Spondylolisthesis Clinical Trial
Official title:
Supine vs. Upright Weight Bearing MRI in the Evaluation of Patients With Lumbar Spondylolisthesis
This study investigates the possible differences in images obtained in patients with lumbar spondylolisthesis when positioned in an upright weight bearing position compared with traditional supine positioning for lumbar MRI.
Detailed Description Spondylolisthesis is a spinal condition in which one vertebral body has
slid forward in relation to the vertebrae below and is sometimes associated with spinal
instability. Lumbar spondylolisthesis is a relatively common problem and is generally
diagnosed from radiographs. MRI is often used to evaluate the condition further and to
determine if there is nerve root compression involved. One potential disadvantage with
traditional MRI to evaluate spondylolisthesis is imaging is performed with the patient lying
supine in the scanner. This creates a potential for the superior vertebra to slide
posteriorly so that the extent of the slip may not be fully appreciated, if seen at all. Use
of upright weight bearing MRI provides the opportunity to image the spine in the position
that patients are most likely to experience symptoms and is similar to standing radiographs.
MRI Acquisition: Each patient will undergo MRI scanning in the supine and weight bearing
positions during the same imaging session. If it is determined that a patient who has
consented to participate in the study should not have an MRI made due to safety concerns
(such as metallic implant or other contraindication to MRI not identified during
recruiting), they will be discontinued from the study and another patient recruited to
fulfill the planned number of images available for analysis.
The MRI procedure will be standard lumbar spine scanning protocol using the Esaote G-scan,
an open unit. Patients will be scanned supine and then the unit rotated to 81 degrees from
horizontal for the weight bearing scan. Immediately after each scan, the patient will
complete visual analog scales (VAS) assessing back and leg pain.
Researcher(s) performing image assessments will be blinded to the position in which scans
were made. Data to be recorded for each image is the Meyerding scale (1-4 scale rating the
severity of the spondylolisthesis), amount of slip (mm), anterior and posterior disc space
height (mm), foraminal area, anteroposterior (AP) distance at the most narrow part of the
foramen, and disc space angulation. Area of the spinal canal and AP distance across the
canal will be measured from axial images. The facet fluid sign, associated with spinal
instability, will be assessed from axial MRI views using a 3-point scale with "none"
indicating no evidence of fluid in the left or right facet joints; "possible" if there is
some suggestion of fluid in the joints; or "definite" if there is at least a 2 mm wide layer
of hyperintensity within either joint bilaterally at the level evaluated. Additionally, the
width of the fluid fill of the facet joint taken perpendicular to the apparent joint line,
and the largest value recorded as effusion size.
Clinical Assessments: VAS separately assessing back and leg pain will be completed
immediately after the supine scanning and again immediately after weight bearing scanning.
Analysis will be conducted to determine if differences in pain correlate with changes in
images taken in the two positions.
Statistical methods: Parametric measures will be compared for the two imaging positions
using paired t-tests. Pairwise categorical data will be analyzed using McNemar analysis. In
the secondary study dealing with facet fluid sign, mean values for translation, disc height,
foraminal area, and AP distance will be compared across the three facet fluid sign
categories using ANOVA.
Changes in back and leg pain will be analyzed to determine if there is a relationship
between these changes and changes noted on the positional MRI. It is not anticipated that
this section of the study will produce statistically significant results, but will hopefully
provide guidance for possibly investigating these parameters in future studies.
From routine clinical lateral flexion/extension radiographs, change in translation between
the two positions will be measured. If a lateral neutral radiograph is available,
translation as well as anterior and posterior disc height will be measured. All measurements
will be made using the same methods as described for the MRIs.
Sample size: At least 25 patients, but no more than 60 patients will be included. After 25
patients are imaged, data will be analyzed to determine an appropriate sample size to
determine a statistically significant difference between measurements made from the supine
and upright weight bearing images.
;
Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Diagnostic
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT03883022 -
Vancomycin Powder Combined With Autogenous Bone Graft as a Prevention for Post-operative Infection for Spine Surgery
|
N/A | |
Active, not recruiting |
NCT04542577 -
PMCF Study on the Safety and Performance of PROSPACE 3D / PROSPACE 3D OBLIQUE / TSPACE 3D
|
||
Recruiting |
NCT04477447 -
PMCF Study on the Safety and Performance of CESPACE 3D
|
||
Completed |
NCT02558621 -
New Robotic Assistance System for Spinal Fusion Surgery
|
N/A | |
Terminated |
NCT01461005 -
A Postmarket Surveillance Study of the Paradigm Spine Dynamic Stabilization System (DSS)
|
N/A | |
Completed |
NCT00405691 -
Safety and Effectiveness Study of the TOPS System, a Total Posterior Arthroplasty Implant Designed to Alleviate Pain Resulting From Moderate to Severe Lumbar Stenosis
|
Phase 3 | |
Completed |
NCT00205101 -
Clinical Outcome Study of the Triad Allograft for Posterior Lumbar Fusion
|
||
Enrolling by invitation |
NCT04204135 -
The Course of Hip Flexion Weakness Following LLIF or ALIF
|
||
Recruiting |
NCT05238740 -
Comparison of Standalone Anterior Lumbar Interbody Fusion (ALIF) L5/S1 Performed With Either rhBMP-2 or ViviGen®
|
N/A | |
Not yet recruiting |
NCT02805985 -
Post-market Surveillance Study of FLXfit™ TLIF Interbody Fusion Device
|
N/A | |
Completed |
NCT02966639 -
Validation of Appropriateness Criteria for the Surgical Treatment of Lumbar Degenerative Spondylolisthesis
|
||
Completed |
NCT02931279 -
PASS OCT® Post-market Clinical Follow-up
|
||
Active, not recruiting |
NCT02057744 -
MIS ReFRESH: Robotic vs. Freehand Minimally Invasive Spinal Surgeries
|
||
Completed |
NCT01711203 -
The Addition of a Pilates Program for Short-Term Improvements in Patients With Spondylolysis or Spondylolisthesis
|
N/A | |
Completed |
NCT00549913 -
Study of 3 Doses of NeoFuse Combined With MasterGraft Granules in Subjects Requiring Posterolateral Lumbar Fusion (PLF)
|
Phase 1/Phase 2 | |
Terminated |
NCT00254852 -
Evaluation of Radiographic and Patient Outcomes Following Lumbar Spine Fusion Using Demineralized Bone Matrix (DBM) Mixed With Autograft
|
N/A | |
Terminated |
NCT00095095 -
Lumbar Interbody Fusion Using the Telamon® Peek™ Versus the Telamon® Hydrosorb™ Fusion Device
|
Phase 4 | |
Active, not recruiting |
NCT03956537 -
PMCF Neo Pedicle Screw and Cage Systems
|
||
Recruiting |
NCT05182489 -
Adaptix RCT Evaluating Adaptix™ Versus PEEK Cages
|
N/A | |
Completed |
NCT02884440 -
Transverse Abdominis Plane Block for Anterior Approach Spine Surgery
|
Phase 2 |