Clinical Trials Logo

Clinical Trial Details — Status: Withdrawn

Administrative data

NCT number NCT05049720
Other study ID # MDT20054
Secondary ID
Status Withdrawn
Phase N/A
First received
Last updated
Start date September 2022
Est. completion date July 28, 2023

Study information

Verified date September 2022
Source Medtronic
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This study is designed to provide continued access to the Extravascular Implantable Cardioverter Defibrillator (EV ICD) System.


Description:

The study will enroll subjects who are indicated to receive an implantable defibrillator who meet all of the inclusion criteria and none of the exclusion criteria. Subjects will receive an investigational Extravascular Implantable Cardioverter Defibrillator (EV ICD) system, in which a lead is placed outside of the heart and veins to deliver defibrillation therapy. Subjects will be followed every 6 months following system implantation.


Recruitment information / eligibility

Status Withdrawn
Enrollment 0
Est. completion date July 28, 2023
Est. primary completion date July 28, 2023
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. Patient has a Class I or IIa indication for implantation of an ICD according to the ACC/AHA/HRS Guidelines.[1] 2. Patient is willing and able to sign and date the Informed Consent Form for their participation in the study. 3. Patient is at least 18 years of age and meets age requirements per local law. 4. Patient is geographically stable and willing and able to comply with the study procedures and visits for the duration of the follow-up. Exclusion Criteria: 1. Patient has indications for bradycardia pacing[2] or Cardiac Resynchronization Therapy (CRT)[3] (Class I, IIa, or IIb indication). 2. Patients with an existing pacemaker, ICD, or CRT device or leads. 3. Patients with these medical interventions are excluded from participation in the study: - Prior sternotomy - Any prior medical condition or procedure that leads to adhesions in the anterior mediastinal space (i.e., prior mediastinal instrumentation, mediastinitis) - Prior abdominal surgery in the epigastric region - Planned sternotomy - Prior chest radiotherapy Or any other prior/planned medical intervention not listed that precludes their participation in the opinion of the Investigator. 4. Patients with these medical conditions or anatomies are excluded from participation in the study: - Hiatal hernia that distorts mediastinal anatomy - Marked sternal abnormality (e.g., pectus excavatum that impedes the substernal tunneling path or procedure) - Decompensated heart failure - COPD with oxygen dependence - Gross hepatosplenomegaly Or any other known medical condition or anatomy type not listed that precludes their participation in the opinion of the Investigator. 5. Patients with a medical condition that precludes them from undergoing defibrillation testing: - Severe aortic stenosis - Current Intracardiac LA or LV thrombus - Severe proximal three-vessel or left main coronary artery disease without revascularization - Hemodynamic instability - Unstable angina - Recent stroke or transient ischemic attack (within the last 6 months) - Known inadequate external defibrillation - LVEF < 20% - LVEDD >70 mm Or any other known medical condition not listed that precludes their participation in the opinion of the Investigator. 6. Patient with any evidence of active infection or undergoing treatment for an infection. 7. Patient is contraindicated from temporary suspension of oral/systemic anticoagulation. 8. Patient with current implantation of neurostimulator or any other chronically implanted device that delivers current in the body. 9. Patient meets ACC/AHA/HRS or ESC clinical guideline Class III criteria for an ICD (e.g., life expectancy of less than 12 months). 10. Patient is enrolled or planning to enroll in a concurrent clinical study that may confound the results of this study, without documented pre-approval from a Medtronic study manager. 11. Patient with any exclusion criteria as required by local law (e.g., age or other). 12. Pregnant women or breastfeeding women, or women of childbearing potential and who are not on a reliable form of birth regulation method or abstinence* (*If required by local law, women of child-bearing potential must undergo a pregnancy test within seven days prior to EV ICD Continued Access Study procedures)

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Defibrillation using the Extravascular ICD
VT/VF induction attempted for defibrillation testing, as well as requisite electrical testing.

