Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT00743561
Other study ID # CHUBX - 2007/04
Secondary ID
Status Completed
Phase N/A
First received August 28, 2008
Last updated April 27, 2012
Start date June 2008
Est. completion date January 2011

Study information

Verified date April 2012
Source University Hospital, Bordeaux
Contact n/a
Is FDA regulated No
Health authority France: Afssaps - Agence française de sécurité sanitaire des produits de santé (Saint-Denis)
Study type Interventional

Clinical Trial Summary

The purpose of this study is to determine whether ambulatory polygraphy during a short hospitalization in a neurology unit has the same performance than inpatient polysomnography, the actual gold standard, in the diagnosis of sleep apnea in patients suffering from multiple system atrophy (MSA).


Description:

MSA patients frequently show sleep apnea. Inpatient polysomnography is currently the gold standard in the diagnosis of sleep apnea. However, its limited availability and high costs restrain a systematic screening of MSA patients. In contrast, ambulatory polygraphy is easy to achieve during a short hospitalization in a neurology unit or at the patient's home. Its validity in MSA is unknown.

The purpose of this study is to assess whether ambulatory polygraphy realized during a short hospitalization in a neurology unit has the same performance than inpatient polysomnography in the diagnosis of sleep apnea in MSA patients. Polygraphy recordings will also be done during daytime to characterize diurnal respiratory disturbances.

Principal Objective :

To assess the performance of ambulatory polygraphy in the diagnosis of sleep apnea in MSA patients in comparison to polysomnography (reference test).

Secondary Objectives :

To assess the performance of ambulatory polygraphy in the diagnosis of sleep apnea in comparison to polysomnography in two subgroups of MSA patients: one at high risk and one at low risk according to the results of the Berlin Questionnaire and the Epworth Sleepiness Scale.

To assess the inter-rater agreement of ambulatory polygraphy. To assess the association between sleep apnea and (i) the severity of MSA, (ii) the quality of life, (iii) the quality of sleep, and (iv) the presence of depression.

To assess the association between the severity of sleep apnea and (i) the severity of MSA, (ii) the quality of life, (iii) the quality of sleep and (iv) the presence of depression.

To assess diurnal respiratory disturbances in MSA by performing polygraphical recordings during daytime.

To assess the association of diurnal respiratory disturbances in MSA and (i) the severity of MSA and (ii) the quality of life.

Study design :

Cross-sectional prospective study (delay of one month between ambulatory polygraphy during a short hospitalization in a neurology unit and inpatient polysomnography). Each test will be carried out an interpreted blind to the other test.

Study plan:

Visit of Selection (V0)

- Verification of eligibility

- Study related information Visit of inclusion (From 0 to 90 days after selection)

- Verification of eligibility

- Diagnosis criteria

- Oral informed consent of patient or representative

- Clinical examination by using UMSARS, MMSE, Berlin Questionnaire, Epworth Sleepiness Scale, PSQI, MSA-QoL, SF-36 and Beck Depression Inventory

- Ambulatory polygraphy during a short hospitalization in a neurology unit Visit of follow-up (V2, 1 month ± 5 days after V1)

- Clinical examination by using UMSARS, Berlin Questionnaire and Epworth Sleepiness Scale

- Inpatient polysomnography

Number of subjects :

30 patients (estimation of 15 patients at high risk of having sleep apnea and 15 patients at low risk).


Recruitment information / eligibility

Status Completed
Enrollment 30
Est. completion date January 2011
Est. primary completion date December 2010
Accepts healthy volunteers No
Gender Both
Age group 30 Years to 80 Years
Eligibility Inclusion Criteria:

- Diagnosis of "probable" MSA according to current consensus criteria (Gilman et al. 1999, PMID 10223419)

- Age 30-80 years

- Oral informed consent of patient or representative

- Patient requiring hospitalization in a neurology unit

Exclusion Criteria:

- Progressive cancer

- Significant cognitive impairment (MMSE<24)

- Sleep apnea

- Respiratory disorder

- Less than one year since previous polysomnography or ambulatory polygraphy

Study Design

Intervention Model: Single Group Assignment, Masking: Single Blind (Outcomes Assessor), Primary Purpose: Diagnostic


Intervention

Device:
Polysomnography
Simultaneous recording of electro-encephalography, tibial and submental electro-myography, electro-oculography, nasal air flow, oxygen saturation, as well as the thoracic and abdominal respiratory effort
ambulatory polygraphy
Simultaneous recording of nasal air flow, oxygen saturation, as well as the abdominal and thoracic respiratory effort.

