Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT05770648
Other study ID # CSP-K-02
Secondary ID
Status Not yet recruiting
Phase N/A
First received
Last updated
Start date March 2023
Est. completion date December 2024

Study information

Verified date March 2023
Source Shanghai Huihe Medical Technology Co., Ltd
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

To evaluate the efficacy and safety of the transcatheter tricuspid valve ring system produced by Shanghai Huihe Medical Technology Co., Ltd. in the treatment of patients with severe or above tricuspid regurgitation who cannot be evaluated by clinicians for surgery.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 64
Est. completion date December 2024
Est. primary completion date December 2023
Accepts healthy volunteers No
Gender All
Age group 60 Years and older
Eligibility Inclusion Criteria: 1. Age =60, male or female; (2) Patients with severe or above secondary tricuspid regurgitation (TR=4+) (secondary tricuspid regurgitation: tricuspid regurgitation caused by right atrial disease, right ventricular cardiomyopathy, right ventricular myocardial infarction, left heart valve disease, congenital heart disease and other diseases); (3) A multidisciplinary cardiac team consisting of cardiovascular physicians, cardiovascular surgeons, imaging physicians, anesthesiologists, and at least 2 physicians considered the subjects to be at high risk for surgical procedures, i.e., EuroScore II was greater than 3.0%; (4) Left ventricular ejection fraction LVEF=30%; (5) The subject voluntarily participates in the clinical trial and agrees or his guardian agrees to sign the informed consent; (6) Symptoms of tricuspid regurgitation, such as chest tightness, asthma, shortness of breath, lower limb edema, ascites; (7) NYHA Grades 2 to 4, including Grades 2 and 4; (8) The optimal drug treatment for tricuspid valve = 30 days and the patient's state was stable; (9) Patients with mitral regurgitation, atrial fibrillation, coronary artery disease, and heart failure should be treated for = 30 days with medication or = 30 days after instrument therapy and in stable condition. Exclusion Criteria: 1. Patients with pure organic (i.e. primary) tricuspid regurgitation; 2. Patients with pulmonary artery systolic blood pressure =60 mmHg; 3. Patients with tricuspid valve prosthesis or plastic ring, or patients with tricuspid valve-related surgery; 4. Patients with retrotricuspid annulus calcification; 5. Evidence of intracardiac, jugular and superior vena cava masses, thrombus or growths; 6. Patients with more than moderate aortic stenosis, mitral stenosis, aortic regurgitation, or mitral regurgitation; 7. Patients with severe uncontrolled hypertension (systolic blood pressure =180 mmHg and/or diastolic blood pressure =110 mmHg); 8. Percutaneous coronary intervention within 1 month; 9. Myocardial infarction or known unstable angina within the previous 1 month; 10. cerebrovascular accidents occurred within the previous 3 months; 11. Patients with active endocarditis or active rheumatic heart disease; 12. Patients with coagulopathy, hypercoagulability or anemia (hemoglobin < 90 g/L); 13. Patients in the acute infection stage or other severe infections; 14. Patients with active peptic ulcer or active gastrointestinal bleeding; 15. severe end-stage diseases (such as malignant tumors, severe lung diseases, liver diseases, renal failure) with a life expectancy of less than 1 year; 16. Patients with known allergy or contraindications to the raw material or drug (e.g. antiplatelet drugs, anticoagulants) of the test product; 17. persons addicted to alcohol, drugs or drugs; 18. Patients with cognitive impairment; 19. A history of epilepsy or mental illness with primary and persistent seizures and poor drug control; 20. Participate in any other clinical trial (other than a registered study) within 30 days prior to signing the informed consent; 21. have had a pacemaker (other than a leadless pacemaker) or a defibrillator implanted in the past, or plan to have a pacemaker (other than a leadless pacemaker) or a defibrillator implanted; 22. tricuspid stenosis; 23. Ebstain syndrome; 24. esophageal esophageal echocardiography (TEE) and Trans thoracic echocardiography (TTE) were not esophageal esophageal tricuspid ring anatomy; 25. Hemodynamic instability; 26. Patients with chronic dialysis; 27. Women who have planned to become pregnant during pregnancy, lactation or clinical study; 28. Other conditions for which the investigator considers it inappropriate to participate in the clinical trial.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Transcatheter Annuloplasty
Under the guidance of ultrasound, the transcatheter tricuspid ring forming system accurately reaches the designated position of the tricuspid valve region through the jugular vein and superior vena cava approach. The expanded tricuspid ring tissue is clammed together with the clamping parts and anchor parts, and the circumference of the tricuspid ring is reduced, thus reducing the area of the opening of the tricuspid valve that cannot be closed originally, and achieving the purpose of minimally invasive treatment of tricuspid regurgitation.
Other:
The guidelines guide medication
The guidelines guide medication

