Clinical Trials Logo

Clinical Trial Summary

This study investigates the possible differences in images obtained in patients with lumbar spondylolisthesis when positioned in an upright weight bearing position compared with traditional supine positioning for lumbar MRI.


Clinical Trial Description

Detailed Description Spondylolisthesis is a spinal condition in which one vertebral body has slid forward in relation to the vertebrae below and is sometimes associated with spinal instability. Lumbar spondylolisthesis is a relatively common problem and is generally diagnosed from radiographs. MRI is often used to evaluate the condition further and to determine if there is nerve root compression involved. One potential disadvantage with traditional MRI to evaluate spondylolisthesis is imaging is performed with the patient lying supine in the scanner. This creates a potential for the superior vertebra to slide posteriorly so that the extent of the slip may not be fully appreciated, if seen at all. Use of upright weight bearing MRI provides the opportunity to image the spine in the position that patients are most likely to experience symptoms and is similar to standing radiographs.

MRI Acquisition: Each patient will undergo MRI scanning in the supine and weight bearing positions during the same imaging session. If it is determined that a patient who has consented to participate in the study should not have an MRI made due to safety concerns (such as metallic implant or other contraindication to MRI not identified during recruiting), they will be discontinued from the study and another patient recruited to fulfill the planned number of images available for analysis.

The MRI procedure will be standard lumbar spine scanning protocol using the Esaote G-scan, an open unit. Patients will be scanned supine and then the unit rotated to 81 degrees from horizontal for the weight bearing scan. Immediately after each scan, the patient will complete visual analog scales (VAS) assessing back and leg pain.

Researcher(s) performing image assessments will be blinded to the position in which scans were made. Data to be recorded for each image is the Meyerding scale (1-4 scale rating the severity of the spondylolisthesis), amount of slip (mm), anterior and posterior disc space height (mm), foraminal area, anteroposterior (AP) distance at the most narrow part of the foramen, and disc space angulation. Area of the spinal canal and AP distance across the canal will be measured from axial images. The facet fluid sign, associated with spinal instability, will be assessed from axial MRI views using a 3-point scale with "none" indicating no evidence of fluid in the left or right facet joints; "possible" if there is some suggestion of fluid in the joints; or "definite" if there is at least a 2 mm wide layer of hyperintensity within either joint bilaterally at the level evaluated. Additionally, the width of the fluid fill of the facet joint taken perpendicular to the apparent joint line, and the largest value recorded as effusion size.

Clinical Assessments: VAS separately assessing back and leg pain will be completed immediately after the supine scanning and again immediately after weight bearing scanning. Analysis will be conducted to determine if differences in pain correlate with changes in images taken in the two positions.

Statistical methods: Parametric measures will be compared for the two imaging positions using paired t-tests. Pairwise categorical data will be analyzed using McNemar analysis. In the secondary study dealing with facet fluid sign, mean values for translation, disc height, foraminal area, and AP distance will be compared across the three facet fluid sign categories using ANOVA.

Changes in back and leg pain will be analyzed to determine if there is a relationship between these changes and changes noted on the positional MRI. It is not anticipated that this section of the study will produce statistically significant results, but will hopefully provide guidance for possibly investigating these parameters in future studies.

From routine clinical lateral flexion/extension radiographs, change in translation between the two positions will be measured. If a lateral neutral radiograph is available, translation as well as anterior and posterior disc height will be measured. All measurements will be made using the same methods as described for the MRIs.

Sample size: At least 25 patients, but no more than 60 patients will be included. After 25 patients are imaged, data will be analyzed to determine an appropriate sample size to determine a statistically significant difference between measurements made from the supine and upright weight bearing images. ;


Study Design

Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Diagnostic


Related Conditions & MeSH terms


NCT number NCT02958241
Study type Interventional
Source Texas Back Institute
Contact
Status Enrolling by invitation
Phase N/A
Start date November 2016
Completion date November 2018

See also
  Status Clinical Trial Phase
Recruiting NCT03883022 - Vancomycin Powder Combined With Autogenous Bone Graft as a Prevention for Post-operative Infection for Spine Surgery N/A
Active, not recruiting NCT04542577 - PMCF Study on the Safety and Performance of PROSPACE 3D / PROSPACE 3D OBLIQUE / TSPACE 3D
Recruiting NCT04477447 - PMCF Study on the Safety and Performance of CESPACE 3D
Completed NCT02558621 - New Robotic Assistance System for Spinal Fusion Surgery N/A
Terminated NCT01461005 - A Postmarket Surveillance Study of the Paradigm Spine Dynamic Stabilization System (DSS) N/A
Completed NCT00405691 - Safety and Effectiveness Study of the TOPS System, a Total Posterior Arthroplasty Implant Designed to Alleviate Pain Resulting From Moderate to Severe Lumbar Stenosis Phase 3
Completed NCT00205101 - Clinical Outcome Study of the Triad Allograft for Posterior Lumbar Fusion
Enrolling by invitation NCT04204135 - The Course of Hip Flexion Weakness Following LLIF or ALIF
Recruiting NCT05238740 - Comparison of Standalone Anterior Lumbar Interbody Fusion (ALIF) L5/S1 Performed With Either rhBMP-2 or ViviGen® N/A
Not yet recruiting NCT02805985 - Post-market Surveillance Study of FLXfit™ TLIF Interbody Fusion Device N/A
Completed NCT02966639 - Validation of Appropriateness Criteria for the Surgical Treatment of Lumbar Degenerative Spondylolisthesis
Completed NCT02931279 - PASS OCT® Post-market Clinical Follow-up
Active, not recruiting NCT02057744 - MIS ReFRESH: Robotic vs. Freehand Minimally Invasive Spinal Surgeries
Completed NCT01711203 - The Addition of a Pilates Program for Short-Term Improvements in Patients With Spondylolysis or Spondylolisthesis N/A
Completed NCT00549913 - Study of 3 Doses of NeoFuse Combined With MasterGraft Granules in Subjects Requiring Posterolateral Lumbar Fusion (PLF) Phase 1/Phase 2
Terminated NCT00254852 - Evaluation of Radiographic and Patient Outcomes Following Lumbar Spine Fusion Using Demineralized Bone Matrix (DBM) Mixed With Autograft N/A
Terminated NCT00095095 - Lumbar Interbody Fusion Using the Telamon® Peek™ Versus the Telamon® Hydrosorb™ Fusion Device Phase 4
Active, not recruiting NCT03956537 - PMCF Neo Pedicle Screw and Cage Systems
Recruiting NCT05182489 - Adaptix RCT Evaluating Adaptix™ Versus PEEK Cages N/A
Completed NCT02884440 - Transverse Abdominis Plane Block for Anterior Approach Spine Surgery Phase 2