was felt, with the I-Gel opening facing the applicator. If the patient did not tolerate the insertion of the I-Gel, an extra dose of fentanyl up to a maximum of 0.5 mcg / kg in total was administered. However, if the insertion attempt was still not tolerated, or if the capnography curve was not obtained and there was an audible leak, the technique was considered to be unsuccessful, and another SGA was then placed in the airway. If this change was not tolerated, endotracheal intubation was initiated by applying neuromuscular blocker and these were recorded. USG examination of the neck was performed by the second anesthesiologist using an 8-18 MHz linear probe Esaote Imaging was done in three planes (Transverse plane between hyoid bone and thyroid bone, Transverse plane of the lateral suprasternal notch and Parasagittal plane of pharynx and larynx) the USG score was assigned to the deployment view using a modification of the criteria proposed. The fiberoptic bronchoscope was passed through I-Gel until the glottis image was obtained.Optimal placement was defined as the end of the I-Gel behind the arytenoids, with a visible epiglottis, with or without folding to the airway, and the vocal cords are visible when the FOB is advanced under the epiglottis. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04652466
Study type Observational
Source Selcuk University
Contact Faruk Cicekci
Phone 00905057649235
Email farukcicekci@yahoo.com
Status Not yet recruiting
Phase
Start date December 15, 2020
Completion date February 15, 2021

See also
  Status Clinical Trial Phase
Recruiting NCT05642234 - Comparison of Skin - Epidural and Intervertebral Distances in Sitting and Rider Position
Recruiting NCT04527510 - Remote Breast Cancer Screening Study
Completed NCT05807737 - A Study to Assess the Accuracy of Artificial Intelligence for Ultrasound-guided Regional Anesthesia
Recruiting NCT05872906 - Using Ultrasound and Acupuncture to Explore the De-qi Location and Reaction of Specific Acupoints N/A
Recruiting NCT06068647 - Ultrasound and Respiratory Physiological Signals in Lung Diseases N/A
Completed NCT06219876 - Comparison of the Efficacy of High Intensity Laser Therapy and Low Level Laser Therapy in the Carpal Tunnel Syndrome N/A
Completed NCT05900440 - Artificial Intelligence for Learning Point-of-Care Ultrasound N/A
Completed NCT06211946 - Abdominal Aorta Palpation With Point of Care Ultrasound Imaging Measurements
Completed NCT04511143 - The Correlation Between Ultrasonography Based Muscle Architecture Parameters and Voluntary Isometric Muscle Strength
Completed NCT04316988 - Ultrasonography Versus Capnography in Detecting Endotracheal Tube Placement During Intubation in a Tertiary Hospital.
Recruiting NCT05649826 - Automated Ultrasound Cardiac Guidance Tool
Completed NCT03647618 - Anatomy Guidance for Regional Anaesthesia
Completed NCT05455346 - Eccentric Training Effects on Hamstrings Structure, Strength, and Sprint Performance N/A
Enrolling by invitation NCT04671992 - Out Of-plane Technique Against In-plane for Caudal Block N/A
Completed NCT04822116 - Continuation of Goal Directed Haemodynamic Optimization in the PACU N/A
Recruiting NCT03532165 - Use of Bedside Ultrasound in Emergency Department Patients With Concern for Pulmonary Embolism to Reduce CT Imaging N/A