Clinical Trials Logo

Clinical Trial Summary

Alteration of evoked potentials is described in cases with using inhalation anaesthetics. Muscle relaxants are contraindicated in case of motor evoked potentials except for initial dose for intubation of the patient. Dominant anaesthetic method for procedures with measuring motor evoked potentials is total intravenous anaesthesia (TIVA). Bispectral index (BIS) monitoring is one of the possible options for comprehensive monitoring of the depth of general anaesthesia. It helps to optimize the management of anaesthesia, so it reduces the risk of perioperative awakenings due to shallow anaesthesia or inadequate depth of anaesthesia associated with the risk of cognitive dysfunction, as well as investigators expect worse interpretation of motor evoked potentials. At the same time, it shortens the time to wake up from general anaesthesia after hours-long surgery. BIS monitoring allows optimizing the depth of anaesthesia and leads to improve quality and interpretation of motor evoked potentials. The depth of TIVA managed by BIS affects the reproducibility of motor evoked potentials.


Clinical Trial Description

SCOL study is designed as a prospective observational study. We will monitor patients with scoliosis suitable for TIVA with BIS monitoring after the approval by the ethical committee of the University Hospital Brno and the Faculty of Medicine of Masaryk University in Brno, Czech Republic. The study period is planned from 1st September 2020 to 31st December 2024. Anaesthesia will be maintained following standardized local protocol for scoliosis surgery, include preoperative preparation and premedication. General anaesthesia will be performed in TIVA mode,combining propofol and remifentanil with titration to the target BIS value. Motor evoked potentials will be measured and evaluated by members of operating team perioperatively. The evocation of reproducible motor evoked potential and the actual value of amplitude and latency at different BIS levels (40 - 60) will be monitored. Motor evoked potentials (MEP) reproducibility will be based on standardized orthopaedic practice, according to the amplitude, latency of the MEP. The reproducibility will be monitored in defined surgery phases: before skin incision at the different BIS levels, next after screw application, rod applications, after distraction and the last one before wound suturing. At the same time, the BIS value is recorded. In addition to the MEP reproducibility, investigators will measure the amplitude and latency value. These parameters and actual BIS value will be monitored in each patient after the recovery from neuromuscular blockade (TOF ratio value above 90%) to eliminate the influence of neuromuscular blockade on neurophysiology monitoring. Due to individual variability in the MEP latency and amplitude in these patients, the initial MEP value will be set as the default (100%), and other values will be expressed as a percentage. Other monitored parameters in this study will be blood loss, blood derivates and transfusion products administered to the patient in first 24 hours after surgery, the time between the end of the surgery and extubation, neurological complications, number of surgical revisions and a total length of hospitalization. The annual number of scoliosis operations at the University hospital Brno is around 130 patients. It is the largest surgery centre in Central Europe. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04423146
Study type Observational
Source Brno University Hospital
Contact Martina Kosinova, MD., Ph.D
Phone 532234692
Email kosinova.martina@fnbrno.cz
Status Recruiting
Phase
Start date September 1, 2020
Completion date January 1, 2025

See also
  Status Clinical Trial Phase
Recruiting NCT04848376 - Post-Market Clinical Follow-up Study of A-SPINE's Products
Recruiting NCT05944393 - Erector Spine Plane (ESP) Block for Analgesia in Pediatric Scoliosis Surgery N/A
Recruiting NCT05888038 - Virtual Reality's Effect on Decreasing Pain and Subsequent Opioid Use in Pediatric Patients in the Post-Operative Period Following Scoliosis Repair N/A
Completed NCT02558985 - Pulmonary Compliance Changes During Manipulation of Early Onset Scoliosis and Cast Application
Completed NCT02413788 - Impact of Aerobic Training and Combined in Inflammatory Markers in Patients With Adolescent Idiopathic Scoliosis N/A
Completed NCT02531945 - Evaluation of the Surface Topography for Monitoring Scoliosis Patients Aged 10-13 Years N/A
Completed NCT02890654 - Scoliosis and Quality of Life of Adolescents
Completed NCT02609009 - Back Pain and Spinal Manipulation in Adolescent Scoliosis N/A
Terminated NCT02134704 - MOUVSCO: Kinematic Analysis of the Trunk in Patients With Moderate Scoliosis N/A
Completed NCT02285621 - Validation of a New Generation of Optimized Orthoses for Personalized Treatment of Adolescent Idiopathic Scoliosis N/A
Withdrawn NCT00768313 - Phase IV Comparing Rods of Yield Strengths to Correct Adolescent Idiopathic Scoliosis. Phase 4
Completed NCT00155545 - Influence of Leg Length Discrepancy on the Spinal Shape and Biomechanics in Functional and Idiopathic Scoliosis Patients Phase 1
Completed NCT00154505 - Effects of Lateral Trunk Support on Spinal Alignment in Spinal Cord Injured Persons Phase 1
Completed NCT00320619 - Epsilon-Aminocaproaic Acid to Reduce the Need for Blood Transfusions During and Following Spine Surgery N/A
Completed NCT00273598 - Comparing Two Instrumentation Systems for the Treatment of Adolescent Scoliosis Phase 2
Completed NCT03135665 - Using Radiation-free Ultrasound for Screening Scoliosis Among School Children in Hong Kong to Reduce Unnecessary X-ray Exposure N/A
Completed NCT03814239 - Blood and Fluid Management During Scoliosis Surgery
Withdrawn NCT02058238 - ADDRESS - Adult Deformity Robotic vs. Freehand Surgery to Correct Spinal Deformity
Completed NCT02904421 - 6 Years Study on Changes in Bone Quality, Bone Turnover and Curve Severity in AIS With and Without Calcium and Vit-D Supplementation
Completed NCT02581358 - Use of the Scolioscan for Quantitative Evaluation of Spinal Deformity - A Validity Study on Patients With Scoliosis N/A