Clinical Trials Logo

Clinical Trial Summary

Total knee arthroplasty (TKA) is still considered the treatment of choice for painful osteoarthritis. In the last decades neutral mechanical knee alignment in the coronal plane has been considered the gold standard. However, the optimal TKA alignment is still debated. Today, component rotation measurements on three-dimensional (3D) reconstructed computed tomography (CT) images are considered the gold standard for assessing native preoperative alignment and TKA component position. In this study pre-and postoperative radiographic measurements, functional scores, and biomechanical parameters of patients with knee osteoarthritis will be assessed with the aim to investigate the relationship between deviations of TKA alignment from native preoperative alignment and clinical, functional and biomechanical alignment.


Clinical Trial Description

Total knee arthroplasty (TKA) is still considered the treatment of choice for painful osteoarthritis resulting in pain and functional improvement. Despite the development of novel prosthetic design and improved outcome, about 20% of patients report persisting pain interfering with their daily activities.Total knee prostheses are aligned in the coronal, sagittal and axial planes during implantation. In the last decades, neutral mechanical knee alignment in the coronal plane has been considered the gold standard. The aim of mechanical alignment in TKA is to achieve a femorotibial joint line that is perpendicular to the mechanical axis of the long leg axis hence correcting any varus-valgus deformity via prosthesis placement with the goal of equally distributing the load between the medial and lateral prosthesis component. However, the optimal TKA alignment is still debated. Traditionally, knee alignment and total knee arthroplasty component position have been assessed using radiographs. However, this method has a low accuracy and reliability because of variation in limb rotation, knee extension deficit, patient positioning, or magnification factors. Component rotation measurements on three-dimensional (3D) reconstructed computed tomography (CT) images have replaced former methods and are now considered the gold standard for assessing native preoperative alignment and TKA component position. In this study pre-and postoperative radiographic measurements, functional scores, and biomechanical parameters of patients with knee osteoarthritis will be assessed with the aim to investigate the relationship between deviations of TKA alignment from native preoperative alignment and clinical, functional and biomechanical alignment. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05435092
Study type Observational
Source University Hospital, Basel, Switzerland
Contact Yves Acklin, PD Dr. med.
Phone +41 61 315 27 71
Email yves.acklin@usb.ch
Status Recruiting
Phase
Start date April 1, 2022
Completion date May 1, 2026

See also
  Status Clinical Trial Phase
Terminated NCT04597684 - Cemented vs. Cementless TKA N/A
Completed NCT02314832 - Risk of Falling After CFNB Versus ACB N/A
Completed NCT03671954 - Total Knee Arthroplasty Biomechanics N/A
Completed NCT02453321 - Continuous Adductor Canal Blocks Vs. Low Dose Femoral Nerve Blocks For Early Rehabilitation After Total Knee Arthroplasty Phase 4
Not yet recruiting NCT05310474 - Does an Active Range of Motion Monitor Improve Outcomes/Decrease Cost for Patients Undergoing Total Knee Arthroplasty? N/A
Completed NCT04020471 - How Variations in Pharmacogenomic Profiles Affect Pain and Narcotic Needs Following Total Knee Arthroplasty (TKA)