Clinical Trials Logo

Clinical Trial Summary

Radiation therapy is a cornerstone in the treatment of spinal neoplasms as radical resections are often limited anatomically. Frequently, a surgical stabilization with implants is required. However, metallic implants not only make the CT-based planning of a subsequent radiation therapy more difficult, but might also have an uncontrolled dose modulating effect in adjuvant radiotherapy. At the spine, radiation is limited by the effective dose posed to the relatively radiosensitive spinal cord. While metallic implants might result in an inhomogeneous and uncontrollable dose distribution due to the interface effect, the use of new radiolucent implants consisting of carbon/polyether ether ketone (PEEK) might allow a more homogeneous and predictable dose distribution. This study aims to evaluate the potential benefits of the use of carbon/PEEK pedicle screws during adjuvant radiation therapy and follow-up imaging of spinal tumors.

60 patients will randomized 1:1 into either treatment arm (Pedicle System Carbon/PEEK vs. Pedicle System Titanium). The feasibility of planning the radiation therapy will be evaluated. The postoperatively administered total radiation dose is documented. The radiological visualization of the area of interest will be evaluated The surgical outcome is evaluated by fusion rate, implant integrity and anchorage. Patients will be followed up for 12 months according to local standards.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT03893110
Study type Interventional
Source Balgrist University Hospital
Contact
Status Withdrawn
Phase N/A
Start date June 27, 2018
Completion date March 31, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT03668522 - Clinical Research of H3F3AK27M in Spinal Glioma and Its Impact on TMZ Chemoradiotherapy
Active, not recruiting NCT03956537 - PMCF Neo Pedicle Screw and Cage Systems
Completed NCT03585699 - Percutaneous Fluoroscopic vs CT Guided Core Needle Biopsy for Spinal Infection and Tumor N/A
Completed NCT04578691 - Study to Evaluate the Safety and Clinical Outcome of Using Navigation System in Pedicle Screw Placement in Spine Surgery N/A
Not yet recruiting NCT06161974 - Study of Olutasidenib and Temozolomide in HGG Phase 2
Completed NCT01624220 - A Prospective Study Using Implanted Fiducial Markers to Assess Treatment Accuracy and Esophageal Toxicity in Spinal Stereotactic Body Radiation Therapy N/A
Not yet recruiting NCT05369689 - Stereotactic Radiosurgery Prognosis Assessment for Spinal Tumors Based on Radiomics
Recruiting NCT05296889 - Post-Market Clinical Follow-Up Study on the Safety and Performance of Ennovate® Cervical
Completed NCT02252185 - A Clinical Study of a Spine Fusion System in Vertebral Body Fusion Surgery N/A
Recruiting NCT06120426 - En Bloc Resection Versus Separation Surgery Combined With Radiotherapy for the Treatment of Spinal Oligometastatic Tumor.
Recruiting NCT05170815 - Clariance ErYs Registry
Active, not recruiting NCT03052738 - Medical Marijuana in the Pediatric Central Nervous System Tumor Population
Completed NCT04952818 - The Value of Preoperative Diagnosis and Prognostic Prediction Based on Radiomics of Giant Cell Tumor of Spine
Recruiting NCT03398915 - The European Robotic Spinal Instrumentation (EUROSPIN) Study
Recruiting NCT04217525 - Duke Spine Outcome Study (DSOS)
Enrolling by invitation NCT05106179 - The Efficacy and Safety of Beta-blockers Drugs in Adults With Spinal Hemangioma Phase 4
Completed NCT02613390 - Safety Evaluation of Intra-Operative MRI-Based Guidance for Laser Ablation of Epidural Metastasis N/A
Completed NCT02790294 - Optimal Timing of Postoperative Magnetic Resonance Imaging (MRI) in Patients With Extradural Spinal N/A
Not yet recruiting NCT05396222 - A Prospective Study of the Safety and Efficacy of 3D-printed Non-rigid Biomimetic Implant in Cervical and Thoracolumbar Spine N/A
Recruiting NCT05631002 - Chemical Shift Encoding-based Water-fat Magnetic Resonance Imaging in Spinal Tumors