Clinical Trials Logo

Clinical Trial Summary

Catheter ablation is a first-line treatment for patients with cavotricuspid isthmus (CTI) dependent atrial flutter (AFL; also known as typical AFL), a common arrhythmia. This is done using radiofrequency (RF) catheters and single-procedure success is approximately 95%. Ablation is often done using one of three methods: 1. fluoroscopically, using X-rays to guide the operator to visualise catheter position within the heart. This method involves the most radiation exposure to patient and operator. Ablation is generally performed for a set time-period (eg. 30-60secs) to ensure each ablation lesion is successful. 2. using a 3-dimensional mapping system which allows the catheters to be magnetically located and visualised on a monitor without X-rays, and using "contact force" (CF) sensing catheters. This requires minimal X-ray use, and by ensuring a minimum degree of force between catheter tip and the heart before applying RF for a set time-period (eg. 30 seconds), operators can be more confident of successful lesions. 3. using an ultra-high density mapping system which uses magnetic tracking as above, but allows higher resolution visualisation of the cardiac electrical system with potential for improving procedure success; this has not yet been formally evaluated for AFL. Catheters using this method use "local impedance" (LI) instead of CF. This is a direct measure of heart tissue impedance with real-time changes during ablation. A minimum drop or plateau in the LI value during ablation allows confidence of lesion success, without the need to ablate for a pre-defined time-period. This could potentially reduce ablation time and subsequent complications, but has also not yet been formally compared to the above for this indication. This prospective randomised study aims to compare these three standard of care procedures to determine if differences in ablation metrics, efficacy and safety exist.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT04434599
Study type Interventional
Source University of Manchester
Contact
Status Withdrawn
Phase N/A
Start date October 30, 2022
Completion date January 1, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT05777850 - High-Power Short-Duration Radiofrequency Ablation in Patients With Typical Atrial Flutter N/A
Completed NCT01401361 - Atrial Flutter Ablation With Contact Therapy Cool Path Ablation System Along With EnSite Velocity Contact System Phase 3
Completed NCT00984204 - Clinical Evaluation of Therapy™ Cool Path™ Duo Cardiac Ablation System for the Treatment of Typical Atrial Flutter (AFL) Phase 3
Withdrawn NCT01710150 - Pulmonary Vein Isolation To Reduce Future Risk Of Atrial Fibrillation In Patients Undergoing Typical Flutter N/A
Completed NCT01408485 - Therapy™ Cool Flex™ Irrigated Ablation System for Typical Atrial Flutter N/A
Completed NCT04658940 - AcQBlate Force Sensing Ablation System US IDE for Atrial Flutter (AcQForce Flutter) N/A
Recruiting NCT00750711 - Typical Flutter Ablation:A Comparison of 4 mm Versus 2 mm Irrigated cathéters N/A
Recruiting NCT03867266 - Typical Atrial Flutter, Ablation Index and Point by Point Ablation
Not yet recruiting NCT06157437 - An Exploratory Study of Focal Pulse Ablation System in the Treatment of Typical Atrial Flutter N/A
Recruiting NCT04657055 - AcQBlate Force Sensing Ablation System EU Study for Atrial Flutter (AcQForce Flutter-EU) N/A