Respiratory Rate Clinical Trial
Official title:
Respiratory Monitoring System Safety and Performance Study
The goal of this observational study is collect data to evaluate the efficacy of the RMS system in monitoring, recording, and presenting respiratory function data to the user in participants scheduled for pulmonary function testing (PFT). Participants will complete: - 60 episodes of data collection with a decreased tidal volume - 30 episodes of data collection with an increased tidal volume - 80 episodes with normal tidal volume breathing The TSS will continuously transmit sound data to an adjacent personal computer (PC) via Bluetooth Low-Energy (BLE). TSS trachea sound data will be recorded on the PC and then transmitted via a secure wireless network to an RTM cloud account that is HIPPA compliant. Reference breathing data will be simultaneously recorded using an FDA approved hospital ventilator (Hamilton Medical, HAMILTON-C1) with a calibrated pneumotach, capnometer, and a tight-fitting face mask. This system accurately measures and records a spontaneously breathing patient's RR, TV, MV, and end-tidal carbon dioxide concentration.
Observational single-center data will be captured on up to 50 patients scheduled for pulmonary function testing (PFT) at Thomas Jefferson University Hospital's (TJUH) outpatient PFT facility. Plan is to record a complete data set from 30 patients. Breathing data for this study will be collected in the PFT facility by research personnel approximately 1 hour before or after the scheduled PFT test. Study personnel will adhere the TSS to the skin over the proximal trachea (midline above the sternal notch). The patient's neck will be examined prior to TSS attachment. The TSS will continuously transmit sound data to an adjacent personal computer (PC) via Bluetooth Low-Energy (BLE). TSS trachea sound data will be recorded on the PC and then transmitted via a secure TJUH wireless network to an RTM cloud account that is HIPPA compliant. Reference breathing data will be simultaneously recorded using an FDA approved hospital ventilator (Hamilton Medical, HAMILTON-C1) with a calibrated pneumotach, capnometer, and a tight-fitting face mask. This FDA approved system accurately measures and records a spontaneously breathing patient's RR, TV, MV, and end-tidal carbon dioxide concentration. Study subjects will breathe through the HAMILTON ventilator's face mask, , capnometer, and pneumotach over a range of RR, TV, and MV with the data recorded on a computer. Each study subject will breathe with a normal RR, TV, and MV for approximately 5 minutes. Each subject will then breathe with a normal RR and a decreased tidal volume for approximately 60 to 80 seconds episode (shallow breathing), followed by a rest period (normal breathing). Each subject will then breathe with a normal RR and an increased tidal volume for approximately 60 to 80 seconds episode (deep breathing), followed by a rest period (normal breathing). This series of breathing will take approximately 7.5 minutes to record. Each subject will complete a second series of breathing using the identical methods. Study subjects will observe a computer screen that displays breath- by-breath tidal volume to help them maintain their tidal volume in the desired range during each recording. Plan is to record and analyze approximately 280 breaths per study subject and 8,400 breaths from the 30 study subjects. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03832205 -
Validation of Respiratory Rate and Heart Rate Measurements by Capaciflectors Placed in Four Locations on the Chest
|
||
Completed |
NCT04506684 -
Reveal LINQ Respiration Clinical Study
|
||
Completed |
NCT03685227 -
A Closer Look at Yoga Nidra: Sleep Lab Analyses
|
N/A | |
Completed |
NCT04179279 -
Comparative Analysis of a Non-contact Respiratory and Heart Rate Monitor Vs. a Conventional Clinically Validated Reference Monitor
|
||
Completed |
NCT04077593 -
On the PhonE Respiratory rAte Study (OPERA)
|
||
Completed |
NCT03750344 -
ChroniSense Polso Wrist Worn Respiration Rate Validation Study
|
N/A | |
Completed |
NCT05366049 -
The Effect of Methods Used in Oral Antipyretic Administration on the Vital Findings of the Child With Fever
|
N/A | |
Completed |
NCT03148873 -
RespiraSense Versus Capnography & Manual Counting
|
||
Recruiting |
NCT05263791 -
Evaluation the Non-Inferiority of Airmod to Capnostream™35
|
N/A | |
Completed |
NCT05246358 -
Respiratory Rate Validation Study - ChroniSense Polso
|
N/A | |
Not yet recruiting |
NCT06292299 -
The PARS Study: Paediatric Advanced Respiratory Service Study - An Observational Diagnostic Feasibility Study
|
||
Recruiting |
NCT05022264 -
Remote Investigation and Assessment of Vital Signs
|
||
Completed |
NCT06086769 -
High Flow Oxygen Therapy Effect on Healthy Subjects
|
N/A | |
Completed |
NCT04104737 -
Spire Medical Health Tag Respiratory Rate Validation in Adults
|
N/A | |
Completed |
NCT04064645 -
Bora Band Respiration Rate Study
|
N/A | |
Completed |
NCT01472133 -
Validation of Respiration Rate Algorithms
|
N/A | |
Completed |
NCT03306537 -
Sensor Validation Study - Quality Assurance
|
||
Active, not recruiting |
NCT03750318 -
Validation Study on RENEW's Aingeal at KK Women's and Children's Hospital
|
N/A | |
Completed |
NCT03754231 -
Validation Study on RENEW's Aingeal at KK Women's and Children's Hospital
|
N/A | |
Completed |
NCT04346498 -
Can Kangarooing Small Babies on the Back of a Mother Keep Them Warm and Stable
|
N/A |