Total Hip Replacement Clinical Trial
Official title:
Biofilm Investigation on Ceramic, Metal and Polyethylene Bearing Components From Explanted Hip Joint Prosthesis
In this study the investigators sonicate the bearing components of the explanted hip prosthesis which allows highly sensitive detection of in vivo biofilms (qualitatively and quantitatively). The hip prosthesis bearing components are composed from different material. The purpose of this study is to analyse the resistance against biofilm adhesion of ceramic, metal and polyethylene prosthesis components through microbiologic analysis of sonicates.
Status | Recruiting |
Enrollment | 200 |
Est. completion date | March 2017 |
Est. primary completion date | December 2016 |
Accepts healthy volunteers | No |
Gender | Both |
Age group | 18 Years and older |
Eligibility |
Inclusion Criteria: - Subject must be aged 18 or more. - Subject must be scheduled to undergo an explanation of the hip endoprosthesis during the 1- or 2- stage revision procedure because of the septic or mechanical indication. - Subject must personally sign and date the informed consent document indicating that the subject has been informed of all pertinent aspects of the study. Exclusion Criteria: - Patient not scheduled for the index Operation procedure with removal of hip endoprosthesis |
Observational Model: Cohort, Time Perspective: Prospective
Country | Name | City | State |
---|---|---|---|
Germany | Charité Universitätsmedizin Berlin | Berlin |
Lead Sponsor | Collaborator |
---|---|
Charite University, Berlin, Germany | Ceram Tec GmbH, Pro-Implant Foundation |
Germany,
Achermann Y, Vogt M, Leunig M, Wüst J, Trampuz A. Improved diagnosis of periprosthetic joint infection by multiplex PCR of sonication fluid from removed implants. J Clin Microbiol. 2010 Apr;48(4):1208-14. doi: 10.1128/JCM.00006-10. Epub 2010 Feb 17. — View Citation
Banche G, Allizond V, Bracco P, Bistolfi A, Boffano M, Cimino A, Brach del Prever EM, Cuffini AM. Interplay between surface properties of standard, vitamin E blended and oxidised ultra high molecular weight polyethylene used in total joint replacement and adhesion of Staphylococcus aureus and Escherichia coli. Bone Joint J. 2014 Apr;96-B(4):497-501. doi: 10.1302/0301-620X.96B4/32895. — View Citation
Gómez-Barrena E, Esteban J, Medel F, Molina-Manso D, Ortiz-Pérez A, Cordero-Ampuero J, Puértolas JA. Bacterial adherence to separated modular components in joint prosthesis: a clinical study. J Orthop Res. 2012 Oct;30(10):1634-9. doi: 10.1002/jor.22114. Epub 2012 Mar 30. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Qualitative analysis of sonication fluid after sonication of explanted bearing components of the hip endoprosthesis during a revision surgery | Qualitative Analysis, i.e. frequency of positive sonication fluid cultures (No. positive/No. all cultures) deriving from 3 different biomaterials (namely: Ceramic, Cobalt-chrome-metal, and Polyethylene), the number of variables which will be evaluated following: bearing component and its material (Ceramic, Cobalt-chrome-metal, and Polyethylene). All three material types will be compared between each other regard to microbiology analysis of sonication fluid of bearing components. |
Prospective: patient recruitment up to 2 years | No |
Primary | Quantitative Analysis e.g. No. of microorganisms in sonication fluid (CFU/ml) deriving from 3 different biomaterials (namely: Ceramic, Cobalt-chrome-metal, and Polyethylene). | Prospective: patient recruitment up to 2 years | No | |
Secondary | Amount of patients with septic loosening of hip joint | Prospective: patient recruitment up to 2 years | No |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04774562 -
The Effect of Video-Assisted Discharge Education After Total Hip Replacement Surgery
|
N/A | |
Recruiting |
NCT02793934 -
The Pilot Project Development Of MEdical Rehabilitation System in Russian Federation
|
||
Completed |
NCT02554149 -
Radiological Measurement of Femoral Stem Version Using Lateral Decubitus Method: A Prospective Study
|
N/A | |
Completed |
NCT01228162 -
Influence of Muscle Relaxation With Rocuronium Bromide During General Anaesthesia on Muscle Trauma and Postoperative Analgetic Consumption in Patients With Total Hip Prosthesis Implantation
|
Phase 4 | |
Completed |
NCT00219921 -
Postoperative Analgesia After Total Hip Replacement
|
Phase 3 | |
Completed |
NCT02644096 -
Rehabilitation of Patients After THR - Based on Patients´Selfrated Health
|
Phase 1 | |
Completed |
NCT02720471 -
Local Analgesia Versus Local Peroperative Infiltration After Total Hip Replacement
|
Phase 3 | |
Completed |
NCT03218267 -
The Postural Control in Patients After Total Hip Replacement
|
N/A | |
Recruiting |
NCT03120312 -
Short Term and Long Term Outcome for Elderly Patients Treated With Total Hip Replacement
|
||
Withdrawn |
NCT01523418 -
Study to Observe Safety of Xarelto in VTE Prophlylaxis After Elective TKR (Total Knee Replacement) or THR (Total Hip Replacement)
|
N/A | |
Recruiting |
NCT01782859 -
Effect of Steroids on Thrombosis (Blood Clot Formation) and Inflammation in Patients Undergoing Hip Surgery
|
N/A | |
Completed |
NCT00889148 -
Morphine COnsumption in Joint Replacement Patients, With and Without GaBapentin Treatment, a RandomIzed ControlLEd Study
|
N/A | |
Completed |
NCT05375565 -
Comparative Effects of Weight Bearing and Non-weight Bearing Exercises in Patients With Total Hip Replacement
|
N/A | |
Completed |
NCT04166539 -
Neurotoxicity and Cardiotoxicity in Total Joint Arthroplasty
|
||
Completed |
NCT03072706 -
Evaluation of X-ray, Acetabular Guides and CT in THR
|
N/A | |
Not yet recruiting |
NCT02272205 -
Evaluation of Conventional Antibiotic Prophylaxis During a Change of Hip or Knee Infected at a Time
|
N/A | |
Completed |
NCT01522014 -
Randomized Clinical Trial of Ceramic Bearing Primary Total Hip Arthroplasty
|
Phase 4 | |
Completed |
NCT06169878 -
Efficiency of the Adjustable Lower Extremity Abduction Apparatus After Total Hip Replacement Surgery
|
N/A | |
Not yet recruiting |
NCT06409312 -
Digital Healthcare App After Total Hip Arthroplasty
|
N/A | |
Recruiting |
NCT03240484 -
Examining Effects of Spinal Fusion on Outcomes Following Total Hip Replacement
|