Study title: The Efficacy and Safety of tooth bleaching procedure using Y10 Whitening toothpaste and RF current

The Device: The Brighttonix Y10 Tooth Whitening system is indicated for use in painless non-invasive tooth whitening treatments.

Design: Single center, randomized, controlled, double blind, two-arm, prospective clinical study.

Follow up visits at 7 days (phone visit), 12 weeks and 26 weeks.


Clinical Trial Description

Purpose: To assess the efficacy and the safety of tooth bleaching procedure using Y10 Whitening toothpaste and RF current (Y10 Device), versus placebo (no RF current and off- the -shelf non bleaching toothpaste) in healthy patients seeking tooth bleaching.

No. of Subjects/Sites: A total of 60 patients at Hadassah Medical Center will be randomized, 30 patients for the test arm, and 30 patients for the placebo arm.

A 40% to 60% male (or female) ratio will be maintained.

Target teeth: At least 4 teeth between teeth 13-23 (Upper front teeth) according to the international teeth numbering system.

Upper and lower teeth will be treated with the same treatment arm as described.

Endpoints:

Primary endpoint:

• At the end of the treatment (V3), compared to prior of treatment, the mean shade change will be at least two shades (Vita Bleachguide 3D Master, Vita P/N: B361) as measured at the middle one-third area of the labial surface of the selected target teeth.

Secondary endpoints:

- Compared to prior of treatment, the mean shade change at 3 and 6 months will be at least one shade (Vita Bleachguide 3D Master, Vita P/N: B361) as measured at the middle one-third area of the labial surface of the selected target teeth.

- Compared to prior of treatment, color change evaluates with a spectrophotometer (VITA Easyshade Advance 4; VITA Zahnfabrik, Bad Sackingen, Germany), before and after treatment, at 3 and 6 months will be at least one shade. (Device with a high reliability, over 96%, Kim-Pusateri Et al. Reliability and accuracy of four dental shade-matching devices. Journal of Prosthetic Dentistry United States 2009;101(March (3)):193-9.)

- Compared to prior of treatment, the mean shade change for the lower teeth numbers 43-33 after treatment, 3 and 6 months will be at least one shade.

- Lesion in the gingiva of the upper and lower teeth (+/- in each of the teeth numbers 33-43, 13-23 after treatment and 3 months.

- Compared to prior of treatment - teeth sensitivity to cold and touch stimulation - target teeth - VAS scale after treatment, 3 and 6 months. For the VAS, the participants will place a line perpendicular to a 10-mm-long line with zero at one end indicating ''no TS'' and the other end indicating ''unbearable TS.''

- Patient oral questionnaire - post treatment, 7 days, 3 months, 6 months (See below).

- Patient Reported Outcomes: (Scale 0-4). OHIP14—aesthetics questions for patients that received dental bleaching - (see below) - before treatment and in 3 months.

- Periodontal parameters at baseline, 3 and 6 months: plaque index, sulcular bleeding index, pocket depth - all at the target teeth. (See below details).

Inclusion criteria:

1. Signed and dated Informed Consent Form.

2. Normal and controlled general health.

3. Male or female patients aged between 18-60 years old.

4. Availability for the 37 weeks duration of the study.

5. The patient has at least 4 natural teeth with no buccal restoration in the upper front area of the jaw (teeth 13-23), at least 2 of them with VITA shade >15, in accordance with VITA Bleachedguide 3D-MASTER (P/N: B361, VITA Zahnfabrik H Rauter GmbH & Co. KG, D-79713 Bad Sackingen, Germany).

6. Females of childbearing potential must be non-pregnant or non-lactating during the course of the study

Exclusion criteria:

1. Underwent a teeth bleaching procedure in the last 3 years.

2. Pockets of >5 mm with BOP in the target area.

3. Heavy smokers - > 10 cigarettes per day.

4. Tetracycline staining of target teeth.

5. Presence of oral local mechanical factors that could (in the opinion of the Investigator) influence the outcome of the study.

6. Presence of dental restorations in more than 2 teeth in the target area.

7. Uncontrolled periodontitis or sever gingival inflammation

8. Scheduled or simultaneous periodontal treatment.

9. Presence of orthodontic appliances, or any removable appliances.

10. Presence of soft or hard tissue tumours of the oral cavity.

11. Presence of any of the following oral conditions: major recurrent aphthous ulcers, stomatitis, abscesses and related oral pathologies.

12. The presence of any medical or psychiatric condition or any other condition that, in the opinion of the Investigator, could affect the successful participation of the patient in the study.

13. Subject participates in any other clinical study 30 days prior to the start of the study and throughout the study duration.

14. Implanted pacemaker or internal defibrillator, or any other active electrical implant anywhere in the body

15. Medical conditions of bleeding disorders, leukaemia, cirrhosis, vascular disease, sarcoidosis, active hepatitis, HIV. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02841514
Study type Interventional
Source Brighttonix Medical Ltd.
Contact
Status Withdrawn
Phase N/A
Start date September 2016

See also
  Status Clinical Trial Phase
Recruiting NCT03588871 - Comparison of the Efficacy and Quality of Life of Three Bleaching Products Phase 4
Completed NCT05725850 - The Effect of an Experimental Gel Based on Acmella Oleracea Extract in Reducing Post-bleaching Tooth Sensitivity N/A
Completed NCT02942082 - Clinical Evaluation for Post Bleaching Hypersensitivity Using Desensitizing Agent During In-office Bleaching N/A
Completed NCT04238429 - Whitening Efficacy of Dentifrice Containing 10% High Cleaning Silica, 0.5% Sodium Phytate and 0.5% Sodium Pyrophosphate N/A
Completed NCT02463552 - Naproxen on Tooth Sensitivity Caused by In-office Bleaching N/A
Recruiting NCT05202093 - Eight Week Clinical Study to Investigate Reduction of Extrinsic Tooth Stain by Electric Toothbrush N/A
Recruiting NCT04013659 - Effect of Gel Renewal During In-office Dental Bleaching Phase 1
Completed NCT02353611 - Safety and Efficacy of a 6% Hydrogen Peroxide Tooth Bleaching Agent N/A
Completed NCT03207204 - In-office Bleaching Using a Violet Light N/A
Completed NCT05021965 - The Effectiveness of At-home , In-office and Combined Dental Bleaching System :A Randomized Controlled Clinical Trial N/A
Completed NCT03514290 - Effect of Low-level Laser Therapy on Post-bleaching Sensitivity and Color Change N/A
Completed NCT04855279 - Prevention of Bleaching Induced Sensitivity N/A
Not yet recruiting NCT06180707 - Pregabalin Gel in Reducing Post-operative Tooth Sensitivity Surgery Caused by Bleaching With 35% Hydrogen Peroxide Phase 3
Completed NCT03039270 - Evaluation of Sensitivity With and Without Sonic Activation of a Desensitizing Gel Before in Office Bleaching in Adults N/A
Completed NCT03089216 - Combined Bleaching Technique: Efficacy and Tooth Sensitivity Phase 4