The objective of this study is to evaluate the positional stability and quality of lung isolation provided by the EZ-blocker compared to a DLT for both right and left sided thoracic surgery. An additional objective will be to assess time to placement of both devices and other significant clinical differences between these two approaches to placement of the bronchial blocker (BB) including airway injury and post-operatives sore throat, post-operative hoarseness, Additionally we would like to examine the preoperative high resolution CT imaging data to determine if there are anatomic landmarks that may potentially inform the appropriateness or inappropriateness of choosing an EZ-blocker or left sided DLT.


Clinical Trial Description

One lung ventilation (OLV) is frequently used in thoracic surgery to promote surgical exposure and improve operative conditions. At this time, there are two different approaches to OLV in routine use in adult thoracic surgery. One approach is to use of a double lumen tube (DLT). The other approach is to use a bronchial blocker (BB). Currently there are several different types of bronchial BBs on the market. The EZ-Blocker essentially functions as a bronchial blocker with a 7-Fr shaft with two separate occlusive balloons coming off this shaft in a "Y" configuration designed to rest on the carina. Once anchored in place the operator can choose to inflate one of the two occlusive balloons to isolate one main stem bronchus or the other. A number of studies have been performed comparing BBs to DLTs looking at time and ease of placement, differences in quality of lung isolation, and incidence of sore throat, hoarseness, and other morbidity associated with placement. A recent meta-analysis published by Clayton-Smith et al found that BBs are associated with fewer airway injuries when compared to DLTs. They found the quality of isolation to be equivalent between BBs and DLTs. While quality of isolation over all may be comparable, it has been demonstrated in several studies that positional stability of bronchial blockers such as the Arndt or Cohen, is frequently inferior to that of a DLT. At this time, there are a small number of trials looking at the use of the EZ-blocker in adult patients. In one study published in 2013 the EZ-blocker was compared to the Cohen Flex-Tip blocker. In this study they found that time to place the EZ-blocker was in fact shorter and that overall the number of repositioning required was less with the EZ-blocker. In 2013, a study was published by Mourisse et al which compared DLT to the EZ-blocker. In this study they found initial malposition of both devices to be fairly equivalent, and time to placement was longer with the EZ-blocker. They also found more tracheal and bronchial injuries in the DLT group, but importantly they found that positional stability was equivalent. In both of these studies however they did not design their studies to effectively differentiate between right and left sided procedures when quantifying the need for BB repositioning. Because the takeoff of the right upper lobe bronchus is sometimes adjacent to, or proximal to the carina, it can impede effective isolation with a BB. Therefore, claims of positional stability may rely heavily on the laterality of the procedure, with right sided isolation being significantly more labile than left sided especially with respect to isolation using a BB. According to the manufactures recommendations the EZ-blocker is placed through a Y-piece adaptor included with the blocker kit. A flexible fiberoptic bronchoscope (FFB) is placed in a separate limb of this Y-piece and this fed through alongside the EZ-blocker to visualize and confirm placement of the BB. The balloon is then inflated typically under direct vision to occlude that bronchus thus isolating that lung hopefully achieving full lung isolation. In conclusion then, the study team feels that the potential morbidity of a DLT in terms of the potential for airway injury when compared to a BB suggests that further exploration of the possibility of equivalent positional stability between these devices is necessary. The team also feels that it is necessary to delineate the impact of laterality on the effectiveness of one technique for isolation versus the other. In addition to this if there is a difference in stability in cases where right sided isolation via the EZ-blocker fails in the setting of multiple repositions or out and out failure the team would like to examine the preoperative high resolution CT data to determine if there are anatomic measurement which could potentially inform the appropriateness or inappropriateness of choosing a DLT over an EZ-blocker. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03403192
Study type Interventional
Source Wake Forest University Health Sciences
Contact
Status Completed
Phase N/A
Start date January 26, 2018
Completion date October 29, 2019

See also
  Status Clinical Trial Phase
Completed NCT02537366 - Dexmedetomidine for Non-invasive Ventilation After Chest Trauma Phase 4
Completed NCT00615979 - Far Forward Battlefield Telemedicine: Evaluation of Handheld Ultrasound N/A
Completed NCT03710096 - Comparison of McGrath and Macintosh Laryngoscopes for Insertion of a Double Lumen Tube by Residents N/A
Active, not recruiting NCT00917852 - Evaluation of the GORE Conformable TAG® for Treatment of Traumatic Transection N/A
Recruiting NCT06072339 - Optimization of Positive End Expiratory Pressure by Use of Pulmonary Ultrasound for Patients With Blunt Chest Trauma Treated by Non-Invasive Ventilation (Opti-PEP). N/A
Recruiting NCT03919916 - Serratus Plane Block With Parenteral Opioid Analgesia Versus Patient Controlled Analgesia in Rib Fractures N/A
Recruiting NCT03770208 - RIB PAIN (Rib Fractures Treated With Parental Analgesia With Infused LidocaiNe) N/A
Completed NCT00228111 - TRACT Study: Evaluation of the Value of Routine Thoraco-abdominal CT in Blunt Trauma Patients N/A
Terminated NCT03540095 - Erector Spinae Plane (ESP) Versus Paravertebral Nerve (PVB) Blockade for Acute Unilateral Rib Fracture Pain N/A
Completed NCT01688050 - TRANSFIX Zenith® Transection Clinical Study N/A
Terminated NCT00295438 - Robot-based Tele-echography II - A Comparative Study N/A
Recruiting NCT03050502 - The Management of Traumatic Hemothoraces N/A
Recruiting NCT04081896 - Evaluation of the Effects of a Rehabilitation Program in Individuals With Spine Pain