Comparison of the Success Rate of Intubation With Direct Laryngoscopy or Videolaryngoscopy in an Hemoptysis Simulated Situation on Human Cadaver Embalmed With Thiel's Method
Our study first aims to develope a realistic cadaver model of hemoptysis based on Thiel's embalmed cadavers. Secondly, participants will intubate the hemoptysis cadaver model with (a) the direct laryngoscopy with MacIntosh blade, (b) the videolaryngoscopy with McGrath XBlade and (c) the videolaryngoscopy with McGrath XBlade and a suction advance before the optic of the camera. We hypothesis that, in simulated hemoptysis on the Thiel's embalmed cadaver, the rate of failed intubation at first try will be different depending on the laryngoscope used.
For the simulation of hemoptysis, we will need to use the Thiel's embalmed cadaver, who's
realism is established, create a synthetic form of blood resembling real blood by its
viscosity and color for the simulation and elaborate the dynamic interface of the simulation
of hemoptysis. The quantity and way of administration of the blood through the trachea will
be tested to obtain a realistic hemoptysis as seen in supraglottic.
For the simulation, we will compare the efficiency of intubation, judged by the failure rate
of intubation on first try, for (a) the direct laryngoscopy with MacIntosh blade, (b) the
videolaryngoscopy with McGrath XBlade and (c) the videolaryngoscopy with McGrath XBlade with
the suction advanced before the camera. We will also measure the time to intubation, the
failure rate of intubation, the suction use and the difficulty of intubation as reported by
the participants.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT05535127 -
Sequential Strategy vs Palpation vs Routine Ultrasound for Detection of Cricothyroid Membrane
|
N/A | |
Not yet recruiting |
NCT05036460 -
Real-time Sonography in Detecting Inadvertent Esophageal Intubation Among Difficult Intubation Patients
|
N/A | |
Completed |
NCT05303948 -
Evaluation of Two Positions for Free Floating Tracheal Intubation in Weightlessness
|
N/A | |
Completed |
NCT06107751 -
Ramped and Sniffing Position for Cesarean Section Intubation.
|
N/A | |
Completed |
NCT04089540 -
New Intubation Method to Achieve Circulatory Stability and to Reduce Number of Intubation Attempts in Neonates
|
N/A | |
Completed |
NCT05522049 -
Videolaryngoscopic Intubation Using Macintosh vs.Hyperangulated Blades in Patients With Expected Difficult Intubation
|
N/A | |
Completed |
NCT03046966 -
Manikin To Patient Intubation: Does It Translate?
|
N/A | |
Not yet recruiting |
NCT05130645 -
Evaluation of Mandibular Mental Angle and Mandibular Profile Angle
|
||
Completed |
NCT06042829 -
Impact of Covid-19 Aerosol Box On Intubation Success Rate
|
N/A | |
Completed |
NCT06138119 -
The Impact of Gender Stereotypes on Fiberoptic Intubation Performance
|
N/A | |
Not yet recruiting |
NCT06115694 -
Comparison of Video Laryngoscopy With Rigid Stylet vs Video Laryngoscopy With the TCI Articulating Introducer for Endotracheal Intubation in Simulated Difficult Airways
|
N/A | |
Completed |
NCT05243758 -
Who is Rapid And Success? The Comparison Of Video Fiberscope And Video Laryngoscope
|
N/A | |
Completed |
NCT04833166 -
Comparing Full vs. Partial Glottis View Using CMAC D-Blade Video Laryngoscope in Simulated Cervical Injury Patient
|
N/A | |
Completed |
NCT03118596 -
Fibre-optic Guided Tracheal Intubation Through SADs
|
N/A | |
Recruiting |
NCT05680909 -
Evaluation of SaCo Videolaryngeal Mask Airway in Morbidly Obese
|
||
Recruiting |
NCT05429112 -
Flexible Tip Bougie vs Tube With Stylet for Intubation With a Videolaryngoscopy in ICU (VIDEOL-FLEXTIP)
|
N/A | |
Completed |
NCT05833347 -
Evaluation of Difficult Laryngoscopy With Ultrasonography in Pediatric Patients
|
||
Completed |
NCT05366582 -
Neural Integrity Monitor Electromyogram (NIM-EMG) Endotracheal Tube Intubation With Video Laryngoscope
|
N/A | |
Recruiting |
NCT06322719 -
Hyperangulated vs Macintosh Blades for Intubation With Videolaryngoscopy in ICU
|
N/A | |
Recruiting |
NCT06213389 -
Comparison of EzVision® Videolaryngoscope and Gum Elastic Bougie-Assisted Machintosh Laryngoscopy
|
N/A |