Clinical Trials Logo

Clinical Trial Summary

Cementless fixation, with or without screw augmentation, has evolved during the past few decades as the preferred method for acetabular reconstruction. Although major improvements have been recorded with regard to clinical outcomes and survivorship, acetabular component loosening remains among the most common causes of failure and revision. Patient age, poor bone quality and conditions, such as osteonecrosis and dysplasia, have been observed to influence negatively long-term clinical results. Initial stability is fundamental for survivorship of cementless cups. Prerequisites to achieve durable cementless cup fixation are close contact with viable native bone, primary mechanical stability and secondary bone integration. Press-fit techniques provide optimal conditions for bone ingrowth and fixation but research focused on cup material in order to improve primary stability. Pore size, bone-implant apposition, and material properties all influence bone ingrowth and long-term stability. Biological ingrowth surfaces have become a standard prosthetic element in reconstructive hip surgery. A material's properties, three-dimensional architecture, and surface texture all play integral parts in its biological performance. Trabecular metal is an important new biomaterial that has been introduced to enhance the potential of biological ingrowth as well as provide a structural scaffold in cases of severe bone deficit. The continuity between the porous and solid parts has been specifically developed to overcome the limitations of the traditional porous coatings. In fact, the absence of an interface between the trabecular structure and the bulk material provides greater structural solidity and thus higher resistance to detachment and corrosion. Initial clinical applications have focused on bone restoration in tumor and salvage cases and in primary and revision reconstructive cases where the increased biological fixation would be of clinical benefit. However the bone ingrowth potential and mechanical integrity of this material offer exciting options for orthopedic reconstructive surgeons such as difficult THA cases, such as patients with high demands, subjects affected by severe hip conditions (i.e. osteonecrosis, dysplasia) or with extremely poor bone quality. Medacta Mpact 3D Metal cup, is an acetabular cup realized using the EBM (Electron Beam Melting) powder technology; this production method offers a high friction and scratch-fit feel for the initial stability, without the need of any additional coating. Moreover the 3D Metal structure creates a favorable environment for bone thus providing secondary fixation. The aim of this study is to evaluate the long term clinical and radiological performance of MPact 3D Metal acetabular component.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT04801680
Study type Observational
Source Medacta International SA
Contact Luigi Zagra, Dr
Phone 00390266214834
Email luigi.zagra@fastwebnet.it
Status Recruiting
Phase
Start date November 7, 2019
Completion date December 7, 2032

See also
  Status Clinical Trial Phase
Terminated NCT02818894 - Spinal Anesthesia in Total Hip Arthroplasty Phase 4
Completed NCT02242201 - Total Hip Arthroplasty (THA) Lumbar Plexus Verses Periarticular Phase 4
Active, not recruiting NCT02414542 - Minima Clinical Study
Completed NCT01817010 - Strength and Function Following Total Hip Arthroplasty N/A
Completed NCT01443975 - Clinical Evaluation on the Use of the X-pander Device N/A
Recruiting NCT05530174 - Effect of Single vs Multiple Prophylactic Antibiotic Doses on PJI Following Primary THA in Patients With a Fracture N/A
Recruiting NCT05530551 - Effect of Single vs Multiple Prophylactic Antibiotic Doses on PJI Following Primary THA in Patients With OA N/A
Recruiting NCT05054192 - Reliability and Validity of Modified Four Square Step Test
Recruiting NCT06141928 - Comparison of Three Different Surgical Approaches on the Functional Outcome After Total Hip Arthroplasty N/A
Recruiting NCT04492462 - The Impact of Two Different Physical Therapy Programs in the Rehabilitation of Patients Undergoing Anterior Approach Hip Replacement Surgery N/A
Withdrawn NCT02926651 - Single Versus Multi-Dose Oral Tranexamic Acid in Patients at High Risk for Blood Transfusion After Total Joint Arthroplasty Phase 4
Completed NCT02308813 - Predictability of the Ability to Perform an Emergency Stop With Disorders of the Hip N/A
Recruiting NCT02032017 - Percutaneous Assisted Approach for Total Hip Replacement and it's Effect on Functional Rehabilitation. N/A
Recruiting NCT01312077 - The Analgesic Efficacy of Periarticular Infiltration of Local Anaesthetic for Total Hip Replacement Phase 4
Withdrawn NCT01380665 - Prevena™ Incision Management System Over Primarily Closed Hip and Knee Incisions in Patients Immediately Post Total Hip and Knee Arthroplasty Phase 4
Recruiting NCT05893563 - Corail Stability at 5-Years Post-Total Hip Arthroplasty
Recruiting NCT06088069 - Effect of Virtual Reality on Perioperative Anxiety, Stress and Pain in Total Hip Arthroplasty N/A
Active, not recruiting NCT03210844 - The Clinical Outcomes After Direct Anterior Approach and Microposterior Approach for Total Hip Arthroplasty N/A
Terminated NCT02006251 - Real-Time Instrument for Acetabular Shell Positioning
Completed NCT01525667 - Safety and Efficacy of IM Injections of PLX-PAD for the Regeneration of Injured Gluteal Musculature After Total Hip Arthroplasty Phase 1/Phase 2