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Shanghai Huihe Medical Technology Co., Ltd

Outcome

Type Measure Description Time frame Safety issue
Primary The percentage of subjects with no all-cause death, no heart failure readmitted, NYHA increased by one grade or more, and TR decreased =1+ within 6 months after randomization. The percentage of subjects with no all-cause death, no heart failure readmitted, NYHA increased by one grade or more, and TR decreased =1+ within 6 months after randomization. Within 6 months of randomization
See also
  Status Clinical Trial Phase
Recruiting NCT05434507 - Feasibility Study of Treating Tricuspid Regurgitation With K-ClipTM Transcatheter Annuloplasty System N/A
Completed NCT03144024 - Comparison of Rigid Annuloplasty Ring With a Band in the Correction of Secondary Tricuspid Insufficiency N/A
Enrolling by invitation NCT05825898 - Outcome of Patients With Severe Functional TR According to Medical, Transcatheter or Surgical Treatment
Completed NCT05836493 - Very Long-term (>15 Years) Results of Tricuspid Valve Repair.
Enrolling by invitation NCT06033274 - Global Multicenter Registry on Transcatheter TRIcuspid Valve RePLACEment
Recruiting NCT05671640 - Feasibility Study of the DragonFly-T System for Severe Tricuspid Regurgitation N/A
Recruiting NCT06027307 - Enavogliflozin Outcome Trial in Functional Tricuspid Regurgitation Phase 3
Terminated NCT04665583 - Prehab Prior to Undergoing Tricuspid Intervention
Recruiting NCT06307262 - European Registry of Transcatheter Repair for Tricuspid Regurgitation
Completed NCT02981953 - TRI-REPAIR: TrIcuspid Regurgitation RePAIr With CaRdioband Transcatheter System N/A
Recruiting NCT04433065 - TTVR Early Feasibility Study N/A
Not yet recruiting NCT05556460 - Safety and Effectiveness Study of DragonFly-T System for Severe Tricuspid Regurgitation N/A
Recruiting NCT05667519 - Prevention of Pacemaker Lead Induced Tricuspid regurgitAtion by Transesophageal eCho guidEd Implantation (PLACE) N/A
Recruiting NCT04653428 - German Registry for Transcatheter Tricuspid Valve Interventions
Recruiting NCT05179616 - Pforzheim Tricuspid Valve Registry - Outcomes of Percutaneous Tricuspid Valve Repair
Completed NCT02644616 - The Safety and Efficacy of Tolvaptan for Patients With Tricuspid Regurgitation and Right Heart Failure After Left Heart Valves Replacement Phase 4
Recruiting NCT05328284 - PASCAL for Tricuspid Regurgitation - a European Registry
Not yet recruiting NCT05848284 - Clinical Safety and Efficacy of the VDyne Transcatheter Tricuspid Valve Replacement System for the Treatment of Tricuspid Regurgitation ( VISTA-US) Phase 1
Active, not recruiting NCT02675244 - Evaluating the Benefit of Concurrent Tricuspid Valve Repair During Mitral Surgery N/A
Recruiting NCT05436028 - A Study to Evaluate the Safety and Performance of LuX-Valve Plus System for Tricuspid Replacement N/A