Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT03625830
Other study ID # AAG-G-H-1518
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date December 18, 2017
Est. completion date December 30, 2019

Study information

Verified date August 2018
Source B. Braun Medical International Trading Company Ltd.
Contact Jun Bo Ge
Phone +86 21 64041990
Email lcsyjg@zs-hospital.sh.cn
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose is to evaluate the safety and effectiveness of paclitaxel-releasing coronary balloon (Catheter SeQuent® Please) versus rapid exchange PTCA balloon catheter (SeQuent® Neo) in the treatment of stenoses of coronary small vessels. 270 subjects will be enrolled for the trials.


Recruitment information / eligibility

Status Recruiting
Enrollment 270
Est. completion date December 30, 2019
Est. primary completion date August 30, 2019
Accepts healthy volunteers No
Gender All
Age group 18 Years to 80 Years
Eligibility Inclusion Criteria:

Criteria related to subjects

- Patients with stable angina pectoris, or unstable angina pectoris, or old myocardial infarction, or documented silent ischemia;

- At the age of 18-80;

- Women of childbearing potential may not be pregnant nor have the desire to becoming pregnant during the study. Hence, patients will be advised to use an adequate birth control method up to (including) the end of follow-up;

- Patients must agree to undergo the 9-month angiographic follow-up and the clinical follow-up at 30 days, 6 months, 9 months and 12 months after operation;

- Patients who are psychologically and linguistically able to understand the purpose of the study, and show sufficient compliance with the study protocol;

- Patients who have expressed acknowledgment of the risks and benefits described in the informed consent document by providing informed consent;

Criteria related to lesions

- The target lesion is primary, in situ coronary artery lesion located in 1 or 2 different coronary arteries, with no more than 1 target lesion in each coronary artery;

- The reference vessel diameter is within the range of 2.0 mm - 2.75 mm; (visually measured)

- Interventional treatment should be conducted on lesion(s) of non-target vessel(s) in advance (which must be concurrent treatment), and management of random and target lesions should be performed after successful treatment of non-target lesion(s);

- The pre-operative diameter stenosis must be either = 70% or = 50% with ischemia; (visually measured)

- Each target lesion should be treated with only one SeQuent® Please or SeQuent® Neo.

Exclusion Criteria:

Criteria related to subjects

- Patients with recent myocardial infarction (within one week), or patients with myocardial infarction over one week but whose troponin level has not recovered to normal;

- Patients with severe congestive heart failure or NYHA class IV heart failure;

- Patients with severe valvular heart disease;

- Women who are pregnant or lactating;

- Patients with remaining life expectancy of no more than 1 year or with factors causing difficulty in clinical follow-up;

- Patients who had cerebral stroke within 6 months before operation;

- Patients who are currently involved in any other clinical trial;

- Patients with presence or history of severe hepatic failure and therefore are not eligible for angiography;

- Patients with presence or history of severe renal failure (GFR < 30 ml/min) and therefore are not eligible for angiography;

- Patients who have received heart transplant;

- Patients with cardiogenic shock;

- Patients with left ventricular ejection fraction less than 30%;

- Patients suffering from coronary artery spasm without significant stenosis;

- Patients considered as ineligible by the investigator for other reasons;

Criteria related to lesions

- Evidence of extensive thrombosis in target vessel before intervention;

- Percutaneous coronary intervention of venous graft;

- Chronic total occlusion (TIMI 0 flow before operation);

- Left main disease and/or triple vessel disease needed to be treated, bifurcation lesion with branch vessel diameter = 2.5 mm, and bypass graft lesion;

- There is non-target lesion(s) in the proximal large vessel and target lesion(s) in the distal small vessel of the same vessel (eligible if there is non-target lesion(s) in proximal large vessel and a target lesion in the bifurcated small vessel);

- The target vessel is distorted or has calcified lesion(s);

- Lesion within 5 mm away from the coronary artery ostium;

- Lesion that cannot be treated with PTCA or other interventional techniques;

- After pre-dilation of target lesion, the residual stenosis is = 30% or TIMI flow is < 3, and/or type C or above dissection appears;

Exclusion criteria related to concomitant medication

- Patients prone to bleeding and contraindicated for anticoagulant or antiplatelet drugs;

- Patients who are intolerant to aspirin and/or clopidogrel or have a history of neutrophilopenia or thrombocytopenia, or patients with severe hepatic insufficiency and contraindicated for clopidogrel.

- Patients who are known to be intolerant or allergic to heparin, contrast agent, paclitaxel, iopromide, rapamycin, polylactic acid - glycolic acid polymer, stainless steel;

- Patients with a history of leukopenia (leukocyte count < 3 × 109/L for more than 3 days), neutrophilopenia (ANC < 1,000 neutrophils/mm3 for more than 3 days), or thrombocytopenia (< 100,000 platelets/mm3);

- Patients with a history of peptic ulcer or gastrointestinal bleeding in the past 6 months

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Paclitaxel-eluting PTCA-Balloon Catheter(SeQuent® Please)
SeQuent® Please in length of 10 mm, 15 mm, 17 mm, 20 mm, 26 mm, 30 mm and in diameter of 2.0 mm, 2.5mm, 2.75mm will be used in the trial.
rapid exchange PTCA -Balloon Catheter (SeQuent® Neo)
SeQuent® Please in length of 10 mm, 15 mm, 17 mm, 20 mm, 26 mm, 30 mm and in diameter of 2.0 mm, 2.5mm, 2.75mm will be used in the trial.

Locations

Country Name City State
China Zhongshan Hospital Fudan University Shanghai Shanghai

Sponsors (1)

Lead Sponsor Collaborator
B. Braun Medical International Trading Company Ltd.

Country where clinical trial is conducted

China, 

Outcome

Type Measure Description Time frame Safety issue
Primary Late lumen loss in segment section at M9 To measure the diameter loss in the in-segment late lumen loss (LLL) at 9 months after operation by using angiography 9 months
See also
  Status Clinical Trial Phase
Recruiting NCT05300997 - Translational Immunodiagnostics in Stroke (TrImS)
Recruiting NCT06159140 - Small Vessel Diseases: Ultra-realistic Microstructure Computational Model to Refine Individual Treatment N/A