Cochlear implants (CIs) are well-established neuroprosthesis used to restore hearing for patients with partial or complete deafness. However, the audiological outcomes of these implants can vary widely, and one reason for this is suboptimal electrode placement. The gold standard for measuring electrode positions is computed tomography (CT) scans, but they are expensive and expose patients to additional radiation, which is especially harmful for children. This study investigates an alternative approach using impedance telemetry data to estimate electrode positions without exposing patients to radiation. For this purpose, an extended telemetry version of a CE-certified cochlear implant software is used. The advanced impedance telemetry software can measure impedance subcomponents with improved measurement resolution that could be used for more accurate estimation of electrode insertion depth using specially designed estimation software. Ultimately, the investigators want to demonstrate the potential to improve audiological outcomes of cochlear implant recipients without exposing them to additional radiation.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT06223724
Study type Observational
Source Insel Gruppe AG, University Hospital Bern
Contact Stephan Schraivogel, MSc
Phone +41 31 632 76 15
Email stephan.schraivogel@unibe.ch
Status Recruiting
Phase
Start date October 25, 2023
Completion date October 1, 2024

See also
  Status Clinical Trial Phase
Completed NCT00023036 - Clinical and Genetic Analysis of Enlarged Vestibular Aqueducts
Completed NCT03746613 - Clinal Evaluation of Navigation Based Functional Ear Surgery Using Image Guided and Robotically Assisted Techniques N/A
Recruiting NCT05568329 - Appreciation for Music Processed by Hearing Aids N/A
Withdrawn NCT05061758 - A Trial of LY3056480 in Patients With SNLH Phase 2
Completed NCT01434446 - The Effect of Sound Stimulation on Hearing Ability N/A
Completed NCT03212924 - Listening Effort in Cochlear Implant Users N/A
Recruiting NCT06053190 - Effects of Clear Speech on Listening Effort and Memory in Sentence Processing N/A
Completed NCT03718975 - Quality Control of CE-Certified Phonak Hearing Aids - 2018_28 N/A
Completed NCT06025097 - Intra-Tympanic Steroid With PRP Combination in Sensorineural Hearing Loss and Tinnitus. Early Phase 1
Recruiting NCT04102215 - The Efficacy of a Minimally Invasive Direct Cochlear Access Via the HEARO Procedure N/A
Recruiting NCT04108598 - The SeaSHeL National Prospective Cohort Study
Active, not recruiting NCT04750642 - Cochlear Implant With Dexamethasone Eluting Electrode Array N/A
Completed NCT04120116 - FX-322 in Adults With Stable Sensorineural Hearing Loss Phase 2
Completed NCT02005822 - Congenital Cytomegalovirus: Efficacy of Antiviral Treatment Phase 3
Suspended NCT02616172 - Autologous Bone Marrow Harvest and Transplant for Sensorineural Hearing Loss Phase 1/Phase 2
Completed NCT02259595 - Study to Determine the Safety, Tolerability, and Pharmacokinetic Profile of HPN-07 and HPN-07 Plus NAC Phase 1
Unknown status NCT01902914 - Effectiveness of P02 Digital Hearing Aids Phase 1/Phase 2
Completed NCT00589511 - Nucleus Freedom Cochlear Implant System Pediatric Post-approval Study N/A
Completed NCT03288753 - Comparison Between Neuro 1 and Neuro 2 Cochlear Implant Speech Processors N/A
Completed NCT04462198 - Phase I/IIa Study Evaluating Safety and Efficacy of an Intratympanic Dose of PIPE-505 in Subjects With Hearing Loss Phase 1/Phase 2