Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT03260374
Other study ID # OMCI
Secondary ID
Status Not yet recruiting
Phase N/A
First received August 20, 2017
Last updated August 22, 2017
Start date December 1, 2017
Est. completion date December 30, 2019

Study information

Verified date August 2017
Source Assiut University
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

One of the main factors affecting the ability to maximize the full potential of a cochlear implant is an accurate map.The goal of mapping is to enable cochlear implant recipients to perceive a desired range of acoustic signals. The process includes programming of the minimum and the maximum stimulation levels that are based on subjective measurements of thresholds and the most comfortable level . The use of objective measures in the CI process has greatly contributed to the definition of the dynamic field, as they provide specific values that serve as the basis for the start of the mapping process, especially in cases of infants and young children. Some examples of these measures are electrically evoked stapedius reflex threshold , neural response telemetry , brainstem auditory evoked potential , and P300, among others.


Description:

In adult Cochlear implant users, programming is a relatively straightforward task as psychophysical measurements can be explained, and patients quickly understand the link between the mapping process and the output of their system . In young children or infants, the mapping process is more complex, especially comfort levels. Setting the threshold level requires the child to respond to the presence or the absence of a sound. Although the same techniques are used in setting the comfort level, the child is now required to make a judgment about the sound beyond its simple presence or absence. Young children often lack the attention span, patience, and cognitive and language skills necessary to perform these tasks with good reliability and repeatability .The use of objective measures in the CI process has greatly contributed to the definition of the dynamic field, as they provide specific values that serve as the basis for the start of the mapping process, especially in cases of infants and young children. Some examples of these measures are electrically evoked stapedius reflex threshold , neural response telemetry , brainstem auditory evoked potential , and P300, among others.The electrically evoked compound action potentials, which are closely related to the electrically evoked brainstem responses, would also show a similar correlation with the behavioral threshold . Determining threshold levels requires subjective responses to a series of sophisticated psychophysical percepts. This is often difficult for cochlear implant patients. However, the neural response telemetry system renders possible the measurement of the compound action potential threshold . Electric stapedial reflex threshold measurements are performed using the same software platform and electrical stimulus utilized for fitting the cochlear implant . Thus, stimulus parameters, including pulse duration and repetition rate, can be identical to those used to obtain behavioral judgments for psychophysical levels .For most implant recipients , even the first introduction of electric stimulation from a cochlear implant evokes activity in the auditory brainstem , which can be measured as clear electric auditory brain stem response waveforms . Therefore this test can be used in the functional evaluation of the auditory system between the time of initial implant activation and after chronic cochlear implant use.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 30
Est. completion date December 30, 2019
Est. primary completion date August 31, 2019
Accepts healthy volunteers No
Gender All
Age group 2 Years to 6 Years
Eligibility Inclusion Criteria:

- children implanted with Medel multichannel cochlear implant

Exclusion Criteria:

- • Any middle ear problem

- Any technical problems with the cochlear implant device

Study Design


Intervention

Device:
Electric compound action potential
The electrically evoked compound action potentials, which are closely related to the electrically evoked brainstem responses, would also show a similar correlation with the behavioral threshold. Determining threshold levels requires subjective responses to a series of sophisticated psychophysical percepts. This is often difficult for cochlear implant patients. However, the neural response telemetry system renders possible the measurement of the compound action potential threshold .
electric stapedial reflex threshold
electric stapedial reflex threshold measurements are performed using the same software platform and electrical stimulus utilized for fitting the cochlear implant . Thus, stimulus parameters, including pulse duration and repetition rate, can be identical to those used to obtain behavioral judgments for psychophysical levels
electric auditory brain stem response
For most implant recipients , even the first introduction of electric stimulation from a cochlear implant evokes activity in the auditory brainstem , which can be measured as clear electric auditory brain stem response waveforms . Therefore the electric auditory brain stem response test can be used in the functional evaluation of the auditory system between the time of initial implant activation and after chronic cochlear implant use

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Assiut University

Outcome

Type Measure Description Time frame Safety issue
Primary Arabic language test Speech and language assessment in children with cochlear implant 2 years
See also
  Status Clinical Trial Phase
Completed NCT00023036 - Clinical and Genetic Analysis of Enlarged Vestibular Aqueducts
Completed NCT03746613 - Clinal Evaluation of Navigation Based Functional Ear Surgery Using Image Guided and Robotically Assisted Techniques N/A
Recruiting NCT05568329 - Appreciation for Music Processed by Hearing Aids N/A
Withdrawn NCT05061758 - A Trial of LY3056480 in Patients With SNLH Phase 2
Completed NCT01434446 - The Effect of Sound Stimulation on Hearing Ability N/A
Completed NCT03212924 - Listening Effort in Cochlear Implant Users N/A
Recruiting NCT06053190 - Effects of Clear Speech on Listening Effort and Memory in Sentence Processing N/A
Completed NCT03718975 - Quality Control of CE-Certified Phonak Hearing Aids - 2018_28 N/A
Completed NCT06025097 - Intra-Tympanic Steroid With PRP Combination in Sensorineural Hearing Loss and Tinnitus. Early Phase 1
Recruiting NCT04102215 - The Efficacy of a Minimally Invasive Direct Cochlear Access Via the HEARO Procedure N/A
Recruiting NCT04108598 - The SeaSHeL National Prospective Cohort Study
Active, not recruiting NCT04750642 - Cochlear Implant With Dexamethasone Eluting Electrode Array N/A
Completed NCT04120116 - FX-322 in Adults With Stable Sensorineural Hearing Loss Phase 2
Recruiting NCT06223724 - Status Telemetry for Cochlear Implantations
Completed NCT02005822 - Congenital Cytomegalovirus: Efficacy of Antiviral Treatment Phase 3
Suspended NCT02616172 - Autologous Bone Marrow Harvest and Transplant for Sensorineural Hearing Loss Phase 1/Phase 2
Completed NCT02259595 - Study to Determine the Safety, Tolerability, and Pharmacokinetic Profile of HPN-07 and HPN-07 Plus NAC Phase 1
Unknown status NCT01902914 - Effectiveness of P02 Digital Hearing Aids Phase 1/Phase 2
Completed NCT00589511 - Nucleus Freedom Cochlear Implant System Pediatric Post-approval Study N/A
Completed NCT03288753 - Comparison Between Neuro 1 and Neuro 2 Cochlear Implant Speech Processors N/A