Clinical Trials Logo

Clinical Trial Details — Status: Terminated

Administrative data

NCT number NCT03637374
Other study ID # IRB00075706
Secondary ID
Status Terminated
Phase N/A
First received
Last updated
Start date September 8, 2020
Est. completion date June 6, 2022

Study information

Verified date July 2022
Source Johns Hopkins University
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The primary purpose of this study is to assess the use of the TAAA Debranching Stent Graft System to repair thoracoabdominal aortic aneurysms in patients having appropriate anatomy, as measured by device safety, effectiveness, costs of delivery of aortic surgery care, and patient quality of life domains. Additionally, the study will assess technical success and treatment success at each follow-up interval.


Description:

The primary objective of this clinical investigation is to assess the use of the TAAA Debranching Stent Graft System to repair thoracoabdominal aortic aneurysms. While surgery remains a standard treatment for complex abdominal and thoracoabdominal aneurysms (TAAA), the tolerance of some patients to recover from such extensive and invasive open aortic reconstructions is poor. Endovascular repair may offer the opportunity to reduce patient risk with less invasive approaches, improve quality of life, and serve to reduce the cost burden. The primary technical safety endpoint is freedom from major adverse events (MAE) at 30 days or during hospitalization if this exceeds 30 days. The primary effectiveness endpoint is the proportion of study subjects with treatment success at 1 year.


Recruitment information / eligibility

Status Terminated
Enrollment 2
Est. completion date June 6, 2022
Est. primary completion date March 21, 2022
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: Modified Inclusion Criteria A patient may be entered into the study if the patient has at least one of the following: - An aneurysm with a maximum diameter of > 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements - Aneurysm with a history of growth > 0.5 cm in 6 months - Saccular aneurysm deemed at significant risk for rupture - Symptomatic aneurysm greater than 4.5 cm Other inclusion criteria: - Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit - Proximal landing zone for the thoracic bifurcation stent graft that has: - = 2.5 cm of healthy/nondiseased tissue (including previously placed graft material) (neck) distal to the left subclavian artery (LSA) diameter in the range of 26-42 mm - =2.5cm of surgical graft distal to the left subclavian artery (LSA) diameter in the range of 26-42mm. - Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold - Minimum branch vessel diameter greater than 5 mm - Iliac artery distal fixation site, including both native tissue and previously placed graft, greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm - Patency of the four major visceral vessels (SMA, celiac, right renal, left renal) - Age: = 18 years old - Life expectancy: > 1 year Exclusion Criteria General exclusion - Patient is a good candidate for and elects open surgical repair - Can be treated in accordance with the instructions for use with a legally marketed endovascular prosthesis - Is eligible for enrollment in a manufacturer-sponsored investigational device exemption (IDE) at the investigational site - Unwilling to comply with the follow-up schedule - Inability or refusal to give informed consent by patient or legal representative - Patient is pregnant or breastfeeding - Patient has a contained rupture - Patient has a ruptured aneurysm - Patient has a dissection in the treated portion of the aorta - Obstructive stenting of any or all of the visceral vessels Medical exclusion criteria - Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel: Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE), platinum, gold, polyethylene, or stainless steel. - Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed - Uncorrectable coagulopathy - Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment - Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned < 30 days of the endovascular repair - Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina) - Systemic or local infection that may increase the risk of endovascular graft infection - Baseline creatinine greater than 2.0 mg/dL - History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome) Anatomical exclusion criteria - Thrombus or excessive calcification within the neck of the aneurysm - Branch stenosis = 70% - Anatomy that would not allow maintenance of at least one patent hypogastric artery - Anatomy that would not allow primary or assisted patency of the left subclavian artery

Study Design


Intervention

Device:
Visceral Manifold and Thoracic Bifurcation
Endovascular stent graft system
Unitary Manifold
Endovascular stent graft system
TAAA Debranching Stent Graft System
Endovascular stent graft system

Locations

Country Name City State
United States Johns Hopkins University Baltimore Maryland

