Clinical Trials Logo

Clinical Trial Summary

The use of electrocautery to incise the skin is still debated. Aim of the present study is to contribute at the use of electrocautery for skin incision as safe procedure both for patients and surgeons.


Clinical Trial Description

All patients observed between 2016 and 2021 at the Department of Surgical Sciences, Organ Transplantation, and Advanced Technologies of University of Catania and submitted to abdominal surgery in which the incision of the skin have been done by electrocautery, have been considered. Sex, age, kind of disease in relation to the organ affected and type of surgical procedure and related incision have been investigated. Patients with diabetes mellitus, coagulation disorders and those submitted to a treatment of steroids and anticoagulant; patients previously operated with scar in the site of the second operations, or with anemia or with active source of infection in any part of the body where excluded from the study. The ethical approval isn't necessary because is a retrospective study. All patients have express the oral informed consent to participate at this study. In this retrospective study was analyzed the skin incision that has been classified into laparotomic or laparoscopic, in elective or emergency surgery. The laparotomic included large (large midline as xipho-umbilical or umbilical pubic incision, subcostals or pararectal) and small (small midline no more than 7 cm, inguinal, McBurney) skin incisions. The laparoscopic on the opposite involve incisions from minimum of 1 cm or less for introduction of trocars, and a maximum of 10 cm to extract organ. The subcutaneous layer has been closed using an interrupted suture using Vycril®3-0 on the opposite the skin suture has been done using metallic clips. All patients have been submitted to general or spinal anesthesia. Antibiotic prophylaxis was done, following the guidelines related to the disease (5). Patients submitted to hernioplasty of laparoscopic cholecystectomy or any procedure in which the literature have reached a consensus any antibiotic treatment including the prophylaxis have not been done (5). The outcomes considered are wound infections, post-operative pain, healing time, cosmetic results. The post operative pain has been related to the administration of paracetamole 1 gr every 12 hours for the first 3 days. The healing time and cosmetic results have been evaluated both during the hospitalization or in the out patients clinics, after 10 from surgical procedure at moment of ablation of metallic clips, and/or 20 days after the surgical incision with final clinical evaluations of the scar. Finally considering the medical records and operative reports, patients were contacted 6 months later by phone by resident in surgery ask them to evaluate their scar. The patient was asks simple to define their scar as acceptable and consequently patient satisfied or not acceptable so patient not satisfied. We, also, consider the reported injury to surgeons or theater workers during the surgical procedure. Particularly we have reported the burns from hole in the gloves related to an absent respect of the isolated generator circuit All patients were treat an expert surgeon, that used the same technique for the incision skin. The skin incision has been done using the following rules: the cutting diathermy have been used to incise the skin. If bleeding comes from the dermis, the coagulation diathermy has been shortly used using the tip of the headpiece, without forceps. To incise the skin we have used a Valleylab force TX Medtronic Italy equipped with standard diathermy pen electrode, set on cutting mode for skin at 20 KHz sinusoidal current and on coagulation mode at K40 Hz both for skin and for deeper tissues (6). Electrosurgery works by electrons' handling on living tissue using an alternating current density sufficient to create heat within tissue cells to destroy them. It is mandatory to consider the mode of use electrosurgery. In the cutting mode, a continuous current produce extreme heat causing vaporization so the conversion of the cells into steam. When we use the electrosurgery unit into cutting mode for the skin the cells vaporize and the tissue is divided with a minimum devitalization, the thermal damage is minimal and it is not propagated to neighboring cells. Differently the coagulation mode that cause high thermal damage and necrosis of adjacent cells. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05744284
Study type Observational
Source University of Catania
Contact
Status Completed
Phase
Start date January 1, 2016
Completion date December 20, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT04802694 - The Effects of The Products Used In Nazogastric Tube Fixation N/A
Recruiting NCT05251753 - Evaluation of a Novel Sutureless Drain Securement Device N/A
Completed NCT05449600 - Thermotape High-adhesion Medical Tape Comparison Study N/A
Completed NCT05792306 - The Novel Electrolyzed Water Spray Treatment Discomfort, Redness and Swelling of the Skin Surrounding the Wound N/A
Not yet recruiting NCT06122402 - Effectiveness of Care Bundle in Preventing Medical Adhesive-Related Skin Injury Due to Central Venous Catheter Fixation in Children N/A
Recruiting NCT06192095 - Applying Liquid Skin Barrier Film to Prevent Skin Complications Around Indwelling Vascular Catheters in Pediatric Patients: a Randomized Controlled Trial N/A
Completed NCT05561946 - An Observational Study of Skin Reaction in Infants Using the Owlet Sock OSS 3.0