Clinical Trials Logo

Clinical Trial Summary

Old trials aimed to evaluate Implantable Cardioverter-Defibrillator (ICD) safety and efficacy demonstrated a meaningful decreased rates of sudden death but an increased rate of hospitalization for heart failure . At the time, the chance that an endocardial lead could cause a significant tricuspid regurgitation (TR), leading to worsening heart failure, was not widely considered. Whereas, it is now well established that in patients with cardiac implantable electronic device (CIEDs), moderate or severe TR occurs frequently and it is associated with increased mortality and hospitalization for heart failure. The present study aims to report the long-term results of tricuspid valve repair and replacement surgery in patients with CIEDs Indeed, patients with TR and CIEDs can be divided in 2 categories: CIEDs induced TR and CIEDs associated TR. In patients with CIEDs induced TR, the valve dysfunction is directly caused by the lead with several mechanism such as mechanical interference with tricuspid valve (TV) leaflet mobility and coaptation (impingement), valve damage during lead placement or manipulation and sub-valvular entanglement. In patients with CIEDs associated TR the valve dysfunction is not directly caused by the lead. In 2009 approximately 720 000 CIEDs were implanted worldwide [7] and since then a continuous increase of CIEDs implantation was registered, with an estimation of 1.4 millions of CIEDs implantation in 2023. With this impressive number of CIEDs requirement, the need for surgical or trans-catheter treatment of severe TR CIEDs induced or associated, increased steadily in the past years and it likely will continue to increase in the next years. However, limited data are available regarding the outcome of tricuspid valve surgery in patients with CIEDs, particularly for the long-term results. With this study we aim to report the long-term result of tricuspid valve repair and replacement in patients with CIEDs.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT05774821
Study type Observational
Source Ospedale San Raffaele
Contact
Status Completed
Phase
Start date February 4, 2022
Completion date February 27, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT05434507 - Feasibility Study of Treating Tricuspid Regurgitation With K-ClipTM Transcatheter Annuloplasty System N/A
Completed NCT03144024 - Comparison of Rigid Annuloplasty Ring With a Band in the Correction of Secondary Tricuspid Insufficiency N/A
Enrolling by invitation NCT05825898 - Outcome of Patients With Severe Functional TR According to Medical, Transcatheter or Surgical Treatment
Completed NCT05836493 - Very Long-term (>15 Years) Results of Tricuspid Valve Repair.
Enrolling by invitation NCT06033274 - Global Multicenter Registry on Transcatheter TRIcuspid Valve RePLACEment
Recruiting NCT05671640 - Feasibility Study of the DragonFly-T System for Severe Tricuspid Regurgitation N/A
Recruiting NCT06027307 - Enavogliflozin Outcome Trial in Functional Tricuspid Regurgitation Phase 3
Terminated NCT04665583 - Prehab Prior to Undergoing Tricuspid Intervention
Recruiting NCT06307262 - European Registry of Transcatheter Repair for Tricuspid Regurgitation
Completed NCT02981953 - TRI-REPAIR: TrIcuspid Regurgitation RePAIr With CaRdioband Transcatheter System N/A
Recruiting NCT04433065 - TTVR Early Feasibility Study N/A
Not yet recruiting NCT05556460 - Safety and Effectiveness Study of DragonFly-T System for Severe Tricuspid Regurgitation N/A
Recruiting NCT05667519 - Prevention of Pacemaker Lead Induced Tricuspid regurgitAtion by Transesophageal eCho guidEd Implantation (PLACE) N/A
Recruiting NCT04653428 - German Registry for Transcatheter Tricuspid Valve Interventions
Recruiting NCT05179616 - Pforzheim Tricuspid Valve Registry - Outcomes of Percutaneous Tricuspid Valve Repair
Completed NCT02644616 - The Safety and Efficacy of Tolvaptan for Patients With Tricuspid Regurgitation and Right Heart Failure After Left Heart Valves Replacement Phase 4
Recruiting NCT05328284 - PASCAL for Tricuspid Regurgitation - a European Registry
Completed NCT02675244 - Evaluating the Benefit of Concurrent Tricuspid Valve Repair During Mitral Surgery N/A
Recruiting NCT05436028 - A Study to Evaluate the Safety and Performance of LuX-Valve Plus System for Tricuspid Replacement N/A
Completed NCT01093001 - Tricuspid Regurgitation Study Phase 4