Clinical Trials Logo

Clinical Trial Summary

Obstructive sleep apnea (OSA) is a condition of disordered breathing characterised by intermittent partial and/or complete upper airway obstruction during sleep. The participants, naive to nasal continuous positive airway pressure (CPAP), recently diagnosed with OSA, will undergo two automatic CPAP titration studies with collection of polysomnographic (PSG) data. The data will be analysed to assess effectiveness of Compumedics auto-CPAP device in the normalisation of sleep disordered breathing in OSA patients, with respect to another auto-CPAP device.


Clinical Trial Description

Auto-titrating CPAP (APAP) using algorithms based on detection of flow limitation and snoring have been developed. Auto-titration devices adjust nasal pressure to the minimum pressure needed to maintain airway patency at any point in time and can accommodate a range of background states that affect airway collapsibility and hence CPAP pressure requirement including sedation, alcohol, airway inflammation, body position and sleep state.

Compumedics Limited has developed an APAP device (Somnilink SPAP based on the new algorithm technology of characterising breaths and determination of inspiratory flow limitation. The objectives of this new technology are to enable accurate detection of inspiratory intervals for irregular breathing patterns that are likely to occur during REM sleep, sleep onset and wakefulness as well as to provide correct characterisation of inspiratory flow limitation. These features could translate in delivery of superior treatment because of improved sensitivity and specificity of respiratory event detection and earlier pressure response to inspiratory flow limitation. Demonstration of superiority of the Somnilink SPAP device relative to existing APAP treatment devices will be subject of future clinical trials (beyond the scope of this protocol). An early clinical trial of a pre-production version of Somnilink SPAP with the pressure control algorithm identical to the production version established non-inferiority for AHI relative to a reference APAP (Resmed Autoset Spirit) with the differential AHI estimate of -0.91 [-2.80; 0.91] (Mean [95%CI]). The Somnilink SPAP device is now available as a production version (CE and TGA approved) and the purpose of the current study is to establish its non-inferiority compared to an existing APAP device (Resmed Autoset S8).

The treatment will be administered on the two nights of polysomnographic studies (PSG) by means of continuous air pressure delivery under the variable pressure levels determined by the APAP device to maintain the upper airway patency.

The population of adult patients newly diagnosed with OSA after undergoing a diagnostic PSG study in the sleep laboratory with no previous CPAP treatment experience and complying with the eligibility criteria (as outlined below) will be studied. ;


Study Design

Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Crossover Assignment, Masking: Double Blind (Subject, Caregiver, Investigator, Outcomes Assessor), Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT01210261
Study type Interventional
Source Compumedics Limited
Contact
Status Completed
Phase N/A
Start date May 2011
Completion date October 2011

See also
  Status Clinical Trial Phase
Terminated NCT03605329 - Evaluation of the Severity of Cardiovascular Autonomic Neuropathy in Type 1 Diabetic Patients With OSAS N/A
Completed NCT04912635 - Evaluation of a Health Dashboard Intervention to Improve Engagement With CPAP Therapy in PAP-Naïve Patients: Project Neo N/A
Not yet recruiting NCT05939934 - Impact of the Mandibular Advancement Device on Sleep Apnea During CPAP Withdrawal N/A
Enrolling by invitation NCT02290236 - Monitored Saturation Post-ICU N/A
Completed NCT02088723 - Testing the Elevation as Sleep Apnea Treatment N/A
Terminated NCT02269774 - Origin of Premature Atrial Beats Induced by Simulated Obstructive Sleep Apnea N/A
Completed NCT02261857 - 3D-Printed CPAP Masks for Children With Obstructive Sleep Apnea Early Phase 1
Completed NCT01181570 - Efficacy and Safety of Adalimumab in Patients With Psoriasis and Obstructive Sleep Apnea Phase 4
Completed NCT01943708 - Novel Auto-continuous Positive Airway Pressure (CPAP) Validation Phase 3
Completed NCT00273754 - The Effect of Caffeine on Postextubation Adverse Respiratory Events in Children With Obstructive Sleep Apnea (OSA). Phase 2
Recruiting NCT02166879 - Undetected Sleep Apnea in the Postanesthesia Acute Care Unit (PACU)
Recruiting NCT04963192 - Integrated Management of Chronic Respiratory Diseases N/A
Completed NCT05056766 - How Does the Clinical and Paraclinical Efficacy of an Oral Appliance Evolved According to Propulsion: Control With Each mm of Advancement
Completed NCT04846400 - Pilot Study of a Self-Supporting Nasopharyngeal Airway in Hypotonia N/A
Recruiting NCT04314492 - Intracapsular Tonsillectomy in the Treatment of Obstructive Sleep Apnea in Adults N/A
Completed NCT05175287 - OSA (oRisk of Obstructive Sleep Apnea and Traffic Accidents Among Bus Drivers in Ecuador: is There a Significant Association
Active, not recruiting NCT03431038 - Cross-sectional Study of Prevalence Rate of Abdominal Aortic Aneurysm in OSAHS Patients From BTCH N/A
Enrolling by invitation NCT03075787 - Cardiovascular Variability and Heart Rate Response Associated With Obstructive Sleep Apnea N/A
Completed NCT03300037 - HYpopnea and Apnea Detection and Treatment Performance of a New cardiOreSpiratory Holter Monitor N/A
Recruiting NCT06097949 - AcuPebble to Remotely Monitor Patients With OSA on CPAP Therapy