Tachyarrhythmia Clinical Trial
Official title:
Bedside Precise Temporary Transvenous Cardiac Pacemaker Placement by Intracavitary Electrocardiogram Monitoring
Traditional temporary pacing catheter insertion by intracavitary electrocardiogram (IC-ECG) monitoring which only monitoring tip polar, the negative one. The investigators modified the technique by monitoring both negative and positive polar which will be precisely locating catheter tip and indicating the direction of the catheter tip. Extensively used temporary pacing catheter tip has two electrodes which are about 1 cm apart. Distal electrode is negative (-) and active, proximal electrode is positive (+) and indifferent. Investigators use both distal (-) and proximal (+) electrodes which can be attached to any two of the V leads, record as V(-) and V(+). Monitoring positions of the electrodes by V(-) and V(+) could provide more information about the tip position. Comparing the QRS amplitudes between V(-) and V(+), when catheter tip enters right ventricle chamber: the case of V(-) > V(+) infers tip toward apex ventricle wall ; conversely, the case of V(-)<V(+) indicates tip directs to outflow tract. The investigators hypothesis this monitoring will help precisely placement.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02849769 -
Magnetic Resonance (MR) Conditional Tachyarrhythmia Therapy Products Post-approval Study
|
||
Completed |
NCT02565238 -
BIO.MASTER.BioMonitor 2 Study
|
N/A | |
Completed |
NCT04025710 -
Master Study of the BIOMONITOR III and Incision and Insertion Tool (FIT OneStep)
|
N/A | |
Active, not recruiting |
NCT05621187 -
Post Market Clinical Follow-up Study for the Pamira ICD Lead Family
|
N/A | |
Not yet recruiting |
NCT06382207 -
Effectiveness of the Eko Digital Stethoscope in Capturing Infant ECGs
|
N/A | |
Active, not recruiting |
NCT01526629 -
Full Automaticity and Remote Follow-up
|
N/A | |
Completed |
NCT03850327 -
BIO|CONCEPT.BIOMONITOR III
|
N/A | |
Completed |
NCT03408951 -
Surface ECG Signal Recording for the Implantable Subcutaneous String Defibrillator (ISSD) Detection Algorithm Performance Assessment
|
||
Not yet recruiting |
NCT06327425 -
MCG for Localization of Tachyarrhythmia's Origin
|
N/A | |
Recruiting |
NCT04863664 -
Lead EvaluAtion for Defibrillation and Reliability (LEADR) / Lead Evaluation for Defibrillation and Reliability in Left Bundle Branch Area Pacing (LEADR LBBAP)
|
N/A | |
Not yet recruiting |
NCT05750108 -
Transcutaneous Vagal Nerve Stimulation to Prevent Tachyarrhythmias in Patients Early Following Myocardial Infarction
|
N/A | |
Completed |
NCT02774616 -
BIO|MASTER.Ilivia Family / Plexa
|
N/A | |
Completed |
NCT00231426 -
ASSURE Study - Arrhythmia Single Shock DFT Versus ULV: Risk Reduction Evaluation With ICD Implantations
|
Phase 4 | |
Completed |
NCT02181686 -
Iperia/Sentus QP Study
|
N/A | |
Terminated |
NCT03451227 -
Dexmedetomidine and Fentanyl Versus Midazolam and Remifentanil for Sedation in Patients Undergoing Ablation Procedures
|
N/A | |
Completed |
NCT02933619 -
ProMRI ICD/CRT-D Post Approval Study
|
||
Completed |
NCT00324662 -
Study to Verify Proper Detection of Supraventricular Tachyarrhythmia With Single-Lead Dual-Chamber Implantable Cardioverter-Defibrillators (ADRIA)
|
Phase 4 | |
Completed |
NCT00170274 -
APART: Prevention and Automatic Therapy of Atrial Arrhythmias in Patients With Paroxysmal Supraventricular Tachycardias
|
N/A | |
Completed |
NCT03891329 -
Master Study of the Acticor/Rivacor ICDs/CRT-Ds and the Plexa ProMRI S DX Lead
|
N/A | |
Completed |
NCT06323499 -
Outcome of Induced Atypical Atrial Flutter
|