Locations

Country Name City State
France CHU de Bordeaux - Hôpital Pellegrin Bordeaux
France CHU de Bordeaux - Hôpital du Haut-Lévêque - Département de Neurologie - Centre de référence nationale maladie rare AMS Pessac

Sponsors (1)

Lead Sponsor Collaborator
University Hospital, Bordeaux

Country where clinical trial is conducted

France, 

Outcome

Type Measure Description Time frame Safety issue
Primary Assessment of the performance of ambulatory polygraphy in the diagnosis of sleep apnea in comparison to polysomnography. Sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios will be calculated. 1 month No
Secondary Assessment of the performance of ambulatory polygraphy in the diagnosis of sleep apnea in comparison to polysomnography in two subgroups (high vs low risk for sleep apnea). Performances of the tests will be compared between the two sub-groups. 1 month No
Secondary Assessment of the performance of ambulatory polygraphy in the diagnosis of sleep apnea in comparison to polysomnography for different AHI thresholds (ROC curve analysis). 1 month No
Secondary Assessment of inter-rater variability by (i) calculating the intraclass correlation coefficient and its confidence interval (95%) for estimation of apnea/hypopnea index, and (ii) calculating kappa coefficient for SAOS diagnostic (dichotomous variable). 1 month No
Secondary Assessment of the association between sleep apnea and: severity of MSA (UMSARS), quality of life (MSA-Qol, SF-36), quality of sleep (PSQI) and depression (BDI). 1 month No
Secondary Assessment of the association between the severity of sleep apnea and: severity of MSA (UMSARS), quality of life (MSA-Qol, SF-36), quality of sleep (PSQI) and depression (BDI). 1 month No
Secondary Assessment of diurnal respiratory disturbances: 1. calculation of the AHI and the indices of obstructive and central respiratory events; description of all type of abnormal respiratory pattern. 1 month No
Secondary Assessment of the association between diurnal respiratory disturbances and: 1. the severity of MSA as measured by the UMSARS 2. the quality of life as measured by the MSA-QoL and SF-36 1 month No
See also
  Status Clinical Trial Phase
Recruiting NCT05477719 - Effect of Compression Stockings on the Number of Apneas/Hypopneas Per Hour of Sleep in Patients With Syndrome Obstructive Sleep Apnea/Hypopnea as Compared to no Treatment N/A
Completed NCT04979234 - A Single Centre, Prospective Feasibility Study to Evaluate the Efficacy of an Endoluminal-suturing Device (Endomina) on Severe Obstructive Sleep Apnea Syndrome N/A
Terminated NCT02735694 - Cycloserine in the Treatment of Sleep Apnea Phase 1
Active, not recruiting NCT02470182 - Screening for Sleep Disordered Breathing With Minimally Obtrusive Sensors
Completed NCT02088723 - Testing the Elevation as Sleep Apnea Treatment N/A
Completed NCT01457014 - Sleep Disordered Breathing and Chronic Pain N/A
Completed NCT00860743 - Respiratory and Autonomic Plasticity Following Intermittent Hypoxia Early Phase 1
Completed NCT00976417 - Mechanisms of Action of Adaptive Servoventilation N/A
Active, not recruiting NCT00371293 - The Effects of Obesity and Obstructive Sleep Apnea on Inflammation and Heart Disease N/A
Completed NCT00607893 - Efficacy of Continuous Positive Airway Pressure in Reducing Oxidative Stress in Individuals With Sleep Apnea N/A
Completed NCT00083798 - Family Linkage Study of Obstructive Sleep Apnea (OSA) in Iceland N/A
Completed NCT00070681 - Outcomes of Sleep Disorders in Older Men Phase 3
Completed NCT00089752 - Continuous Positive Airway Pressure to Improve Milder Obstructive Sleep Apnea N/A
Completed NCT00046670 - Sleep Disordered Breathing, APOE, and Lipid Metabolism N/A
Completed NCT00051363 - Apnea Positive Pressure Long-Term Efficacy Study Phase 3
Completed NCT00031239 - Sleep Apnea in Look AHEAD Participants - Ancillary to Look AHEAD N/A
Terminated NCT00006321 - Neurocognitive Function in Snoring Children N/A
Completed NCT00006323 - Neurobehavioral Consequences of Sleep Apnea in Children N/A
Completed NCT00005511 - SCOR in Neurobiology of Sleep--Intermediate Traits for Sleep Apnea N/A
Completed NCT00005275 - Sleep Heart Health Study (SHHS) Data Coordinating Center N/A