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Medtronic

References & Publications (3)

Al-Khatib SM, Stevenson WG, Ackerman MJ, Bryant WJ, Callans DJ, Curtis AB, Deal BJ, Dickfeld T, Field ME, Fonarow GC, Gillis AM, Granger CB, Hammill SC, Hlatky MA, Joglar JA, Kay GN, Matlock DD, Myerburg RJ, Page RL. 2017 AHA/ACC/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2018 Oct 2;72(14):e91-e220. doi: 10.1016/j.jacc.2017.10.054. Epub 2018 Aug 16. Review. Erratum in: J Am Coll Cardiol. 2018 Oct 2;72(14):1760. — View Citation

Kusumoto FM, Schoenfeld MH, Barrett C, Edgerton JR, Ellenbogen KA, Gold MR, Goldschlager NF, Hamilton RM, Joglar JA, Kim RJ, Lee R, Marine JE, McLeod CJ, Oken KR, Patton KK, Pellegrini CN, Selzman KA, Thompson A, Varosy PD. 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2019 Aug 20;74(7):e51-e156. doi: 10.1016/j.jacc.2018.10.044. Epub 2018 Nov 6. Erratum in: J Am Coll Cardiol. 2019 Aug 20;74(7):1016-1018. — View Citation

Wilkoff BL, Fauchier L, Stiles MK, Morillo CA, Al-Khatib SM, Almendral J, Aguinaga L, Berger RD, Cuesta A, Daubert JP, Dubner S, Ellenbogen KA, Mark Estes NA 3rd, Fenelon G, Garcia FC, Gasparini M, Haines DE, Healey JS, Hurtwitz JL, Keegan R, Kolb C, Kuck KH, Marinskis G, Martinelli M, McGuire M, Molina LG, Okumura K, Proclemer A, Russo AM, Singh JP, Swerdlow CD, Teo WS, Uribe W, Viskin S, Wang CC, Zhang S. 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. Heart Rhythm. 2016 Feb;13(2):e50-86. doi: 10.1016/j.hrthm.2015.11.018. Epub 2015 Dec 1. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Complications EV ICD system and/or procedure related adverse events Through study completion, an average of 18 months
See also
  Status Clinical Trial Phase
Not yet recruiting NCT05649891 - Checklists Resuscitation Emergency Department N/A
Completed NCT02941250 - Acute Defibrillation Performance of a Novel Can-less Shock Pathway N/A
Completed NCT01592669 - Passive Leg Raising Attenuates and Delays Tourniquet Deflation-induced Hypotension and Tachycardia N/A
Completed NCT00721136 - Randomized Study of the Use of Warfarin During Pacemaker or ICD Implantation in Patients Requiring Long Term Anticoagulation N/A
Completed NCT04060680 - Extravascular ICD Pivotal Study N/A
Recruiting NCT06048731 - Enlighten Study: The EV-ICD Post Approval Registry
Recruiting NCT04075084 - Observation of Clinical Routine Care for Patients With BIOTRONIK Implantable Cardiac Monitors (ICMs)
Completed NCT01772576 - Safety and Performance Study of the Reliance 4-Front Lead N/A
Completed NCT01410552 - Inappropriate Shock Reduction wIth PARAD+ Rhythm DiScrimination N/A
Completed NCT00542854 - iPod and Other MP3 Players on ICDs and Pacemakers in Children N/A
Completed NCT02877693 - A Post-market Clinical Evaluation of St. Jude Medical™ MR Conditional ICD System on Patients Undergoing Magnetic Resonance Imaging N/A
Recruiting NCT06038123 - China 3T MRI Study N/A
Completed NCT01754064 - St. Jude Medical Product Longevity and Performance (SCORE) Registry
Completed NCT00402246 - CONNECT Study - Clinical Evaluation Of Remote NotificatioN to rEduCe Time to Clinical Decision N/A
Active, not recruiting NCT03940066 - Evaluation of Ambulatory Monitoring of Patients After High-risk Acute Coronary Syndrome Using Two Different Systems: Biomonitor-2 and Kardia Mobile N/A
Completed NCT03012568 - Clinical Study to Confirm MRI Safety and Effectiveness Using St. Jude Medical (SJM) Cardiac Rhythm Management Systems
Completed NCT02772380 - Acute Study to Collect Electrical Signals From the Heart Using a Special Lead N/A
Completed NCT01377051 - Effect of Indacaterol Maleate in Chronic Obstructive Pulmonary Disease (COPD) on Lung Volume and Related Dyspnea Phase 4
Completed NCT00820625 - Long-Standing Persistant Atrial Fibrillation-Pulmonary Vein Isolation With or Without Ablation N/A
Completed NCT03720639 - Confirm Rx™ Versus Reveal LINQ™ - Which is More Reliable in Data Transmission? A Randomized Clinical Study N/A