Sponsors (1)

Lead Sponsor Collaborator
Johns Hopkins University

Country where clinical trial is conducted

United States, 

References & Publications (1)

Anderson J, Nykamp M, Danielson L, Remund T, Kelly PW. A novel endovascular debranching technique using physician-assembled endografts for repair of thoracoabdominal aneurysms. J Vasc Surg. 2014 Nov;60(5):1177-1184. doi: 10.1016/j.jvs.2014.05.090. Epub 2014 Jul 3. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Freedom From Major Adverse Events (MAEs) at 30 Days Major adverse events include death, bowel ischemia, myocardial infarction, paraplegia, renal failure, respiratory failure, and stroke. 30 days
Secondary Treatment Success at 1 Year Treatment success is defined as a composite of technical success and freedom from the following:
Aneurysm enlargement, Aneurysm rupture, Aneurysm-related mortality, Conversion to open repair, Secondary intervention for migration, Type I and III endoleaks, device integrity failure, and patency-related events.
1 year
See also
  Status Clinical Trial Phase
Not yet recruiting NCT06267573 - Thoracoabdominal Aortic Aneurysms
Recruiting NCT04526938 - Physician-modified Endovascular Graft for Repair of Complex Thoracoabdominal and Abdominal Aortic Aneurysms N/A
Active, not recruiting NCT04009512 - Endovascular Repair of Thoracoabdominal Aortic Aneurysms N/A
Enrolling by invitation NCT00583817 - Endovascular Treatment of Thoracic Aortic Disease N/A
Completed NCT02528500 - GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis in the Treatment of Type IV Thoracoabdominal Aortic Aneurysms N/A
Not yet recruiting NCT06103942 - Automated Carbon Dioxide Angiography in Fenestrated/Branched Endovascular Abdominal Aortic Aneurysm Repair
Recruiting NCT05896397 - European Aortic Data Collection Project
Recruiting NCT00483249 - Endovascular Exclusion of Thoracoabdominal and/or Paravisceral Abdominal Aortic Aneurysm N/A
Recruiting NCT02089607 - Complex Abdominal, TAAA, Aortic Arch Aneurysm or Dissections With Fenestrated/Branched Stent Graft N/A
Completed NCT01756911 - Evaluation of the Safety and Efficacy of the Multilayer Stent N/A
Recruiting NCT04746677 - Safety and Efficacy of Endovascular Repair of Complex Aortic Pathology With Physician-modified Endovascular Grafts (PMEGs) N/A
Recruiting NCT05339061 - Physician Modified Endograft For Complex Aortic Aneurysm Repair N/A
Recruiting NCT05195905 - PMEG for Repair of Pararenal and Thoracoabdominal Aortic Aneurysm N/A
Recruiting NCT02043691 - Evaluation of the Cook Custom Aortic Endograft, the Zenith t-Branch Endovascular Graft, and Surgeon-Modified Endograft in Treating Aortic Pathologies N/A
Recruiting NCT03728985 - Evaluation of the GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis in the Treatment of Thoracoabdominal and Pararenal Aortic Aneurysms N/A
Recruiting NCT03093857 - Investigation of the Cerebrospinal Fluid and Further Tissue Samples for Biomarker Indicating Spinal Ischemia and Organ Failure in Patients With Thoracoabdominal Aortic Aneurysm N/A
Recruiting NCT01524211 - Evaluation of Branch Endografts in the Treatment of Aortic Aneurysms N/A
Recruiting NCT05954793 - A PMCF Study in Patients With Thoracoabdominal Aortic Aneurysms Treated With E-nside TAAA Multibranch Stent Graft System (INNER-B-APAC)
Recruiting NCT05224219 - Modified Preloaded System for Renal Arteries in Fenestrated Endografting (MPSRA)
Completed NCT05956873 - Endovascular Aortic Repair of Free and Contained Ruptured Thoraco-Abdominal Aortic Aneurysm